UBio-X Iris.User Guide Version Eng-1.00 Copyright 2000 By UNIONCOMMUNITY Co., LTD.
UBio-X Iris User Guide Version Date Description Firmware Version 1.00 2020-06-09 Initial Release 0.0.1-61.00.000.01 UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code: 05836) Tel: +82-2-6488-3000, Fax: +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.
UBio-X Iris User Guide 3 Admin, Administrator - A user who can enter into the terminal menu mode, he/she can register/modify/delete terminal users and change the operating environment by changing settings. - If there is no administrator for a terminal, anyone can change the settings. In this regard, it is recommended to register at least one administrator.
UBio-X Iris User Guide Table of Contents .................................................................................................... 2 ................................................................................................................ 3 Table of Contents .................................................................................................... 4 1. Before use ....................................................................................
UBio-X Iris User Guide 5 3.6.1. System ......................................................................................................... 43 3.6.2. Finger ........................................................................................................... 45 3.6.3. Iris ................................................................................................................ 47 3.6.4. Auth .................................................................................................
UBio-X Iris User Guide 1. Before use 1.1. Safety Precautions Warning Handling with wet hands or allowing liquid to flow into it is prohibited. -> It may cause an electric shock or damage. Do not place a fire source near the terminal. -> It may cause a fire. Do not disassemble, repair, or modify the terminal at discretion. -> It may cause an electric shock, fire or damage. Keep out of reach of children. -> It may cause an accident or damage.
UBio-X Iris User Guide 1.2. Specific names of the terminal Microphone IR LED Dual camera Touch LCD Card sensing area Fingerprint sensor Illumination sensor Distant sensor USB memory input Speaker UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code: 05836) Tel: +82-2-6488-3000, Fax: +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.
UBio-X Iris User Guide 1.3. Windows after operation ID input button Menu button Select the access mode. Time/Date Status Icon 1.3.1. Icons None : There is no connected Wi-Fi dongle. : Wi-Fi connection is not activated ① Wi-Fi Status : Wi-Fi connection is activated ② Distance detection ③ Illumination detection None : When there is nothing in the proximity distance (90cm) : When there is a person within the proximity distance (90cm) None : Detect the high illumination status.
UBio-X Iris User Guide 1.3.2. Message - Basic Window - When the authentication succeeds - When the authentication is failed - When an unregistered user ID is entered - When an unregistered card is entered UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code: 05836) Tel: +82-2-6488-3000, Fax: +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.
UBio-X Iris User Guide - Passback error when using anti-passback function - When using for meal management - When a user tried the authentication more than twice in one meal time - When the server does not respond during the authentication attempt to the server - When the network is disconnected during the authentication attempt to the server - Registration without authentication right or authentication attempt when the entrance is not permitted When the user is designated in the blacklist UNIONCO
UBio-X Iris User Guide - When the terminal is set as locked When it is not the meal time in meal management - The waiting status for the input of user ID - The waiting status for the input of password - The waiting status for the input of fingerprint UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code: 05836) Tel: +82-2-6488-3000, Fax: +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.
UBio-X Iris User Guide - The waiting status for the input of card - When the terminal program is being upgraded (In this status, you should not turn off the terminal.) 1.4. Voice sounds in operation Operation type Voice sound Success to authorize You are authorized. Fail to authorize Please try again. 1.5.
UBio-X Iris User Guide 13 Notes - It is recommended to register and authorize at the location where the terminal is installed. - If you close your eyes or turn your eyes to the side, the iris recognition rate may decrease. It is recommended to locate the face at the front as far as possible - The color lenses or sun glasses can decrease the recognition rate of iris. Cautions in the installation - Be sure to install the terminal indoor. - Do not install under the light bulb.
UBio-X Iris User Guide 14 Be aware of certain fingerprint conditions Depending on the user’s fingerprint condition, some fingerprints may not be used or may cause an inconvenience. If the fingerprint is damaged or very unclear, it cannot be recognized. Please use a password instead in this case. When a finger is dry, breathe on the finger for smooth operation. For kids, it may be tricky or impossible to use the terminal since their fingerprints are too small or very unclear.
UBio-X Iris User Guide 2. Product introduction 2.1. Product characteristics Multi-Modal product which the user can use both iris and fingerprint authentication functions together. FHD (5M) Display resolution is applied. The illumination sensor and dual camera (Color & IR) are applied to enable the iris recognition even in the dark place. RF(125kHz) and Smart Card(13.56MHz) can be used at the same time.
UBio-X Iris User Guide Card & Password Card, password registration Password authentication after card authentication ID input > Card authentication > Password authentication Fingerprint or Password Fingerprint, password registration Fingerprint authentication Fingerprint authentication after ID input, if failed, Password authentication is possible.
UBio-X Iris User Guide Card & Fingerprint & Iris Card, fingerprint, iris registration Fingerprint and iris authentication after card authentication ID input > Card authentication > Fingerprint and authentication Fingerprint & Iris & Password Fingerprint, iris, password registration Iris and password authentication after fingerprint authentication ID input > Fingerprint authentication > Iris and Password authentication UNIONCOMMUNITY Co., Ltd.
UBio-X Iris User Guide 2.2. Product components 2.2.1. Standalone use (Access) DC15V Adapter Electric lock (Lock+, Lock-, Monitor) 2.2.2. Connected with Server (Access, Time & Attendance, Meal management) TCP/IP TCP/IP TCP/IP Internet / WAN / LAN TCP/IP TCP/IP TCP/IP UNIONCOMMUNITY Co., Ltd. Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu, Seoul, Korea (zip code: 05836) Tel: +82-2-6488-3000, Fax: +82-2-6488-3099, E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.
UBio-X Iris User Guide 2.3. Product specification Types SPEC CPU 1GHz Quad Core CPU LCD 5.
UBio-X Iris User Guide 3. Environment setting 3.1. Checks before setting the environment 3.1.1. Entering the menu If you click [ follows. ] icon at the basic window, you can see the main menu window as You can enter the subdivision menu by clicking each button. 3.1.2. Administrator authentication If the administrator is registered, the following administrator authentication window appears at first.
UBio-X Iris User Guide 3.1.3. How to enter the menu without administrator authentication It is how to enter the menu when the fingerprint or iris authentication is impossible since the administrator card registered in the terminal was lost or there is no administrator. ① Open the cover by removing the bracket at the backside of the terminal. ② With the opened cover, connect the 5 pin connector number 2 with 4, and 3 with 5 at the bottom of the backside of the terminal.
UBio-X Iris User Guide 22 3.1.4. How to save the set values If you click the [Complete] button at each menu to save the changed value after the change of settings, the set value of the window is saved and the following message box appears. ▶If there is no changed value, the window is moved to the previous menu. ▶If there is no signal for 30 seconds while changing the set value in the menu, the window is moved to the previous menu. UNIONCOMMUNITY Co., Ltd.
UBio-X Iris User Guide 3.2. Menu composition 1.User 1. 2. 3. 4. 5. Add Modify Delete Delete All View 2. Network IP address DNS Server IP Terminal ID 3. System 1. System Static IP / DHCP ▶IP address ▶Subnet Mask ▶Gateway ▶DNS server 1 ▶DNS server 2 ▶Server IP ▶Port ▶Terminal ID ▶User ID Length [2~9] ▶Authentication: Terminal Only ▶Mandatory Registration □Iris □Fingerprint □Card □Password □Name Number of fingers [1~10] 2.
UBio-X Iris User Guide 4. Application 5. Terminal 6. Database 1. 2. 3. 4. 5. 1. Application ▶Access / TnA / Meal 1. When setting ‘Access’ or ‘TnA’ ▶Schedule F1 (Attend) F2 (Leave) F3 (Out) F4 (In) Access ▶Blocking Time (0~86400) 2. When setting ‘Meal’ ▶Schedule Breakfast Lunch Dinner Supper Snack □ Allow duplicate 2. Function key □ □ □ □ □ 1. Sound ▶Voice Volume ▶Beep Volume ▶Sound Option 2. Option 3. Input 4.
UBio-X Iris User Guide 6. Display 5. External Device ▶RS232 ▶RS485 ▶Wiegand Site Code Wiegand Output Wiegand Input 1. Theme ▶Background 2. Camera 3. Language 4. Option 7. Info ▶Language ▶Screen saver ▶Display Option 5. Message display ▶Message Display time Time (ms) 1. System 2. Terminal ▶System Info ▶Disk ▶Ram ▶Terminal Info Terminal ID Application Language 3. Network ▶Network Info MAC IP 4. User ▶User 5. Log 6. About 8.
UBio-X Iris User Guide 3.3. User Management When you select the [User] at the main menu, the following window appears. The number of all the users is shown at the top of screen including administrator. Click [Add] button to add the new user, [Modify] button to modify the user, [Delete] button to delete the specific user, [Delete All] button to delete all the users, and [View] button to inquire the registered user list. 3.3.1.
UBio-X Iris User Guide The icons in the left side mean as follows: : The number of registered irises : The number of registered fingerprints (X,1~10) : Existence of password registration (X: none, O: registered) : The number of registered cards (X,1~10) : The user ID to register : User : Administrator it.
UBio-X Iris User Guide 3.3.1.1. Photo registration Register by clicking [ [Add User] screen. ] button at the Click [Save] button to register with the present camera image. Click [Cancel] or [BACK] button to cancel the registration and return. 3.3.1.2. Name registration Register by clicking [Name] button in the [Add User] screen. After entering name with the keyboard at the bottom, click [OK] button. Click the [ ] button to cancel the registration and return. 3.3.1.3.
UBio-X Iris User Guide ※When you authenticate with duress FP, the alarm message can be transferred to the server and you can output the dry contact signal if you set the duress FP alarm from the setting of lock from the terminal menu. (Refer to ‘3.7.4. Lock’). ② Enter the fingerprint with referring ‘1.7 Proper fingerprint registration and input methods’. Enter the fingerprint twice according to the screen instruction as follows.
UBio-X Iris User Guide If it is similar with the fingerprint already registered, the message “Already registered finger!” appears like the left side, and you can start again from the procedure of ② if you click the [Retry] button. You can click [ ] button to cancel and return to the previous menu. ※ You can register 10 fingerprints at most for one ID, and you cannot register more than 10 IDs.
UBio-X Iris User Guide ③ When the registration is completed, ‘Completed’ message is shown on the screen. If you click [OK] button, the iris registration is completed and the screen is moved to the previous screen. If you want to register again, click [Start] button to start from the procedure of ②.
UBio-X Iris User Guide 3.3.1.5. Password registration If you enter the password in 1~8 digits in the password input window and click [OK] button, the input focus is moved to the ‘password confirmation’ window at below. Enter the same password again and click [OK] button. Click [ ] button to cancel and return. ※If you enter the different password in the confirm window, the message “Wrong input!” appears as follows. 3.3.1.6.
UBio-X Iris User Guide 3.3.1.7. Authentication option ▶’FP Level’ (Basic setting: ’0’) It decides the fingerprint authentication level of each user, and the registered users can have different authentication level by modifying this value. If you set ‘0’, the authentication uses the level of fingerprint authentication. For example, if you select the ‘1’ for FP Level, this user will be applied with “1” on 1:1 FP Level.
UBio-X Iris User Guide 3.3.1.8. Auth type Set by clicking [Auth type] at the [Add User] window. (But, it can be set when there are more than 2 authentication methods registered) Click [BACK] button to cancel and return. This shows all the authentication methods already registered, and the buttons at the lower side shows the buttons [OR] / [AND] which can be selected. The selected authentication method is displayed by blue and the registered or non-used authentication method does by gray.
UBio-X Iris User Guide When you click the [Save] button, the case that the user fails to register : The case none of authentication methods such as fingerprint, iris, card or password is registered. When you click the [Auth Method] button, the case none of authentication method is registered In [Register FP], the case you input the different fingerprint at the fingerprint registration. In [Register FP], the case you tried to register the fingerprint already registered.
UBio-X Iris User Guide 3.3.2. Delete The following window appears if you click [User] [Delete] at the main menu. Input the user ID to be deleted and click [OK] button. Click [BACK] button to cancel and return. If you input the unregistered ID, the failure message “Unregistered user” appears, and if you input the registered ID, the success message “Deleted” appears.
UBio-X Iris User Guide 3.3.3. Modify The following window appears if you click the [User] [Modify] in the main menu. Input the user ID to be modified and click [OK] button. Click [BACK] button to cancel and return. The failure message appears if you input the unregistered ID, and if you input the registered ID, the information of registered user is represented as follows: The icons at the left side means as follows.
UBio-X Iris User Guide 3.3.4. Delete All If you click the [User] [Delete All] in the main menu, the following window appears. If you want to delete all the users, click [YES], and if you want to cancel, click [NO]. ※If you click [YES], the users and admin are deleted, and the restoration is impossible once they are deleted, so be careful. 3.3.5. View If you click the [User] -> [View] in the main menu, all the users registered can be searched as follows.
UBio-X Iris User Guide ▶[ID]: If you input the User ID by clicking [ID] button, the user is searched like in the left picture. If you click [BACK] button in this window, you can move to the ‘3.3. User Management’ menu. ▶[Name]: If you input the user name by clicking [Name] button, the registered user list including the characters is shown. If you click [BACK] button in this window, you can move to the ‘3.3. User management’ menu.
UBio-X Iris User Guide ▶[Port]: The basic port value of the authentication server (UNIS server) is ‘9870’, and if you change the value, you should change the server program with the same value, so be cautious. ▶[Terminal ID]: It is a unique ID used for the terminal to distinguish the terminals and the default value is ‘1’. It should be the same with the ID of the terminal registered in the server program and the characters can be set up to 9 digits for maximum.
UBio-X Iris User Guide 3.5. Application mode 3.5.1. Application If you select the [Application] in the main menu, the following window appears. In the application mode, you can select the [Access / TnA / Meal] according to the purpose. 3.5.1.1. Access or TnA setting It is the screen showing when you select ‘Access’. Click [OK] button to apply the changes, and click [BACK] button to cancel and return. ▶Basic setting : Same with the window at the left side. It is the screen showing when you select ‘TnA’.
UBio-X Iris User Guide 3.5.1.2. Meal setting It is the screen showing when selecting the meal management. You can set the time period of each meal type. And if the setting is not needed, set ‘00:0000:00’. ▶ Allow duplicate : If it is unchecked ( ), each user can authorize once in the one meal, but if it is checked ( ), the multiple authentication is possible regardless of the previous authentications. Click [OK] button to apply the changes, and click [BACK] button to cancel and return. 3.5.2.
UBio-X Iris User Guide 3.6. System 3.6.1. System The following window appears if you select the [System] [System] in the main menu. ▶Basic setting: Same with the window at the left side ▶User ID Length It sets the length of the user ID, and it can be 2~9 digits and should be the same with the length of the registered ID of the server program. If the ID registered in the server program uses ‘000075’ as a 6 digits ID, set 6.
UBio-X Iris User Guide 44 ▶Mandatory Registration It determines the items which should be entered in the user registration, and the user can be registered when all the checked items are entered. The number of registered fingerprints is only valid when the [Fingerprint] is checked. Click [OK] button to apply the set value, and click [BACK] button to cancel and return. If you click the [OK] button without changing the set value, it is moved to the previous menu directly.
UBio-X Iris User Guide 3.6.2. Finger The following screen appears if you select the [System] -> [Finger] in the main menu. ▶Basic setting: Same with the window at the left side ▶1:N Level (3~9) It is the authentication level used in the 1:N Fingerprint authentication. In case of 1:N authentication, the authentication level is not set for each user, so the authentication level of the terminal is always the standard.
UBio-X Iris User Guide If you click the [YES] button, the new format is applied, and if you click the [NO] button, the format value before the change is maintained. ※ Notes If you change the fingerprint template format, all the registered fingerprints are deleted, so be cautions. ▶Check similar FP ), the re-registration as another user ID is prevented by checking if If it is checked ( the fingerprint is already registered. Similar fingerprints are checked against users who ticked the 1:N option.
UBio-X Iris User Guide 3.6.3. Iris ▶Basic setting: Same with the window at the left side ▶Matching Level It is the level used in iris authentication, and it can be set 1~5 levels according to the accordance degree with the registered iris. And the authentication is successful when the accordance degree is higher than the set authentication level.
UBio-X Iris User Guide ▶ Auth Type: Select the authentication method of the terminal. - Card: Even if the user is registered with the authentication method requiring the iris, fingerprint or password with the card, you can authenticate only with the card in the terminal that this option is checked. For the fingerprint, iris, or password users, they can authenticate as their authentication method.
UBio-X Iris User Guide ▶Display Format It is the method to indicate the current time of terminal. - yyyy-mm-dd: It shows as the order of year, month, and date. - dd-mm-yyyy: Order of date, month (English), and year. ▶ Set Date / Set Time It changes the current time of the terminal. If the server is connected and the [Time synchronization] is set [Auto], you don’t have to change since it is synchronized with the server time.
UBio-X Iris User Guide If deletion is succeeded by clicking [YES], the following success message box appears. In this case, both the users and administrator are deleted, and the restoration is impossible once the data is deleted. 3.6.6.2. Delete setting If you select the [System] [Database] [Delete setting] in the main menu, the following screen appears. Click [YES] button to initialize all the set values, and click [NO] or [ ] button to cancel.
UBio-X Iris User Guide 3.6.6.3. Delete Log If you select the [System] [Database] [Delete log] in the main menu, the following window appears. If you want to delete all the authentication record in the terminal, click [YES] button, and if you want to cancel, click the [NO] or [ ] button. If there is no signal for 5 seconds in this state, the message box disappears without deletion. If it is deleted successfully by clicking [YES], the success message in [Fig. 3-5] is displayed.
UBio-X Iris User Guide 3.6.6.5. Factory init If you select the [System] [Database] [Factory init] in the main menu, the following window appears. If you want to initialize the terminal in the factory setting, click [YES] button, and if you want to cancel, click [NO] or [ ] button. If there is no signal for 5 seconds in this state, the message box disappears without initialization. If it is deleted successfully by clicking [YES], the success message in
UBio-X Iris User Guide 3.7. Terminal 3.7.1. Sound If you select the [Terminal] [Sound] in the main menu, the following window appears. ▶Basic setting: Same with the window at the left side. ▶Voice Volume Scroll from side to side in 0~15 degrees to set the voice volume. If you click the [ ] button at the right side, the voice is played to check the volume. ▶Beep Volume Scroll from side to side in 0~3 degrees to set the beep volume.
UBio-X Iris User Guide 3.7.2. Option If you select the [Terminal] [Option] in the main menu, the following window appears. ▶ Basic setting: Same with the window at the left side ▶Read Card number: If the user places the card in this screen, the card number is displayed on the LCD. You can change the [Card format] to check the card number according to the set value.
UBio-X Iris User Guide [SC card example] Card number (4byte): 52h 9Dh 06h E3h Card format Card number Expression Standard 529D06E3 8 digits hexadecimal Hexadecimal E3069D52 8 digits hexadecimal with changing the order of byte 10 Digit Decimal 1386022627 hexadecimal 529D06E3: 10 digits decimal 3,5 Digit Decimal 3808861522 hexadecimal E3069D52: 10 digits decimal 6 Digit Hexadecimal 069D52 Locate the foremost 3bytes backwards.
UBio-X Iris User Guide is connected. - Emergency Monitor NO or Emergency Monitor NC: When the emergency situation detection sensor is connected. Set NO/NC according to the state of pin input in detection. ▶ IO: Set when connecting the external access point to the Exit pin. - None: When nothing is connected - Inside Open NO or Inside Open NC: When the exit button was connected - Fire Monitor NO or Fire Monitor NC: When the fire detection sensor is connected.
UBio-X Iris User Guide ▶Lock 1 Option - None: When it is not used - Strike/Auto/OK: When the warning light is connected to indicate the strike type, auto door, or authentication success/failure on Lock1. - Motor Lock 1: When the motor lock is connected. - Schedule alarm: When the siren setting of the terminal option was sent to the terminal, it sends the operating signal about it.
UBio-X Iris User Guide authentication mode are printed by the printer connected to the RS232 port. The printing format differs as per the setting, and when setting as [Ticket Format 2] the ‘text for meal printer’ which is set from the terminal option, becomes the title on the top side. The printer used to print ticket is “SRP-350” serial type model. ▶ RS485: It sets the connecting device to RS485 port. - None: When there is no device connected to RS485. - LC010: When LC010 is connected.
UBio-X Iris User Guide 3.8. Display 3.8.1. Theme If you select [Display] [Theme] in the main menu, the following window appears. ▶Basic setting: Same with the window at the left side ▶Background Set the back ground in the main screen. Select [ ] button to see the next image. Click [OK] button to apply the set value, and click [BACK] button to cancel and return. If you want to set other items, select the button for that item. 3.8.2.
UBio-X Iris User Guide 3.8.3. Language If you select the [Display] [Language] in the main menu, the following window appears. ▶Basic setting: ‘English’ ▶Language If you change the language and click [OK] button, the voice message and language are changed to the set language. If you want to cancel and move to the upper menu, click [BACK] button. ※ Supported languages English, Korean, Japanese, Portuguese, Chinese(Traditional), French, Chinese(Simplified), Spanish, Polish, Persian, German 3.8.4.
UBio-X Iris User Guide 3.8.5. Message display time If you select the [Display] [Message display time] in the main menu, the following window appears. ▶Basic setting: Same with the window at the left side. ▶Message Display (ms) It sets the time that the authentication window is displayed. 0~5000 is available for the value, and the authentication result window appeared and disappear for the duration. Because it is set in millisecond, if you want to set 2 seconds, you should set 2000.
UBio-X Iris User Guide 3.9.2. Terminal If you click the [Terminal info] [Terminal] in the main menu, the following window appears. ▶Terminal info It represents the option setting value of the terminal. Click [Close] or [BACK] button to finish the inquiry and move to the upper menu. 3.9.3. Network If you select the [Terminal info] [Network] in the main menu, the following window appears. ▶Network info It shows the setting value of the terminal.
UBio-X Iris User Guide 3.9.4. User If you select the [Terminal info]->[User] in the main menu, the following window appears. ▶ User - User: The number of users registered (including administrator) - Admin: The number of the administrators registered. - FP: The number of all the fingerprints registered.
UBio-X Iris User Guide ▶ Log Search To search log, follow the following steps, [Terminal Info] [Log] [View Log] [Log Search]. And then set the Start Date, End Date and Event criteria and click [OK]. ▶ View Log Log search result shows the information such as the date, time, ID and access result (success or failure). Click [BACK] or [NEXT] button to see the search information. If you want to finish the inquiry and move to the previous menu, click [Close] or [BACK] button. 3.9.6.
UBio-X Iris User Guide 3.10. USB If you select [USB] in the main menu, the following screen appears. ※ This operation is available only when USB memory is inserted. In case of some USB memory, since it cannot be recognized, please use the other USB memory in this case. It is the feature to back up the data of the terminal via [Export]. You can copy the back-up data to the terminal via [Import].
UBio-X Iris User Guide It can set the period to copy the event log. - Picture: The image log is saved in the folder of ‘UbioXiris/Terminal ID (8 digits)/log/pictures’ in USB memory as .jpg file. - Export All: It can export all of them, specifically the user data, system option, event log to the folder of USB memory. ▶ Import It copies the data from the USB memory to the terminal. - User Data: It copies the user DB from the USB memory to the folder ‘unisuser’ in the terminal.
UBio-X Iris User Guide 67 3.11. Download the user file If needed, it is the feature that the user can change the background and voice message. You can copy it by using USB memory or change the user file by downloading it from UNIS server program. 3.11.1. Change the voice message If you select the ‘Download customized file’ in the UNIS program, the following window appears. If you select ‘Success Voice File (.wav)’ as the file type and click ‘Send’ button after selecting the sound file (.
UBio-X Iris User Guide 4. How to use the terminal The background image and composition of the basic window can be changed depending on the administrator’s setting. In addition, if the administrator sets the screen saver time, the LCD screen is turned off automatically if there is no action for set time, and when the user accessed to the terminal, tried the authentication with fingerprint/card, or touched the main screen, the LCD screen is automatically activated. 4.1.
UBio-X Iris User Guide The status that is not selected The status that is selected 4.2. How to input the user ID If you click the button [ID] on the basic window, following the window “Input User ID” as below. Enter the user ID to authenticate and click [OK] button, then the input screen of fingerprint, iris, card or password is displayed. 4.3. Authentication 4.3.1. Iris authentication ▶1:N Authentication (Identification) Locate your eyes in the LCD guideline until the guideline changes to blue.
UBio-X Iris User Guide 4.3.2. Fingerprint authentication ▶1:N Authentication (Identification) If you put your fingerprint on the fingerprint sensor at the basic window, the fingerprint is entered with the light on the sensor with beeping. Do not take off your finger until the light of the sensor turns off completely.
UBio-X Iris User Guide 71 FCC Information This device complies with part 15 of the FCC Results. Operation is subject to the following two conditions : (1) This Device may not cause harmful interface, and (2) This device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for CLASS B digital device, pursuant to Part 15 of FCC Rules.
UBio-X Iris User Guide 72 “CAUTION : Exposure to Radio Frequency Radiation. Antenna shall be mounted in such a manner to minimize the potential for human contact during normal operation. The antenna should not be contacted during operation to avoid the possibilityof exceeding the FCC radio frequency exposure limit. Contains FCC ID: 2AEEY-PBLN51822M UNIONCOMMUNITY Co., Ltd.