XID-300 User Manual Version Eng-0.
2 Safezone XID-300 < Contents > 1. Before Use ................................................................................................................................................ 3 1.1. Safety Precautions....................................................................................................................................................... 3 1.2. Terminal Description ..................................................................................................................
3 Safezone XID-300 1. Before Use 1.1. Safety Precautions z Warning Do not handle the unit with wet hands and do not allow liquid to flow into, or on, it. -> It may cause an Do not place a fire source near the unit. -> It may cause a fire. electric shock or damage. Do not disassemble, repair, Keep out of children’s or modify the unit. reach. -> It may cause an electric -> shock, fire or damage. accident or damage.
4 Safezone XID-300 Avoid using insecticides Avoid getting the fingerprint input area dirty. ->It may prevent the unit from recognising the fingerprint. or flammable sprays near the unit. -> It may result in the deformation or change the colour of the unit. Avoid installing the unit Avoid impact or using in a place where sharp objects on the unit. temperature changes -> The unit may get severely. damaged and broken. It may cause the unit to malfunction.
5 Safezone XID-300 1.2. Terminal Description State Display LED LCD Card Input Area Touch Key Normally, the figures are invisible as the LED is off. LED turns on and the figures illuminate when the user lightly 1.3.
6 Safezone XID-300 1.3.1 Icons Shown During Operation Door Status : Door status is unknown. : Door is closed. : Door is open. Connection Server of : LAN cable is connected, but not yet to the server. : Connected with the server. 1.3.2 Message Shown During Operation When authentication is successful. When authentication has failed. - As any unregistered card is input. When authentication has failed. - As card is registered at BL.
7 Safezone XID-300 When authentication has failed. - As card is expired. When the lid of the terminal is opened 1.3.3 LED Signal Shown During Operation Green When authentication has failed, when the lid of the terminal is opened Red When authentication is successful. 1.3.4 Keys Used During Operation [0] ~[9] - Keys used for numeric input. [F1] - When put IP, it is used as dot (.) [F4(Í)] - When you put numbers, it is used as Delete.
8 Safezone XID-300 When authentication has failed. This card is not registered. Please try again. When terminal is Initialized Terminal is initializing 1.3.6 Buzzer Sounds Used During Operation Beep When the key is pressed or card is read Be peep when the lid of the terminal is opened 1.4. How to unplugged terminal power supply safely When you put [ENT] for 3seconds, LED of keypad is off and then on with Beep sound. After taking off your finger, the following left screen appears.
9 Safezone XID-300 2. Product Introduction 2.1. Features • Slim and polished design - Easy to install as it is designed as a standalone type; Slim and elegant design using Colour LCD and Touch Keys • Change the LCD background image and voice using USB. - Provides a variety of information messages via the colour LCD screen and voices. You can download background images and voice messages suing USB.
10 Safezone XID-300 2.2.
11 Safezone XID-300 2.3. Specification Item Specification CPU 32Bit RISC CPU(400MHz) LCD 2.8” TFT Color (320*2400 Touch Key 15Key (0~9, F1~F4,Enter) Memory 32M SDRAM Remarks 16M NOR FLASH 128M NAND FLASH Temperature/ -20 ~ 50 / Humidity Lower than 90% RH AC / DC Adapter INPUT : Universal AC100 ~ 250V Output OUTPUT : DC 12V Communication Port RS485 Card Reader 13.56Mhz Smart Card Size 88.0mm * 175.0mm * 43.
12 Safezone XID-300 3. Environment Settings 3.1. Enter the Menu. When you put [ENT] for 3seconds, LED of keypad is off and then on with Beep sound. After taking off your finger, the following screen appears. The initial password is 2345. 3.1.1 When you forget password You make your terminal to be disconnect. Door state is changed to gray . (You can’t change password while using terminal.) Make /xid30/pw folder in USB and connect USB and terminal.
13 Safezone XID-300 3.2. Menu Configuration 1. Network 1. Terminal IP Terminal IP Gateway Subnet mask 2. Server IP Server IP Server PORT 2. System 1. Language Korean English 2. Volume Control 1. Voice Volume 2. Beeper Volume 3. Initialize 1. Setting Initialization 2. Data Initialization 3. Terminal Initialization 4. Door Control 1. Open duration 2. Door setting 5. Password change 6. Background change 3. Application - Access, TNA, Meal Attendance, fire 4.
14 Safezone XID-300 3.2.1 Network - If pressing [1] at Admin main menu, the following screen appears 3.2.1.1 Terminal IP and Server IP setting - If you want to change it, press [1] and select <1. Terminal IP>. When you set IP, [F1] is for “.”(dot) The user can exit to the parent menu using the [ENT~] key to apply the changed values. Use the [F4 (←)] key to cancel input during setting. - After pressing [2] and select <2.Sever IP>, you can change it same as <1. Terminal IP>.
15 Safezone XID-300 3.3.1 System Setting - Put [2] at a main menu, and the following screen appears 3.3.1.1 Language - Selete <1. Language> as putting [1]. You can change what you want as putting [1]or [2]. The user can exit to the parent menu using the [ENT~] key to apply the changed values. Use the [F4 (←)] key to cancel input during setting. 3.3.1.2 Volume - You press [1] and select <2. Volume>. You can change what you want pressing [0] ~ [5].
16 Safezone XID-300 3.3.1.3 Initialization - If you want to initialize what you set, press [1]. If you want to delete data, press [2]. If you want to initialize terminal, press [3] - When you press key you want, the following screens appear. If you want to initialize, press [ENT]. If you want to cancel it, press [F4Å]. If you select Initialization, terminal is reset after initializing. - Setting initialization initializes all data of terminal without MAC address.
17 Safezone XID-300 - Terminal initialization initializes the whole of terminal. 3.3.1.4 Door Control - Designates the time the door is opened and closed again when authentication is successful. Minimum value is 1 sec and maximum value is 9sec. - <1. Door open> is for that door opens and closes one time. <2. Door open by force> is for that door is always opened. <3. Door open clear> is for that <2> is made to close. - The user can exit to the parent menu using the [ENT~] key to apply the changed values.
18 Safezone XID-300 3.3.1.6 Background image - It’s for changing background image. You can select it you want using [1],[2]. The user can exit to the parent menu using the [ENT~] key to apply the changed values. Use the [F4 (←)] key to cancel input during setting. 3.4.1 Application - If pressing [3] at admin main menu, the following screen appears. - You can select application type pressing number you want. The user can exit to the parent menu using the [ENT~] key to apply the changed values.
Safezone XID-300 Copyright ⓒ 2011 LG CNS
19 Safezone XID-300 3.5.1 Terminal Info - If you press [4] at Admin main menu, the following screen appears. - You can check terminal version and Door open state from Terminal Info. 3.6.1 Option - You can see the following screen appears if pressing [5]. - Lamp (Yes or No) : If setting that Lamp is yes and Look Controller is connected with it, when authentication is successful, blue of lamp light is on and When authentication is fail, red of lamp is on.
TDK - EMC Components - Part No: ZCAT1730-0730A Characteristics Page 1 of 1 Close Window EMC Components Clamp Filters (Ferrite Core with Case) Part Number : ZCAT1730-0730A Product Name : Clamp Filters TDK Series Name : ZCAT Series Application : Personal computers, word processors, monitors, hard disk drives, digital telephones, audio devices, electronic musical instruments, video games, copiers and facsimiles. Function : A type means Cable fixed type( hold the cable to secure it with the main body).