Wireless CCD Scanner - MS912 - User’s Manual Version 1.0 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
Table of Contents Table of Contents ...................................................................................................................... i Chapter 1................................................................................................................................... 1 Overview ................................................................................................................................... 1 Package Contents ....................................................
Chapter 1 Overview Introducing the MS912 The MS912 scanner combines miniaturized barcode scan engine and wireless technology to provide the best value in a wireless handheld scanner. Featuring lightweight and ease-of-use, the MS912 scanner ensures the productivity and mobility of your business application. The MS912 is the smallest wireless scanners in the market and is compatible with all major OS on the nowadays popular smartphones and tablet PCs via both HID and SPP profiles.
Package Contents Please make sure the following contents are in the MS912 box. If something is missing or damaged, please contact your Unitech representative. MS912 scanner Product Resource CD Quick Guide USB Charging Cable Hand Strap Quick Connection Card Note: 1. The scanner’s default power off (idle mode) time is 3 minutes. 2. Please charge scanner for at least 2 hours prior to initial use.
Chapter 2 Installation and Connection Connecting (Pairing) the Scanner to a Host PC Please make sure your PC or Smartphone has a built-in wireless adaptor; the MS912 supports both HID and SPP wireless profiles.
9. c. We suggest using 4 numbers. Once you have entered the pin code on the Host device, you need to set up the pin code on the MS912 to match. a. With the MS912, scan the Pincode Start barcode below. Pincode Start b. Refer to the barcode table below, and scan the same numbers that you used as the pin code on your Host device. For example, if your pin code is “241657”, scan [2] – [4] – [1] – [6] – [5] – [7] in sequential order: c. Scan the [Enter] barcode below: Enter d.
you to type in data]. b. Scan a number bar code from this manual. c. That number should appear on your Host device in the application you opened. d. If not, please scan [Disconnect] barcode below and repeat steps 1 to 9 above. Note. To disconnect the scanner from the host or to switch the wireless profile from one to another, please scan the [Disconnect] barcode: Disconnect After scanning the [Disconnect] barcode, the MS912 will emit 3 beeps. 5 Unitech electronics co., ltd. 5F., No.135, Ln.
Connecting via Human Interface Device (HID) Mode (Non-Pincode) 1. Press the trigger for 1 second to activate the scanner. 2. Scan [DISCONNECT] Disconnect 3. Scan [BT mode - HID non-pincode]; the scanner will emit 8 beeps. BT mode - HID non-pincode .E040$ 4. Search for the scanner nearby around by using the Bluetooth module of your host PC. 5. Click Add a device to search for a wireless scanner nearby around. 6 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist.
6. Click Wireless Scanner to add to the computer. Then, click Next. 7. In this step, the computer is connecting the wireless scanner. When it connects, click Next. 8. Click Pair without using a code. Then, click Next. 7 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
9. Then, click Close. 10. You will see a message telling that the device driver software is installed successfully. 11. The scanner will beep twice to verify the connection. *Note: In this mode, the scanner is recognized by the host as a mouse (pointing device). If your host fails to find it, please try [Connecting via Human Interface Device (HID) Mode] instead. Connecting via Serial Port Profile (SPP) Mode 1. 2. 3. Turn on the wireless device on your host (PC, Smartphone, or Tablet).
Mode. 2. Install Bluetooth Connect.apk, which is available on CD. Note: Before installation, enable ‘Unknown Sources” in Android Authority. 3. Enable [BluetoothConnect] in the Language & Keyboard setting window and choose [BluetoothConnect] as Input Method. 4. Click [Connect] and you will be able to connect the scanner. Note: BluetoothConnect needs to be installed only when you have NO wireless input application on your Android device. Android 2.x devices can work with MS912 in the SPP mode ONLY.
Scan the Default Wireless ID barcode. .B022$ STEP 2 Scan the Set Wireless ID barcode. .B023$ STEP 3 Scan 7 alphanumeric characters from Full ASCII Chart of Appendix A. STEP 4 Scan the Set Wireless ID barcode. .B023$ STEP 5 Scan a desired BT mode barcode (SPP or HID) to connect. *Note: 1. If you have connected the scanner with the host BEFORE customizing your Bluetooth device name, please remove the device and create a new connection to make sure device name is refreshed.
Green LED Red LED Beeper Power Off or Standby - - - Charging - Solid - - Disconnected or Discoverable Flash - - - Initializing Flash Flash 1 long beep - Power Up - - 1 long beep - Flash - 1 beep - 1 Flash - 1 beep - Successful Connection - - 2 beeps - Unsuccessful Pincode Setup - Flash 3 short beeps Low Power - Flash 1 Flash - Scanner Barcode scanning w/o proper connection Successful barcode scan Out of range Remark See Power Off Timeout Scan [Pincode Stop
12 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
Chapter 3 Specification MS912 Performance/Optical Image Sensor Linear CMOS sensor Light Source 625nm Visible Red LED Max. Resolution 5 mil (0.
Operating Temperature 0°C to 40°C Storage Temperature -20°C to 60°C Relative Humidity 20% to 85% non-condensing Drop Test 1.5M Communication Range 10M (line of sight) Host Interface supported Mini USB Interface/Profile SPP, HID Wireless Class Wireless Class 2 Mechanical Housing Material ABS Dimensions L65 x W24 x H18mm / 2.6 x 0.9 x 0.7in Weight 24.6g / 0.9oz Regulation Approvals FCC Class B, CE Accessories Mini USB cable, Hand Strap, Tools CD 14 Unitech electronics co., ltd. 5F., No.
Chapter 4 User Preferences Setup Procedures This chapter describes the user-configurable settings for the MS912 and provides the programming bar codes for selecting these features for the scanner. To configure your MS912 scanner: 1. Locate the appropriate feature setting listed in the following pages. 2. Set feature values by scanning single barcodes or short barcode sequences. 3. The MS912 will beep to confirm a successful scan and will store the new setting in the scanner’s memory. 40B Min. Length / Max.
1. 2. 3. 4. Maximum length of 20 Go To "Group 4" Scan "MAX LENGTH" to enter maximum length setting. Scan "2" and "0" to select length 20. (Full ASCII Chart of Appendix A) Scan "MAX LENGTH" to end maximum Length Setting.
ACCURACY ADJUSTMENT ACCURACY ADJUSTMENT Accuracy Adjustment assures a more reliable decoded output. Enabling the feature and setting a number from 1 to 9 subjects the decoded output a higher standard of accuracy. The higher the number, the greater the accuracy. 17 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
SETTING PROCEDURE: 1. Scan ACCURACY ADJUSTMENT. 2. Scan one digit (1~9) from barcode menu above. 3. Scan ACCURACY ADJUSTMENT. RESET NOTES: 1. The scanner will beep three times as reminder that a setting is not yet complete. 2. If you make a mistake, forget a step, etc., scan RESET to start again. FORMAT: {Preamble} {Code ID}{Bar Code }{Postamble} NOTES: 1. 2. 3. A PREAMBLE is a string of up to 16 characters added to the beginning of a scanned barcode.
1.1 1.2 1.3 Beep tune: BEEP LOW -- HIGH Caps Lock Mode: CAPSLOCK ON (FIXED). Reading Mode: CONTINUOUS AUTO OFF. 2. SETTING PROCEDURE: 1.1 Scan BEEP LOW – HIGH. (GROUP 3). 1.2 Scan CAPSLOCK ON (FIXED). (GROUP 3) 1.3 Scan CONTINUOUS AUTO OFF. (GROUP 2) 3. All parameters will be converted to alphanumeric characters and shown on the monitor. 19 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.
4. Print the results shown on the monitor as bar codes with a bar code printer. The bar codes should be in the Code 39 symbology. 5. Scan these labels with any of the scanners you wish to configure similarly to the master. Be sure to scan from the first row to the second row and so on sequentially, top to bottom. CORRECT SETTING 41B WRONG SETTING Wrong Setting: The string “…" consists of 4 Dots, located at the beginning of second rows. Do not break the "…" into multiple strings.
You can adjust the length of the dumped strings by combining multiple strings into one or breaking one string into multiple strings. The following strings have the same effect as the dumped string listed above: You cannot delete any character from or add any character to the strings and the first three characters ("...") must be present in the first string. All characters in dumped strings are uppercase. If you see lowercase characters in dumped strings, change them to uppercase.
22 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
Chapter 5 Features of Memory Version . A007$ CHECK VERSION BATCH MODE Being out of range, the scanner will temporarily keep scanned data in its memory buffer (2K RAM) until the buffer is full. The scanner will send all stored data back to the host after getting in range. *Note: Batch Mode will not function when Memory Mode is enabled, or no connection is made beforehand.
MEMORY MODE . R001$ ENABLE MEMORY . R002$ DISABLE MEMORY Once enabled, the scanner will stop sending data via Bluetooth and start storing data into the internal flash disk. (2MB) Delete Last Record/Clear All Record . R005$ DELETE LAST RECORD . R004$ CLEAR ALL RECORD OUTPUT DATA . R003$ OUTPUT DATA Data Output Method . R014$ WIRELESS 24 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.
. R013$ USB-VCP To output stored data via Wireless, please do the following: 1. Scan [WIRELESS] 2. Scan [OUTPUT DATA] To output stored data via USB-VCP, please do the following: 1. Install VCP driver (available on CD) 2. Connect the scanner & host with USB cable 3. Scan [USB-VCP] 4. Save data as * .csv by “Covert to CSV.exe” (available on CD) DATA FORMAT . R011$ DATA FORMAT The default Data Format is
26 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
DATE & TIME SETUP . R006$ SET DATE Example: To set Date to 2012-08-01 (Year-Month-Day): 1. Scan [Set Date] 2. Scan [1], [2], [0], [8], [0], [1] on page 39. 3. Scan [Set Date] . R007$ SET TIME Example: To set Time to 08:10:30 am (Hr:Min:Sec) 1. Scan [Set Time] 2. Scan [0], [8], [1], [0], [3], [0] on page 39. 3. Scan [Set Time] * To avoid Time and Date being reset to factory default due to running out of battery, please fully charge the scanner for at least 3 hours before use. DATE FORMAT .
The default Date Format is DD/MM/YYYY (Code = 09), below is full list of available formats and their setup codes: Code 01 02 03 04 05 06 07 08 Item DD-MM-YYYY MM-DD-YYYY DD-MM-YY MM-DD-YY YYYY-MM-DD YY-MM-DD DD-MM MM-DD Code 09 10 11 12 13 14 15 16 Item DD/MM/YYYY MM/DD/YYYY DD/MM/YY MM/DD/YY YYYY/MM/DD YY/MM/DD DD/MM MM/DD Example: To set Date Format to MM/DD/YY (Code =12) 1. Scan [Date Format] 2. Scan [1], [2] on page 39. 3. Scan [Date Format] TIME FORMAT .
Appendix A Setup Chart Quick Setup Sheet scanner Mode Beep Terminator UPC-E Scan Code 29 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
30 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
Beeps and Delays Group 1 Interblock Delay Beep Tone 2.7KHz 2.1KHz Intercharacter Delay .F014$ .F021$ BEEP HIGH BEEP HIGH – LOW .F016$ BEEP HIGH--LOW .F020$ .F013$ BEEP LOW – HIGH BEEP MEDIUM .F015$ BEEP LOW--HIGH .F017$ BEEP LOW 31 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
Keyboard Wedge Settings Group 2 Language(For PC/XT,AT) Function Code Caps-Lock Use number keypad digits 32 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
Scanner Port: Group 3 Terminator Scanning Mode Data Length (Two Dghts) Send Preamble /postamble Code ID Label Type 33 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
Define Code ID Group 3 Define Code ID 34 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
Code 39 / Full ASCII Code Group 4 35 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
2 of 5 Group 5 I 2of5 (ITF) 36 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
2 of 5 / Code 32 Group 6 S 2of5 / China Postal Code (Toshiba Code) Code 32 (Italian Pharmacy) 37 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
EAN 128 Group 7 Telepen UCC / EAN 128 Define the EAN 128 Fields Separtor Note: If EAN 128 be disabled, the EAN 128 labels will be decoded as Code 128 Scan a ASCII code in full ASCII code chart to select a new fields separator 38 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
Code 128/ Code 93 / MSI Code Group 8 Code 128 Code 93 MSI / Plessey Code Numeric Barcode 39 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
SETTING PROCEDURE MIN / MAX LENGTH STEP 1 - Scan: MIN LENGTH/ MAX LENGTH STEP 2 - Scan: Two digits from Appendix. STEP 3 - Scan: MIN LENGTH/ MAX LENGTH Please note that when Min Length and / or Max Length are enabled, the scanner will only read bar codes that fall into those length parameters. Bar codes shorter or longer than specified will not be read. The default lengths for these are indicated in parentheses under the Min and Max bar codes for each symbology. 40 Unitech electronics co., ltd. 5F., No.
Code 11 / Codabar Group 9 Code 11 Codabar 41 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
UPC / EAN Code Group 10 UPC-A UPC-E 42 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
UPC / EAN Code Group 11 EAN-13 EAN-8 43 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
Supplement Code Group 12 MATRIX 2 Of 5 Group 13 Supplement Code 44 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
ATA Group 14 UK PLESSY CODE GROUP 15 45 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
Full ASCII Chart (Characters in parentheses represent Code 39 bar code printing) 46 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
47 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
48 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
Function Codes for PC 49 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
For UK Keyboard Special Character Note: *1 "Alt(left)Make" is programmed. Please scan "Alt(left)Break" to resume barcode setting. *2. "Shift(left)Make" is programmed. Please scan "Shift(left)Break" to resume barcode setting. *3. "Ctrl(left)Make" is programmed. Please scan "Ctrl(left)Break" to resume barcode setting. 50 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
Barcode Chart 51 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
. A007$ CHECK VERSION MEMORY MODE . R001$ ENABLE MEMORY . R002$ DISABLE MEMORY Delete Last Record/Clear All Record . R005$ DELETE LAST RECORD . R004$ CLEAR ALL RECORD 52 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
OUTPUT DATA . R003$ OUTPUT DATA Data Output Method . R014$ WIRELESS . R013$ USB-VCP . R011$ FIELD SEPARATOR DATE & TIME SETUP . R006$ SET DATE 53 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
. R007$ SET TIME DATE FORMAT . R008$ DATE FORMAT TIME FORMAT . R009$ TIME FORMAT 54 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
Appendix B Examples of Connection to Android and iOS Smartphones BluetoothConnect needs to be installed only when you have NO wireless input application on your Android device. Android 2.x devices can work with MS912 in the SPP mode ONLY. The SPP mode or/and the HID mode are not definitely compatible with each version of Android OS, and thus depends on the Android-based hardware specifications defined by the Android device manufacturers. U U Smartphone Connection (Android) 1.
4. Click the Menu button to enable the settings menu. 5. Click [Enable Input Method] and enable [BluetoothConnect] in the Language & Keyboard setting window. 56 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
6. Press and hold the “Input method” icon on the panel to enable Input method menu and select BluetoothConnect. 7. Now enable your wireless scanner by pressing the button for 2 seconds until a long beep. 8. Scan [BT mode - SPP] configuration barcode. It can be found on the quick start guide or quick connection card. 57 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
9. Click [Pairing Devices] on the setting menu and the device will prompt you to enter the Bluetooth settings window. 10. Click [Scan for devices] on the Bluetooth settings window. Click [Wireless Scanner] to pair with your wireless scanner. 58 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
11. The default pairing code is 1234. After successful pairing, the description under Wireless Scanner will be “Paired but not connected”. 12. Get back to BluetoothConnect, enable setting menu and click [Connect to Barcode Reader]. The scanner will beep twice to verify the successful connection. 59 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
13. Now you will be able to transfer barcode data onto your mobile device. Smartphone/ Tablet PC Connection (iOS) 1. 2. Press the scanner until a long beep sound to activate the scanner. Scan [BT mode - HID] configuration barcode. It can be found on the quick start guide or quick connection card. 60 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
3. Go to General Setting and turn on Bluetooth. 4. On the discovered device list, click [Wireless Scanner] to pair with your wireless scanner. The Bluetooth application will prompt you to enter a random pincode. 61 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
5. Please enter the pincode according to the procedures in the Pincode Setup section on the quick start guide or quick connection card. 62 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
6. The scanner will beep twice to verify the successful connection. And on the discovered device list, it will show the scanner is “connected”. 7. Now you can input any scanned barcode data onto your Note or other applications. Getting Connected without Pincode Secure Simple Pairing (SSP), supported by Bluetooth 2.1 orabove, allows you to pair with iOS without pincode. Please scan [Enable SSP], as shown left, before entering the pairing procedure of [BT mode - HID]. .E049$ 63 Unitech electronics co.
Touch Keyboard To toggle iPhone/iPad Touch Keyboard, please either scan below barcode or simply double-click the trigger. ENABLE iOS HOTKEY .E047$ DISABLE iOS HOTKEY .E048 $ 64 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.
Appendix C Worldwide Support Unitech’s professional support team is available to quickly answer questions or technical-related issues. Should an equipment problem occur, please contact the nearest Unitech regional service representative.
Regulatory Compliance Statements FCC Warning Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference with radio communications.
FCC Label Statement This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Canadian Compliance Statement This Class B Digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
TaiwanNCC Warning Statement 低功率電波輻射性電機管理辦法 第十二條: 經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自變更 頻率、加大功率或變更原設計之特性及功能。 第十四條: 低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時,應 立即停用,並改善至無干擾時方得繼續使用。低功率射頻電機需忍受合法通信或工業、科學及醫 療用電波輻射性電機設備之干擾。 68 Unitech electronics co., ltd. 5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.) Tel: + 886 2 89121122 Fax: +886 2 89121810 website: www.ute.