UBio-X Pro User Guide Version Eng-1.02 Copyright 2000 By Union Community Co., LTD.
UBio-X Pro User Guide Version Date Description 1.00 2018-12-27 Initial Release 1.01 1.02 1.03 2019-02-07 2019-03-07 2019-03-15 Modification for issues from RQA Change the screen shot for Terminal Info Remove the enrollment auto sensitivity Change the screen shots for Meal Management Firmware Version UNIONCOMMUNITY Co., Ltd.
UBio-X Pro User Guide 3 < Glossary> Admin, Administrator - A user who can enter into the terminal menu mode, he/she can register/modify/delete terminal users and change the operating environment by changing settings. - If there is no administrator for a terminal, anyone can change the settings. In this regard, it is recommended to register at least one administrator.
UBio-X Pro User Guide Contents .................................................................................................... 2 < Glossary> ............................................................................................................... 3 Contents ................................................................................................................... 4 1. Before use .........................................................................................
UBio-X Pro User Guide 5 3.6.4. Auth .............................................................................................................. 50 3.6.5. Date/Time ..................................................................................................... 52 3.6.6. Database ...................................................................................................... 53 3.6.6.1. Delete all the users................................................................................ 53 3.
UBio-X Pro User Guide 6 3.12.5. Disconnect from app and BT module in recognizer ..................................... 76 4. How to use terminal ........................................................................................... 77 4.1. How to change Auth mode .................................................................................. 77 4.2. How to input user ID ............................................................................................ 78 4.3. How to authorize ...........
UBio-X Pro User Guide 1. Before use 1.1. Safety Precautions Warning Handling with wet hands or allowing liquid to flow into it is prohibited. -> It may cause an electric shock or damage. Do not place a fire source near the terminal. -> It may cause a fire. Do not disassemble, repair, or modify the terminal at discretion. -> It may cause an electric shock, fire or damage. Keep out of reach of children. -> It may cause an accident or damage.
UBio-X Pro User Guide 1.2. Specific names of the terminal IR LED Michrophone Illumination sensor Touch LCD Fingerprint sensor Card Sensing Area IR LED Dual Camera SD card input Speaker UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.
UBio-X Pro User Guide 1.3. Windows after operation ① Icon for motion detection ② Icon for illumination status ③ Warning icon for Fire alarm ④ Warning icon for tamper switch ⑤ Icon for door status ⑥ Icon for network status Menu button Time & Date ID input button Function Keys Camera movie display Guide for face recognition 1.3.1.
UBio-X Pro User Guide : Door is closed : Door is opened : Door is opened abnormally : There is not connected LAN cable ⑥ Network Status : Disconnected to the server even LAN cable is connected : Connected to the server (On line) 1.3.2. Message - Basic Window - When authorization is successful - When authorization is failed UNIONCOMMUNITY Co., Ltd.
Failed! 11 UBio-X Pro User Guide - When unregistered user ID is entered Unregistered! - When unregistered card is entered Unregistered Card! - Passback error when using anti-passback function Passback error! - When a user tried the authorization more than twice in one meal time when using as meal management Duplicated! Network Error! - When the server does not respond during the authorization attempt to the server - When the network is disconnected during the authorization attempt to the server UNIO
UBio-X Pro User Guide - Registration without authorization right or authorization attempt when the entrance is not permitted No permission! - When the user is designated in the blacklist Restricted! - When the terminal is set locked Locked ! - When it is not the meal time when set in the meal personnel management No Meals Available UNIONCOMMUNITY Co., Ltd.
UBio-X Pro User Guide - The state waiting for the input of the user ID - The state waiting for the input of password - The state waiting for the input of fingerprint Place finger on sensor UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.
UBio-X Pro User Guide - The state waiting for the input of the card Verify Card Place your card - When the terminal program is being upgraded (In this state, you should not turn off the terminal) Upgrading... Do not power off ! 1.4. Voice sounds in operation Operation type Voice sound Success to authorize You are authorized Fail to authorize Please try again 1.5.
UBio-X Pro User Guide 15 Face authorization method You can select two modes as the face authorization method. - Normal mode: When the user gets close within 1.5m, the tilting function of the camera is operated by recognizing the face of user. When the user is within 50~70cm, the face authorization is fulfilled.
UBio-X Pro User Guide 16 Check if your fingerprint is unclear or damaged. It is tricky to recognize fingerprints on dry, wet, unclear, or injured fingers. Use another finger in this case Be aware of certain fingerprint conditions Depending on the user’s fingerprint condition, some fingerprints may not be used or may cause an inconvenience. If the fingerprint is damaged or very unclear, then it cannot be recognized. Please use a password instead in this case.
UBio-X Pro User Guide 2. Product introduction 2.1. Product characteristics Multi-Modal product with which the user can use both face and fingerprint authorization functions together. . Superior ability for the face recognition under external light condition (30,000 lux) FHD(2M) Display resolution is adapted. The face recognition is possible even in the dark place with the illumination sensor and dual camera (color & IR) and saving the discriminable log images. RF(125kHz) and Smart Card(13.
UBio-X Pro User Guide Fingerprint password or Fingerprint, password registration Password authorization when fingerprint authorization was failed Fingerprint& Password Fingerprint, password registration Password authorization after fingerprint authorization Card or face Card, face registration Card or face authorization Card & face Card, face registration Face authorization after the card authorization Face or password Face, password registration Face authorization or password authorization wh
UBio-X Pro User Guide 2.2. Product components 2.2.1. Standalone use (Access) DC15V Adapter Electric lock (Lock+, Lock-, Monitor) 2.2.2. Connected with Server (Access, Attendance, Meal management) TCP/IP TCP/IP TCP/IP Fingerprint authorization server (static IP) UDB server database (MDB or MSSQL) Internet / WAN / LAN TCP/IP TCP/IP TCP/IP UNIONCOMMUNITY Co., Ltd.
UBio-X Pro User Guide 2.3. Product specification Types SPEC CPU 1GHz Quad Core CPU LCD 5.0 inch Touch LCD(480*800) MEMORY REMARK 16G Bytes Flash 2GBytes RAM External SD Card support Backup data / Upgrade firmware Camera Dual Camera (Color & IR) Auth speed 1:1 < 0.2 Sec Auth speed 1:N(1,000) < 0.
UBio-X Pro User Guide 3. Environment setting 3.1. Checks before setting the environment 3.1.1. Entering the menu If you click the [ follows. ]icon at the basic window, you can enter the main menu window as You can enter the subdivision menu by clicking each button. 3.1.2. Administrator authorization If the administrator is registered, the following administrator authorization window appears first.
UBio-X Pro User Guide 3.1.3. How to enter the menu without administrator authorization It is how to enter the menu when the fingerprint or face authorization is impossible because the administrator card registered in the terminal was lost or there is no administrator. ① Open the cover by removing the bracket at the backside of the terminal ② With the opened cover, connect the 5pin connector number 1 with 3, and 2 with 4 at the bottom of the backside of the terminal.
UBio-X Pro User Guide 23 ▶ If there is no changed value, the window is moved to the previous menu. ▶ If there is no signal for 30 seconds while changing the set value in the menu, the window is moved to the previous menu. UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.
UBio-X Pro User Guide 3.2. Menu composition 1.User 1. 2. 3. 4. 5. 2.Network Terminal IP address Static IP / DHCP ▶IP address ▶Subnet Mask ▶Gateway DNS ▶DNS server 1 ▶DNS server 2 Server IP address ▶Server IP ▶Port Terminal ID ▶Terminal ID 1. Application ▶Access / TnA / Meal 1. Select Access or TnA ▶Schedule F1 (Attend) time F2 (Leave) time F3 (Out) time F4 (In) time Access time ▶Blocking Time 2.
UBio-X Pro User Guide □ Password □ Name Number of Fingers [1~10] 5. Terminal 2. Finger ▶1:N Level [3~9] ▶1:1 Level [1~9] ▶Fake Finger Detection ▶FP template format □ Check similar FP □ Multi FP □ Enable 1:N 3. Face ▶Matching Level [1~4] ▶Face Recognition ▶Enrollment Sensitivity [1~10] ▶Authentication trial limit [1~10] 4. Auth ▶Auth Type □ FP Template Card □ FACE 1:1 Only 5. Date/Time ▶Time synchronization ▶Display Format ▶Set Date ▶Set Time 6. Database 1. 2. 3. 4. 5. 1.
UBio-X Pro User Guide ▶Lock 1 duration (ms) ▶Lock 2 duration (ms) 6. Display 5. External Device ▶RS232 ▶RS485 ▶Wiegand Site Code Wiegand Output Wiegand Input 1. Theme ▶Background 2. Camera ▶Display Option ▶Save Option □ Save success log □ Save failed log 3. Language ▶Language 4. Option ▶Power saving mode ▶Display Option ▶Touch Calibration 5. Message display ▶Message Display time Time (ms) 7. Terminal Info 8. SD Card 1. System ▶System Info ▶Disk ▶Ram 2.
UBio-X Pro User Guide 2. Import 1. User Data 2. System Option 3. Others 1. Theme 2. F/W Upgrade 3.3. User Management When you select the [User] at the main menu, the following window appears. The number of all the users is shown at the top of screen including administrator. Click [Add] button to add the new user, [Modify] button to modify the user, [Delete] button to delete the specific user, [Delete All] button to delete all the users, and [View] button to inquire the registered user list.. 3.3.
UBio-X Pro User Guide Input the user ID to be registered and click [OK] button. In this case, the ID which can be registered is shown on the screen automatically, so you can register conveniently. If you want to change ID, delete the previous value by clicking [ new value. ] button and input the Click [Back] button to cancel and go back. . If you enter ID which is already registered, the failure message appears, and if the ID is not registered, the following screen appears. .
UBio-X Pro User Guide ※ Only user who is registered as administrator can change the operating method of the terminal and can register/modify/delete the information of all the saved users, so be careful to register the administrator 3.3.1.1. Photo registration Register by clicking [ ] button at the [Add User] screen Click the [Save] button to register with the present camera image. Click [Cancel] or [BACK] button to cancel the registration and return. 3.3.1.2.
UBio-X Pro User Guide 3.3.1.3. Fingerprint registration ① Register by clicking [Fingerprint] button at the [Add user] screen. Click [ ] button to cancel the registration and return. Choose the finger to be registered when the left screen appears. ※ If you register the multiple fingers, the fingers already registered are represented by blue circle ( ). And if the duress fingerprints are represented by violet circle ( ).
UBio-X Pro User Guide ② Enter the fingerprint with referring ‘1.7 Proper fingerprint registration and input methods’. Enter the fingerprint twice according to the screen instruction as follows. When the light is turned on at the fingerprint sensor with the message ‘Register FP’, put your finger on the input screen and wait for 2~3 seconds until the light is turned off. ③ When the message ‘Enter the same fingerprint again’ appears, enter the same fingerprint again.
UBio-X Pro User Guide If it is similar with the fingerprint already registered, the message “Already registered finger!” appears like the left side, and you can start again from the procedure of ② if you click the [Retry] button. You can click [ ] button to cancel and return to the upper menu. ※ You can register 10 fingerprints at most for one ID, and you cannot register more than 10 IDs.
UBio-X Pro User Guide 3.3.1.4. Face registration Register with referring ‘1.6. How to register and authorize the face properly‘. ① Press the [Start] button to register the face. Locate your face to be fitted to the face lines like the left picture, and look directly at the screen according to the guidance of the screen. ② If the face was recognized properly like the left picture, the guide is turned green and the face registration begins.
UBio-X Pro User Guide ③ When the registration is ended, the message [Completed!] is appeared like the left screen, and if you click the [OK] button, the face registration is completed and the screen is moved to the previous screen.
UBio-X Pro User Guide 3.3.1.5. Password registration If you enter the password in 1~8 characters into the password input window and click [OK] button, the input focus is moved to the ‘password confirm’ window at below. Enter the same password again and click [OK] button. Click [ ] button to cancel and return. ※If you enter the different password in the confirm window, the message “Wrong input!” appears as follows 3.3.1.6.
UBio-X Pro User Guide 3.3.1.7. Options for authorization ▶’FP Level’ (basic setting:’0’) It decides the fingerprint authorization level of each user, and the registered users can have different authorization level by modifying this value. If you set ‘0’, the authorization uses the level of fingerprint authorization. For example, if you select the “1” for FP Level, this user will applied with “1” on 1:1 FP Level.
UBio-X Pro User Guide Password, it will be limited 2 authorization methods) ※(ID or Card) & FP Card & FP, (ID or Card) & PW Card & PW, (ID or Card) & Face Card & Face, Card & FP & Face & PW Card & FP & Face will be changed automatically. 3.3.1.9. Save Click the [Save] button to save when all the registration procedure is finished. point, if you click [Cancel] or [BACK] button to return, the user is not saved. At this Next is the LCD messages which can appear at the registration procedure.
UBio-X Pro User Guide In [Register FP], the case you input the different fingerprint at the fingerprint registration. In [Register FP], The case you tried to registered the fingerprint already registered. (But, you can input the same fingerprint with the same user ID). ※ If you want to register the same fingerprint in the different ID, you should uncheck the ‘System Fingerprint recognition preventing the similar fingerprint registration’.
UBio-X Pro User Guide Input the user ID to be deleted and click [OK] button. Click [BACK] button to cancel and return. If you input the unregistered ID, the failure message “Unregistered user” appears, and if you input the registered ID, success message “Deleted” appears But, the deletion in the terminal is not led to the deletion in the server, so if you want to delete completely, you should delete it also in the server.
UBio-X Pro User Guide Input the user ID to be modified and click [OK] button. Click [BACK] button to cancel and return. The failure message appears if you input the unregistered ID, and if you input the registered ID, the information of registered user is represented as follows The icons at the left side means as follows.
UBio-X Pro User Guide If you want to delete all the users, click [YES], and if you want to cancel, click [NO]. ※If you click [YES], the users and admin are deleted, and the restoration is impossible once they are deleted, so be careful. 3.3.5. View If you click the [User]->[View] in the main menu, all the users registered can be searched as follows. The user list appears by the order of ID, and if you slide the screen upward, you can search the additional user list.
UBio-X Pro User Guide ▶If you input the User ID by clicking [ID] button, the user is searched like in the left picture. If you click [BACK] button in this window, you can move to the ‘3.3. User management’ menu. ▶[Name] : If you input the user name by clicking [Name] button, the registered user list including the characters is shown. If you click [BACK] button in this window, you can move to the ‘3.3. User management’ menu.
UBio-X Pro User Guide ▶Basic setting : Same with the window at the left side. Select the method [Static IP] if the static IP is allocated from the connected network, and select [DHCP] if the IP is allocated from the DHCP server in the connected network. . If you selected [Static IP], set the IP address, subnet mask, and gateway. And if you selected [DHCP], you don’t have to set them.
UBio-X Pro User Guide 3.5. Application mode 3.5.1. Application If you select the [Application] in the main menu, the following window appears. In the application mode, you can select the [Access / TnA / Meal] according to the purpose. 3.5.1.1. Access or TnA setting It is the screen appearing when you select the Access. Click [OK] button to apply the changes, and click [BACK] button to cancel and return.
UBio-X Pro User Guide button, and it is convenient for the TnA management because the indication mode is changed to the set authorization mode automatically though another mode was authorized by clicking another function key. The time periods should not be overlapped, but if they are overlapped, the application order is Attend(F1)Leave(F2)Out(F3)In(F4)Access. If the time is set between 23:00~01:00, it means from 23:00 to the 01:00 the following day.
UBio-X Pro User Guide ▶Basic setting : Same with the window at the left side. ▶Fn key It means the [F1]~[F4], Access button used to change the authorization mode such as attendance and leaving, and if you click the Fn key, the authorization mode is changed to the mode.
UBio-X Pro User Guide registered in the terminal. [Server Only] : It only authorizes the user registered in the server. [Terminal/Server] : It authorizes the user registered in the terminal as 1:N identification but it authorizes the user in the server as 1:1 verification. [Server/Terminal] : 서It authorizes the user registered in server as 1:N identification but if the network between server to terminal was disconnected, it authorizes the user registered in terminal as 1:N identification.
UBio-X Pro User Guide level, the preventing function of the fake fingerprint input such as rubber, paper, film, or silicon is strengthened, but the fingerprint also can be hard to enter if the finger is dry too much. ▶FP template format It determines the format of fingerprint template. When some applications using SDK need another format of the fingerprint, the fingerprint template format of the terminal can be changed.
UBio-X Pro User Guide 49 It is the function used when managing the access control of the special area strictly. For example, if the user with ID ‘0001’ has three fingerprints registered, the user should be authorized with all three fingerprints after entering ID. In this case, the order of three fingerprints is not important, but if one of the fingerprints is failed to be authorized, the authorization is failed.
UBio-X Pro User Guide 3.6.3. Face ▶ Basic setting : Same with the window at the left side ▶Matching level It is the level used in face authorization, and it can be set 1~4 levels according to the accordance degree with the registered face. And the authorization is successful when the accordance degree is higher than set authorization level.
UBio-X Pro User Guide ▶Basic setting : Same with the window at the left side ▶Auth Type: Select the authorization method of the terminal. - Card: Though the user is registered with the authorization method requiring the face, fingerprint, or password in addition to the card, the terminal with the checking of the item, the card can authorize by itself. For fingerprint, face or password users, follow the same authentication procedure as per normal to authenticate.
UBio-X Pro User Guide ▶Face 1:1 Only If this option is checked( ), face authentication will be worked for 1:1 verification only. 3.6.5. Date/Time If you select the [System] [Date/Time] in the main menu, the following window appears. ▶Basic setting : Same with the window at the left side ▶Time synchronization It determines the synchronization method between the present time of terminal and server.
UBio-X Pro User Guide 3.6.6. Database If you select the [System] [Database] in the main menu, the following window appears. If you want to delete all the users, click [Delete all users] button. If you want to initialize the settings, click [Delete setting] button. If you want to initialize the authorization record, click [Delete Log] button. If you want to delete image log only, click [Delete image log] button.
UBio-X Pro User Guide impossible once the data is deleted. 3.6.6.2. Delete setting If you select the [System] [Database] [Delete setting] in the main menu, the following screen appears. Click [YES] button to initialize all the set values, and click [NO] or [ ] button to cancel. If there is no signal for 5 seconds in this state, the message box disappears without initialization. If the deletion is successful by clicking [YES], the success message in
UBio-X Pro User Guide If you select the [System] [Database] [Delete image log] in the main menu, the following window appears. If you want to delete all the authorization record in the terminal, click [YES] button, and if you want to cancel, click the [NO] or [ ] button. If there is no signal for five seconds in this state, the message box disappears without deletion. If it is deleted successfully by clicking [YES], the success message in [Fig. 3-5] is displayed.
UBio-X Pro User Guide 3.7. Terminal 3.7.1. Sound If you select the [Terminal] [Sound] in the main menu, the following window appears. ▶ Basic setting: Same with the window at the left side. ▶ Voice volume Scroll from side to side in 0~15 degrees to set the voice volume. If you click the [ ] button at the right side, the voice is played to check the volume. ▶ Beep volume Scroll from side to side in 0~3 degrees to set the beep volume.
UBio-X Pro User Guide ▶ Basic setting : Same with the window at the left side. ▶ Read Card number: If the user put the card on the screen, the card number is displayed on the LCD. you can change the [Card format] to check the card number according to the set value. ▶ Lock terminal: This function enables the administrator to lock or unlock the terminal directly on the terminal, not on the server program. If it is checked ( ), none can access due to the lock until the administrator unlock the setting.
UBio-X Pro User Guide 3.7.3. Input If you select the [Terminal] [Input] in the main menu, the following window appears. ▶ Basic setting : Same with the window at the left side. ▶M0: It is set when connecting the external access point to the DM0 (When using motor lock, set [Door open NO] or [Door open NC].) -None: When nothing is connected. -Door open NO or Door open NC: When the door open monitoring pin was connected.
UBio-X Pro User Guide ▶IO: Set when connecting the external access point to the Exit pin. - None: When nothing is connected - Inside Open NO or Inside Open NC: When the exit button was connected - Fire detection NO or Fire detection NC: When the fire detection sensor is connected. - Panic detection NO or panic detection NC’: When the panic situation detection sensor is connected. - Emergency detection NO or emergency detection NC’: When the emergency situation detection sensor is connected.
UBio-X Pro User Guide ▶ Basic setting : Same with the window at the left side. ▶Lock 1 Option - None: When it is not used - Strike/Auto/OK: When the warning light is connected to indicate the strike type, auto door, or authorization success/failure on Lock1. - Motor lock 1: When the motor lock is connected. - Regular notification: When the siren setting of the terminal option was sent to the terminal, it sends the operating signal about it.
UBio-X Pro User Guide 3.7.5. External Device If you select the [Terminal] [External device] in the main menu, the following window appears. . ▶ Basic setting : Same with the window at the left side ▶RS232: It sets the device connected to RS232 port -None: When there is no device connected to the RS232 port -Ticket Format1/ Ticket Format2: The authorization result is printed when the authorization is successful.
UBio-X Pro User Guide None General case. It does not use Wiegand out port. 26bit Because it sends “Sitecode[1byte] + User ID[2 byte]”, set the user ID less or equal than 4 digits. Send example) In case of SiteCode:045(2Dh), UID:6543(198Fh) 1 00101101 0001 1001 10001111 0 34bit Because it sends “Sitecode[1 byte] + User ID[3 byte]”, set the user ID less or equal than 7 digits. But, if the user ID is 8 digits, ignore sitecode and send only the “User ID[4byte]”.
UBio-X Pro User Guide 3.8. Display 3.8.1. Theme If you select [Display] [Theme] in the main menu, the following window appears. ▶ Basic setting : Same with the window at the left side. ▶Background It sets the background of the basic window. You can inquire the next image by clicking [ ] button. Click [OK] button to apply the set value, and click [BACK] button to cancel and return. you want to set another items, click the menu you want to change at the left side. 3.8.2.
UBio-X Pro User Guide ▶ Basic setting : Same with the window at the left side. ▶ Display Option Choose the image displayed in the message window of authorization success - None - Registered user’s picture. - AuthType: Image stands for each AuthType ▶ Save success log If it is checked ( as image log successful. ), the camera image is captured when the authorization was ▶ Save failed log When it is checked ( ), the camera image is captured as image log when the authorization was failed.
UBio-X Pro User Guide 3.8.4. Option If you select [Display] [Option] in the main menu, the following window appears. ▶ Basic setting : Same with the window at the left side. ▶Power saving mode (5sec ~ 10min) If there is no input for set duration, the LCD screen is turned off automatically. But, if you set ‘None’ the LCD is always turned on. ▶Display Option It sets what will be shown at the LCD screen when the authorization is successful.
UBio-X Pro User Guide ▶ Basic setting : Same with the window at the left side. ▶Message Display (ms) It sets the time for which the authorization result window to be displayed. 0~5000 is available for the value, and the authorization result window appeared and disappear for the duration. Because it is set in millisecond, if you want to set 2 seconds, you should set 2000. Click [OK] button to apply the set value, and click [BACK] button to cancel and return. 3.9. Terminal Info 3.9.1.
UBio-X Pro User Guide Click [BACK] button to finish the inquiry and move to the upper menu. Click the menu on the left side to inquire additional item. 3.9.2. Terminal If you click the [Terminal info] [Terminal] in the main menu, the following window appears. ▶ Terminal info It represents the option setting value of the terminal. Click [Close] or [BACK] button to finish the inquiry and move to the upper menu. 3.9.3.
UBio-X Pro User Guide ▶ Network info It shows the network setting value of the terminal. If you want to finish the inquiry and move to the upper menu, click [CLOSE] or [BACK] button. 3.9.4. User If you select the [Terminal info]->[User] in the main menu, the following window appears. . ▶User - User: The number of users registered (including administrator) - Admin: The number of the administrators registered. - FP: The number of all the fingerprints registered.
UBio-X Pro User Guide 3.9.5. Log If you select the [Terminal info] [Log] in the main menu, the following window appears. ▶Log Log: The number of logs saved in the terminal Image Log: The number of image logs saved in the terminal. (Max means the maximum number of items which can be saved in each item.
UBio-X Pro User Guide ▶View Log Log search result shows the information such as the date, time, ID and access result (success or failure). Click [BACK] or [NEXT] button to see the search information. If you want to finish the inquiry and move to the upper menu, click [Close] or [BACK] button. 3.9.6. About If you select the [Terminal info] -> [About] in the main menu, the following window appears. ▶About It shows the license information of the Korean font applied to the terminal.
UBio-X Pro User Guide 3.10. SD Card If you select the [SD Card] at the main menu, the following screen appears. < When the SD Card was inserted > < When the SD Card was not inserted > < When the SD Card was locked > ※ It works only if the SD Card is inserted, and it should be inserted with the back side face forward like the figure. (The side of the SD Card should not exceed 32G.) UNIONCOMMUNITY Co., Ltd.
UBio-X Pro User Guide It is the function used for data backup of the terminal by [Export], and you can copy the backup data from the [Export] into the terminal again. ▶ Export It copies the data from the terminal to the external SD Card. - User data: It copies the user DB to the folder ‘unisuser’ on the SD Card. - System option: The option setting value of the terminal is copied to the folder ‘UbioXpro / config’.
UBio-X Pro User Guide 73 - Picture: The image log data is saved in the folder ‘UbioXpro / Terminal ID (8digit) / log / pictures’ on the SD Card as jpg file. - Export all: It can export all things User Data, Event Log, System Option, Picture to the SD Card. ▶Import It copies the data from the SD Card to the terminal. - User Data: It copies the user DB from the SD Card to the folder ‘unisuser’ in the terminal.
UBio-X Pro User Guide 74 If you select the file type as ‘Background image file(.jpg)’, select the image file (.jpg), and click the ‘Send’ button, the terminal selection window appears. If you select the terminal in the terminal list window and click the ‘Send’ button again, the file is sent and the download result is represented. At this point, the file name should not exceed 15 letters (English, 15byte), and the jpg file whose size is jpg file only (size: 480*800) is only can be sent.
UBio-X Pro User Guide 75 3.12.2. BT module connection wait status In the active state, it is displayed as below. Displays the model name, master ID, and BT module MAC address of the recognizer. 3.12.3. Search and access your app’s BT module If you click Bluetooth search after login the app, BT module information will be searched as shown below. Select the BT module and try to connect. UNIONCOMMUNITY Co., Ltd.
UBio-X Pro User Guide 76 3.12.4. Connected app and BT module When the app BT module is connected, it will be displayed as the following figure. The app will say “Bluetooth connected” and the BT icon will turn on the recognizer screen as shown below. 3.12.5. Disconnect from app and BT module in recognizer If the BT module is connected to the app (the BT icon is displayed in blue), or you briefly touch the BT icon while BT is active, you will see “BT Disconnecting …”Will be Disconnected from the app.
UBio-X Pro User Guide 4. How to use terminal The background image and composition of the basic window can be changed according to the administrator’s setting. In addition, if the administrator set the screen saver time, the LCD screen is turned off automatically if there is no action for set time, and when the user accessed to the terminal, tried the authorization with fingerprint/card, or touched the main screen, the LCD screen is turned on automatically. 4.1.
UBio-X Pro User Guide 4.2. How to input user ID If you click the button [ID] on the basic window, following the window “Input User ID” as below. Enter the user ID to be certified and click [OK] button, then the input screen of fingerprint, face, card, or password according to the authorization method of the user. 4.3. How to authorize 4.3.1.
UBio-X Pro User Guide 4.3.2. Fingerprint authorization ▶1:N Authorization (Identification) If you put your fingerprint on the fingerprint sensor at the basic window, the fingerprint is entered with the light on the sensor with beeping. Do not take off your finger until the light of the sensor turns off completely.
UBio-X Pro User Guide 4.3.3. Card authorization Put the card on the card picture in 4.3.4. Password authorization Input your ID by clicking [ID input] button as follows and input password when the password input window appears. UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code : 05836) Tel : +82-2-6488-3000 , Fax : +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.
UBio-X Pro User Guide 81 4.3.5. Multi-mode authorization For user who needs to authenticate via more than 2 methods such as –card & fingerprint OR card & fingerprint & face, The preferential precedence of the authentication after the ID is typed is as follows: cardfingerprintfacepassword It activates even face or fingerprint authenticates firstly. UNIONCOMMUNITY Co., Ltd.
UBio-X Pro User Guide 82 FCC Information This device complies with part 15 of the FCC Results. Operation is subject to the following two conditions : (1) This Device may not cause harmful interface, and (2) This device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for CLASS B digital device, pursuant to Part 15 of FCC Rules.