BT CCD Scanner - FCC ID: HLEMS340BT - sUser's Manual Version 1.1 © 2016 unitech Electronics Co., Ltd. All rights reserved. unitech is a registered trademark of unitech Electronics Co.
Change Log. Date Change Description Version 2016/1/11 first published version 1.0 2016/1/22 Add 1.4.2 Installing the battery 1.1 © 2016 unitech Electronics Co., Ltd. All rights reserved. unitech is a registered trademark of unitech Electronics Co.
Preface About This Manual Thank you for purchasing the unitech product. This manual explains how to install, operate and maintain our product. No part of this publication may be reproduced or used in any form, or by any electrical or mechanical means, such as photocopying, recording, or information storage and retrieval systems, without permission in writing from the manufacturer. The material in this manual is subject to change without notice.
1. 2. 3. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This device complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. To maintain compliance with FCC RF exposure requirements, avoid direct contact to the transmitting antenna during transmitting.
European Conformity Statement unitech Electronics co., Ltd herewith declares that the unitech product is in compliance with the essential requirements and all other provisions of the R&TTE 1999/5/EC directive, the EMC 2004/108/EC directive and the Low Voltage 2006/95/EC directive. The declaration of conformity is available for download at : https://portal.unitech.
Taiwan NCC Warning Statement 交通部電信總局低功率電波輻射性電機管理辦法 第十二條:經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者 均不得擅自變更頻率、加大功率或變更原設計之特性及功能。 第十四條:低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有 干擾現象時,應立即停用,並改善至無干擾時方得繼續使用。 低功率射頻電機需忍受合法通信或工業、科學及醫療用電波輻射性電機設備 之干擾。 注意事項: 1. 使用過度恐傷害視力。 2. 使用30分鐘請休息10分鐘;2歲以下幼兒不看螢幕,2歲以上每天看螢幕不要超過 1小時。 iv © 2016 unitech Electronics Co., Ltd. All rights reserved. unitech is a registered trademark of unitech Electronics Co., Ltd.
Laser Information The unitech product is certified in the U.S. to conform to the requirements of DHHS/CDRH 21CFR Subchapter J and to the requirements of IEC 825-1. Class II and Class 2 products are not considered to be hazardous. The unitech product contains internally a Visible Laser Diode (VLD) whose emissions do not exceed the maximum limits as set forth in the above regulations.
Battery Notice 1. To guarantee optimal performance, it is recommended that rechargeable batteries be replaced every year, or after 500 charging cycles are completed. It is normal for the battery to balloon or expand after one year or 500 cycles. Although it does not cause damage, it cannot be used again and must be disposed of according to the location's safe battery disposal procedures. 2. If a battery performance decreases more than 20%, the battery is at the end of its life cycle.
CAUTION! RISK OF EXPLOSION IF BATTERY IS REPLACED INCORRECTLY. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.. 如果更換不正確之電池行事會有爆炸的風險 請依製造商說明書處理用過之電池 如果更换不正确之电池行事会有爆炸的风险 请依制造商说明书处理用过之电池 Battery charge notice It is important to consider temperature when the battery pack is charging. Charging is most efficient at normal room temperature or in a slightly cooler environment. It is essential that batteries are charged within the stated range of 0°C to 40°C.
Adapter Notice 1. 2. 3. 4. Please do not leave the power adapter in the socket when it is not connected to your unitech product for charging. Please remove the power adapter when the battery is fully recharged. The bundled power adapter that comes with your unitech product is not meant to be used outdoors. An adapter exposed to water or rain, or a very humid environment can cause damage to both the adapter and the product.
Worldwide Support unitech’s professional support team is available to quickly answer questions or assist with technical-related issues. Should an equipment problem occur, please contact the nearest unitech regional service representative. For complete contact information please visit the Web sites listed below: Taipei, Taiwan – Headquarters Europe Tel: +886-2-89121122 Tel: +31-13-4609292 E-mail: info@hq.ute.com E-mail: info@eu.ute.com Address: 5F, No.
Warranty Policy The items covered under the unitech Limited Warranty are free from defects during normal use. The warranty period is varied from each country. Please consult with your supplier or unitech local office for actual length of warranty period to your purchased product. Warranty becomes void if equipment is modified, improperly installed or used, damaged by accident or neglect, or if any parts are improperly installed or replaced by the user. x © 2016 unitech Electronics Co., Ltd.
Table of Contents Preface...........................................................................................................i About This Manual ........................................................................................ i Regulatory Compliance Statements .............................................................. i Laser Information ......................................................................................... v LED Information .............................................
3.11 MSI/PLESSEY Code Parameters .......................................................29 3.12 Code 2 of 6 Parameters .....................................................................30 3.13 LCD25 Parameters.............................................................................31 3.14 Telepen Parameters ...........................................................................32 3.15 GS1 Databar ......................................................................................33 3.
Chapter 1 - Overview 1.1 Package Please make sure the following contents are in the MS340B gift box. If something is missing or damaged, please contact your unitech representative. The standard package contents: MS340B Scanner Quick Start Guide Regulatory Compliance Statements Cable Cradle Adapter Note: To scan a barcode, make sure the aiming beam crosses every bar and space of the barcode. 1 © 2016 unitech Electronics Co., Ltd. All rights reserved.
1.2 Scanner & Cradle Detail Scanner LED indicator Scan Window Trigger Cradle Cradle LED indicator Cable connector 2 © 2016 unitech Electronics Co., Ltd. All rights reserved. unitech is a registered trademark of unitech Electronics Co.
1.3 Specifications Optical & Performance Sensor Linear Imager Visual Indicators Beep and LED (Good read Green) System Interface USB Light Source 635 nm Visible Red LED Max. Resolution 4mil (0.
Mechanical Dimensions 72 x 70 x 164 mm (length x width x height) Weight 174g (Scanner only) Switch life 1,000,000 times Electrical Input Voltage 5VDC Operating Power <200mA Standby Power < 60mA Battery Li-ion 3.7V/2600 mAh Charging time Approx. 5 hours Reads per charge 50,000 times Environmental Light Levels Max 100,000 Lux Mechanical Shock 1.
Readable Symbologies 5 © 2016 unitech Electronics Co., Ltd. All rights reserved. unitech is a registered trademark of unitech Electronics Co.
1.4 Getting Started Please scan below barcode to set default for BT parameter. For configuration, please refer to 2.1 Flow Chart. BT Parameter Set Default 1.4.1 Scanner Mode There are three different scanner modes. Please follow the instructions below. A. Setup SPP Master Mode* (Default option) SPP Master Mode* Please follow the below steps to setup the communication between the scanner and cradle. 1) The scanner must scan “SPP Master Mode” barcode to set the scanner in master mode.
C. Setup HID Slave Mode HID Slave Mode Please follow the steps to setup the communication between the scanner and Bluetooth HID profile application device. 1) 2) 3) The scanner must scan “HID Slave Mode” barcode to set the scanner in HID slave mode. When control the BT device to search the scanner, enter pin code (default 00:00:00) to setup pairing. You can scan number barcode on Appendix D, “Numeric Bar Codes 2 ” number 0~9, to setup.
1.4.2 Installing battery To install the scanner battery, please follow the instructions below. 1. Use screwdriver to loosen the screw on the bottom of the scanner and remove the battery cover. 2. Slide and position the battery, make sure the battery contacts are aligned with the contacts in the scanner. + - 3. Replace the battery cover and use the screwdriver to tighten the screw on the bottom of the scanner. 8 © 2016 unitech Electronics Co., Ltd. All rights reserved.
1.4.3 Switching Cable Before removing the cable from the cradle, it is recommended that the power on the host system is off and the power supply has been disconnected from the unit. 1. Find the small "Pin-hole" on the bottom of the cradle. (Please see the photo as below) 2. Use a bended regular paperclip and insert the tip into the hole. 3. You will hear a "click", then gently pull out the strain-relief of the cable. Pin-hole 9 © 2016 unitech Electronics Co., Ltd. All rights reserved.
1.5 Battery Charging The battery is in advance loaded into the compartment of the scanner and may not be fully charged before shipment. When you receive the package and use the MS340B for the first time, you will need to fully charge the battery. It takes approximately 5 hours to fully charge the battery. To chage the scanner with a cradle, please follow the instructions below. 1. Plug the adapter cable into the power socket on the bottom of cradle. 2. Plug the AC adapter cord into an electrical outlet.
1.
■ Cradle LED Status Action/Status Good read and transmitted LED for Barcode reading & Communication Green light blinks once BT disconnect (continuously) Blue light blinks twice BT connected Solid blue light 12 © 2016 unitech Electronics Co., Ltd. All rights reserved. unitech is a registered trademark of unitech Electronics Co.
Chapter 2 – Configuration-General 2.1 Flow Chart *Please scan the following barcodes for configuration Start Configuration End Configuration Abort Configuration Save Parameters 13 © 2016 unitech Electronics Co., Ltd. All rights reserved. unitech is a registered trademark of unitech Electronics Co.
2.2 Loop of Programming The philosophy of programming parameters has been shown on the flow chart of 2.1. Basically user should : 1. 2. 3. 4. 5. Scan Start of Configuration. Scan all necessary labels for parameters that meet applications. Scan End of Configuration to end the programming. To permanently save the settings you programmed, just scan label for Save Parameters. To go back to the Default Settings, just scan label for Set All Defaults. ( Please refer to 2.4 – Main Page of Configuration) 2.
2.4 Main Page of Configuration Save Parameters Recall Stored Parameters Set All Defaults** Start Configuration End Configuration Abort Configuration Version Information** ** : Quick Setting Label Save Parameters -The parameter settings will be saved permanently. Recall Stored Parameters - Replace the current parameters by the parameters you saved last time. Set AII Defaults - Set all the parameters to the factory default settings. Abort Configuration - Terminate current programming status.
Chapter 3 –Bar Codes & Others 3.
Telepen ON Reserved5 ON Telepen OFF * Reserved5 OFF * GS1 DataBar GS1 DataBar Omnidirectional Omnidirectional ON OFF * GS1 DataBar Limited GS1 DataBar Limited OFF * ON Reserved6 ON Reserved6 OFF * GS1 DataBar GS1 DataBar Expanded OFF * Expanded ON Select All Bar Codes 17 © 2016 unitech Electronics Co., Ltd. All rights reserved. unitech is a registered trademark of unitech Electronics Co.
3.2 UPC/EAN/JAN Parameters A. Reading Type UPCA=EAN13 ON ISBN-10 Enable B. Supplemental Set Up UPCA=EAN13 OFF * ISBN-13 Enable * ISSN Enable ISSN Disable * Decode with Supplement Auto discriminate Not Transmit * Transmit 2 Code Transmit 5 Code Transmit 2&5 Code Supplement * Expand UPC-E Enable Expand UPC-E Disable * EAN8=EAN13 EAN8=EAN13 Disable * Enable GTIN Format GTIN Format Enable Disable * 18 © 2016 unitech Electronics Co., Ltd. All rights reserved.
C. Check Digit Transmission UPC-A Check Digit Transmission ON * UPC-A Check Digit Transmission OFF UPC-E Check Digit Transmission ON * UPC-E Check Digit Transmission OFF EAN-8 Check DigitTransmission ON * EAN-8 Check DigitTransmission OFF EAN-13 Check Digit Transmission ON * EAN-13 Check Digit Transmission OFF ISSN Check Digit Transmission ON * ISSN Check Digit Transmission OFF 19 © 2016 unitech Electronics Co., Ltd. All rights reserved. unitech is a registered trademark of unitech Electronics Co.
3.3 Code 39 Parameters A. Type of Code B. Check Digit Transmission Italian Pharmacy/ Code 32 OFF * Do Not Calculate Check Digit * Disable * Italian Pharmacy/ Code 32 ON Calculate Check Digit & Transmit Enable Standard * C. Output Start/Stop D. Decode Asterisk Character Disable * Enable Calculate Check Digit & Not Transmit Full ASCII E. Set Up Code Length To set the fixed length: 1. Scan the “Begin“ label of the desired set. 2.
3.4 Code 128 Parameters A. Reading Type B. Check Digit Transmission C. Append FNC2 UCC/EAN-128 Disable * UCC/EAN-128 Enable Calculate Check Digit& Not Transmit * OFF* Enable ‘]C1‘Code Format * Disable ‘]C1‘Code Format Calculate Check Digit & Transmit ON Enable Code128 Group Separators(GS) * Disable Code128 Group Separators(GS) Do Not Calculate Check Digit D. Set Up Code Length To set the fixed length: 1. Scan the “Begin“ label of the desired set. 2.
3.5 Interleave 25 Parameters A. Check Digit Transmission B. Set Up Number of Character Do Not Calculate Check Digit * Calculate Check Digit & Transmit C. Brazilian Banking Code Even * Disable * Odd Enable Calculate Check Digit & Not Transmit D. Set Up Code Length To set the fixed length: 1. Scan the “Begin“ label of the desired set. 2. Go to Numeric Bar Codes in Appendix A, scan label(s) that represents the length to be read. 3. Scan the “Complete“ label of the desired set.
3.6 Industrial 25 Parameters A. Reading Type B. Check Digit Transmission IATA25 Disable * Do Not Calculate Check Digit * IATA25 Enable Calculate Check Digit & Transmit Calculate Check Digit & Not Transmit C. Set Up Code Length To set the fixed length: 1. Scan the “Begin“ label of the desired set. 2. Go to Numeric Bar Codes in Appendix A, scan label(s) that represents the length to be read. 3. Scan the “Complete“ label of the desired set. Repeat the steps 1 - 3 to set additional lengths.
3.7 Matrix 25 Parameters A. Check Digit Transmission Do Not Calculate Check Digit * Calculate Check Digit & Transmit Calculate Check Digit & Not Transmit B. Set Up Code Length To set the fixed length: 1. Scan the “Begin“ label of the desired set. 2. Go to Numeric Bar Codes in Appendix A, scan label(s) that represents the length to be read. 3. Scan the “Complete“ label of the desired set. Repeat the steps 1 - 3 to set additional lengths. Variable * Fix Length (2 Sets Available) 1. 1ST Set Begin 1.
3.8 CODABAR/NW7 Parameters A. Set Up Start/ Stop Characters Upon Transmission B. Transmission Type of Start/Stop OFF * A/B/C/D Start * ON A/B/C/D Stop * A Start A Stop B Start B Stop C Start C Stop D Start D Stop 25 © 2016 unitech Electronics Co., Ltd. All rights reserved. unitech is a registered trademark of unitech Electronics Co.
C. Set Up Code Length To set the fixed length: 1. Scan the “Begin“ label of the desired set. 2. Go to Numeric Bar Codes in Appendix A, scan label(s) that represents the length to be read. 3. Scan the “Complete“ label of the desired set. Repeat the steps 1 - 3 to set additional lengths. Variable * Fix Length (2 Sets Available) 1. 1st Set Begin 1. 2nd Set Begin 2. Numeric Bar Codes (Appendix A) 2. Numeric Bar Codes (Appendix A) 3. 1st Set Complete 3. 2nd Complete Minimum Length 1. Begin 2.
3.9 Code 93 Parameters A. Check Digit Transmission Calculate Check 2 Digits & Not Transmit * Do Not Calculate Check Digit B. Set Up Code Length To set the fixed length: 1. Scan the “Begin“ label of the desired set. 2. Go to Numeric Bar Codes in Appendix A, scan label(s) that represents the length to be read. 3. Scan the “Complete“ label of the desired set. Repeat the steps 1 - 3 to set additional lengths. Variable* Fix Length (2 Sets Available) 1. 1st Set Begin 1. 2nd Set Begin 2.
3.10 Code 11 Parameters A. Check Digit Transmission Do Not Calculate Check Digit * Calculate Check 1 Digit & Transmit Calculate Check 1 Digit & Not Transmit Calculate Check 2 Digit & Transmit Calculate Check 2 Digit & Not Transmit B. Set Up Code Length To set the fixed length: 1. Scan the “Begin“ label of the desired set. 2. Go to Numeric Bar Codes in Appendix A, scan label(s) that represents the length to be read. 3. Scan the “Complete“ label of the desired set.
3.11 MSI/PLESSEY Code Parameters A. Check Digit Transmission Calculate Check Digit & Not Transmit * Do Not Calculate Check Digit Calculate Check Digit & Transmit B. Set Up Code Length To set the fixed length: 1. Scan the “Begin“ label of the desired set. 2. Go to Numeric Bar Codes in Appendix A, scan label(s) that represents the length to be read. 3. Scan the “Complete“ label of the desired set. Repeat the steps 1 - 3 to set additional lengths. Variable * Fix Length (2 Sets Available) 1.
3.12 Code 2 of 6 Parameters A. Check Digit Transmission Do Not Calculate Check Digit * Calculate Check Digit & Transmit Calculate Check Digit & Not Transmit B. Set Up Code Length To set the fixed length: 1. Scan the “Begin“ label of the desired set. 2. Go to Numeric Bar Codes in Appendix A, scan label(s) that represents the length to be read. 3. Scan the “Complete“ label of the desired set. Repeat the steps 1 - 3 to set additional lengths. Variable * Fix Length (2 Sets Available) 1.1st Set Begin 1.
3.13 LCD25 Parameters A. Check Digit Transmission Do Not Calculate Check Digit * Calculate Check Digit & Transmit Calculate Check Digit & Not Transmit B. Set Up Code Length To set the fixed length: 1. Scan the “Begin“ label of the desired set. 2. Go to Numeric Bar Codes in Appendix A, scan label(s) that represents the length to be read. 3. Scan the “Complete“ label of the desired set. Repeat the steps 1 - 3 to set additional lengths. Variable * Fix Length (2 Sets Available) 1. 1st Set Begin 1.
3.14 Telepen Parameters A. Type of Code B. Check Digit Transmission Full ASCII Mode * Calculate Check Digit & Not Transmit* Compressed Numeric Mode Do Not Calculate Check Digit Calculate Check Digit & Transmit C. Set Up Code Length To set the fixed length: 1. Scan the “Begin“ label of the desired set. 2. Go to Numeric Bar Codes in Appendix A, scan label(s) that represents the length to be read. 3. Scan the “Complete“ label of the desired set. Repeat the steps 1 - 3 to set additional lengths.
3.15 GS1 Databar A. GS1 DataBar Omnidirectional B. GS1 DataBar Limited Parameters Transmit Check Digit * Don’t Transmit Check Digit Transmit Check Digit * Transmit Application ID * Don’t Transmit Application ID Transmit Application ID* Don’t Transmit Symbology ID * Transmit Symbology ID Don’t Transmit Symbology ID * Don’t Transmit Check Digit Don’t Transmit Application ID Transmit Symbology ID C.
3.16 Bar Code ID OFF * ON Default With this function ON, a leading character will be added to the output string while scanning code, user may refer to the following table to know what kind of bar code is being scanned. Please refer to the table below for matching code ID of codes read in.
User Define Code ID To set the code ID: 1. Scan the symbologies label. 2. Go to the ASCII Tables in Appendix B, scan label that represents the desired code ID. Note : User define code ID will override default value. Program will not check the conflict. It is possible to have more than two symbologies which have same code ID.
LCD25 GS1 DataBar Omnidirectional ON GS1 DataBar Limited ON Reserved5 GS1 DataBar Expanded ON Reserved6 36 © 2016 unitech Electronics Co., Ltd. All rights reserved. unitech is a registered trademark of unitech Electronics Co.
Chapter 4 – Command Setting 4.1 Interface & Reading Mode Selection 4.1.1 Cradle Interface Selection USB Mode * RS232 Mode Virtual COM 4.1.2 Reading Mode Selection Trigger ON/OFF * Good Read OFF Continuous/Trigger OFF Testing Continuous/Auto Power On Flash/Auto Power On Flash Presentation 37 © 2016 unitech Electronics Co., Ltd. All rights reserved. unitech is a registered trademark of unitech Electronics Co.
4.1.3 BT Auto Connection Disable Enable* 4.1.4 iOS Hotkey Function When enabling iOS Hotkey, you may simply double-click the trigger to toggle the iPhone/iPad Touch Keyboard. Note: This function is only available for iPhone/iPad. Enable Disable* 38 © 2016 unitech Electronics Co., Ltd. All rights reserved. unitech is a registered trademark of unitech Electronics Co.
4.2 Communication Parameters 4.2.1 RS232 Communication Parameters A. Set Up BAUD Rate B. Set Up Data Bits C. Set Up Stop Bits 9600 * 8 Data Bits * 1 Bit* 1200 7 Data Bits 2 Bits 2400 4800 19200 38400 39 © 2016 unitech Electronics Co., Ltd. All rights reserved. unitech is a registered trademark of unitech Electronics Co.
D. Set Up Parity E. Handshaking None * RTS/CTS Disable * Even ACK/NAK Disable * Odd XON/XOFF Disable * RTS/CTS Enable ACK/NAK Enable XON/XOFF Enable Mark Space 40 © 2016 unitech Electronics Co., Ltd. All rights reserved. unitech is a registered trademark of unitech Electronics Co.
4.2.2 Output Characters Parameters A. Select Terminator B. Time-out Between Characters CR* 0 ms * None 5 ms CR +LF 10 ms LF 25 ms Space 50 ms HT(TAB) 100 ms STX-ETX 200 ms 300 ms 41 © 2016 unitech Electronics Co., Ltd. All rights reserved. unitech is a registered trademark of unitech Electronics Co.
4.3 Language Selection US English * Hungarian UK English Janpanese Italian Belgium Spanish Portuguese French Denmark German Netherlands Swedish Turkey Switzerland Reserved 2 42 © 2016 unitech Electronics Co., Ltd. All rights reserved. unitech is a registered trademark of unitech Electronics Co.
4.4 Reading Level The Polarity can be sent as standard with black bars high, or reversed with white bars high. Black Bars High * White Bars High 43 © 2016 unitech Electronics Co., Ltd. All rights reserved. unitech is a registered trademark of unitech Electronics Co.
4.5 Accuracy This setting is to provide the assurance of barcode consistency and to prevent the misread outcome before the data is sent to the host.Scan the barcode below to choose how many times you would like to verify the data. Note: It will cause the scanning process to slow down by choosing more than 1 time to verify the data. 1 Time * 2 Times 3 Times 4 Times 4.6 Buzzer Beep Tone High * Medium Low Off 44 © 2016 unitech Electronics Co., Ltd. All rights reserved.
4.7 Sensitivity of Continuous Reading Mode A. Quick Setting Fast * Slow B. Same Code Delay Reading Interval Following code sequences represent the length of time before a barcode can be rescanned at continuous and flash reading mode. The value can be defined from 1-50 and they represent 100ms to 5 seconds in100ms interval. Default value is 3 (0.3 seconds). To setup same code delay reading interval: 1. Scan the "Begin" label 2.
4.8 Reverse Output Characters Disable * Enable 4.9 Setup Deletion To setup the deletion of output characters: 1. Scan the label of the desired set below. 2. Scan the label of the desired symbology. 3. Go to the Numeric Bar Codes in Appendix A, scan label(s) that represents the desired position to be deleted. 4. Scan the “Complete” label of “Character Position to be Deleted”. 5. Go to the Numeric Bar Codes in Appendix A, scan label(s) that represents the number of characters to be deleted. 6.
B. Symbologies Selection Industrial 25 UPC-A UPC-E Matrix 25 EAN-13/JAN-13/ISBN-13 CODE 93 EAN-8/JAN-8 CODE 11 CODE 39 China Postage CODE 128 MSI/PLESSEY CODABAR/NW7 Code 2 of 6 Interleave 25 Telepen LCD25 GS1 DataBar Omnidirectional GS1 DataBar Limited GS1 DataBar Expanded None All Codes 47 © 2016 unitech Electronics Co., Ltd. All rights reserved. unitech is a registered trademark of unitech Electronics Co.
C. Character Position to be Deleted 2. Complete 1. Numeric Bar Codes (Appendix A) D. Number of Characters to be Deleted 2. Complete 1. Numeric Bar Codes (Appendix A) 48 © 2016 unitech Electronics Co., Ltd. All rights reserved. unitech is a registered trademark of unitech Electronics Co.
4.10 Setup Insertion To setup the insertion of output characters : 1. Scan the label of the desired set. 2. Scan the label of the desired symbology. 3. Go to the Numeric Bar Codes in Appendix A, scan label(s) that represents the desired position to be inserted. 4. Scan the “Complete” label of “Character Position to be Inserted”. 5. Go to the ASCII Tables in Appendix B or Function Key Tables in Appendix C, scan label(s) that represents the desired characters to be inserted.
B. Symbologies Selection Industrial 25 UPC-A UPC-E Matrix 25 EAN-13/JAN-13/ISBN-13 CODE 93 EAN-8/JAN-8 CODE 11 CODE 39 China Postage CODE 128 MSI/PLESSEY CODABAR/NW7 Code 2 of 6 Interleave 25 Telepen LCD25 GS1 DataBar Omnidirectional GS1 DataBar Limited GS1 DataBar Expanded None All Codes 50 © 2016 unitech Electronics Co., Ltd. All rights reserved. unitech is a registered trademark of unitech Electronics Co.
C. Character Position to be Inserted 2. Complete 1. Numeric Bar Codes (Appendix A) D. Characters to be Inserted 2. Complete 1. ASCII Table (Appendix B) 51 © 2016 unitech Electronics Co., Ltd. All rights reserved. unitech is a registered trademark of unitech Electronics Co.
4.11 PAN Configuration 4.11.1 Auto Mode Auto Mode Enable * Auto Mode Disable When “Auto Mode” function is enabled, and the scanner is working at out of transmission range, the scanned data will be stored to out-of-range memory. Memory size is approximately 25,000 sets of EAN13 barcode type. The all stored data will be transmitted to device when the link is reconnected, and the all data stored in out-of-range memory will be cleared. 4.11.2 Sleep Mode Sleep Mode OFF* Sleep Mode 1 min.
4.11.3 Batch Mode Batch Mode OFF* Batch Mode ON Delete Last Data ** Batch Data Read ** Batch Data Clear ** ** : Quick Setting Label The function can be executed directly by scanning barcode instead of doing the general programming process. 53 © 2016 unitech Electronics Co., Ltd. All rights reserved. unitech is a registered trademark of unitech Electronics Co.
4.11.4 Firmware Version Scanner Firmware Version** Cradle Firmware Version** Scanner MAC Address** Cradle MAC Address** ** : Quick Setting Label Display the firmware version of the scanner, please scan above barcode. 54 © 2016 unitech Electronics Co., Ltd. All rights reserved. unitech is a registered trademark of unitech Electronics Co.
Appendix A –Numeric Bar Codes 55 © 2016 unitech Electronics Co., Ltd. All rights reserved. unitech is a registered trademark of unitech Electronics Co.
Appendix B –ASCII Table 56 © 2016 unitech Electronics Co., Ltd. All rights reserved. unitech is a registered trademark of unitech Electronics Co.
57 © 2016 unitech Electronics Co., Ltd. All rights reserved. unitech is a registered trademark of unitech Electronics Co.
58 © 2016 unitech Electronics Co., Ltd. All rights reserved. unitech is a registered trademark of unitech Electronics Co.
59 © 2016 unitech Electronics Co., Ltd. All rights reserved. unitech is a registered trademark of unitech Electronics Co.
Appendix C –Function Key Table 60 © 2016 unitech Electronics Co., Ltd. All rights reserved. unitech is a registered trademark of unitech Electronics Co.
Appendix D–Numeric Bar Codes2 61 © 2016 unitech Electronics Co., Ltd. All rights reserved. unitech is a registered trademark of unitech Electronics Co.