AC-2100 Plus. USER GUIDE Version ENG-1.00 Copyright 2000 By Union Community Co., LTD.
AC-2100 Plus 사용자 가이드 2 Version Date Description Firmware Version 1.00 2016-12-28 -Initial Release 10.61.00-000.00 UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.
AC-2100 Plus 사용자 가이드 3 Administrator (Admin) - The administrator can access to the terminal menu mode. He/she has the authority to add/modify/delete terminal users and to change the operating environment by changing settings. - If there is no registered administrator in the terminal, anybody can access to the terminal menu and change settings. It is recommended that more than one administrator will be necessarily registered in the terminal.
AC-2100 Plus 사용자 가이드 4 Table of Contents .................................................................................................... 2 ............................................................................................................... 3 Table of Contents ........................................................................................................ 4 1. Before Getting Started ......................................................................
AC-2100 Plus 사용자 가이드 5 3.7.2. Card Number Inquiry ............................................................................. 56 3.7.3. Monitor Input Port Setting ...................................................................... 57 3.7.4. Duress FP Setting................................................................................... 58 3.8. Device Setting ............................................................................................... 59 3.8.1. System Configuration .............
AC-2100 Plus 사용자 가이드 6 1. Before Getting Started 1.1. Safety Notes Warning Do not operate the terminal with wet hands, and pay attention not to let any liquid such as water enter inside the terminal. → Otherwise, malfunction or electric shock may be caused. Keep the terminal away from inflammables. → Otherwise, it may cause a fire. Do not disassemble, repair or Do not allow children to remodel the terminal at your touch the terminal carelessly. disposal.
AC-2100 Plus 사용자 가이드 7 1.2. Product Details Status LED 1.77inch TFT LCD (128*160) Touch Key FP Sensor Smart Card UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.
AC-2100 Plus 사용자 가이드 8 1.3. Buttons displayed during operation F1 F2 - Switch to ‘Attend’ mode from the default screen. - Used to move up or increase [↑] in the menu mode - Switch to ‘Leave’ mode from the default screen. - Used to move down or decrease [↓] in the menu mode. - Switch to ‘Outdoor’ mode from the default screen. - When pressing for more than 2 seconds, you enter the menu mode: F3 [F3~] - Used to escape [ESC] or move left [] in the menu mode.
AC-2100 Plus 사용자 가이드 9 1.5.1. Icon Information ① Fire Detection A fire is detected by the fire detection sensor. ② Door Status Doors open state (forced open door or open the door when leaving). ③ Server Connection Status The LAN cable is not connected. Only Link is connected. ④ USB Connection The USB is connected. 1.5.2. Message Information - The default screen of AC2100 - The fingerprint is being input or on standby. - When authentication is successful UNIONCOMMUNITY Co., Ltd.
AC-2100 Plus 사용자 가이드 10 - When authentication fails - When fingerprint input fails If your finger is released too early before your fingerprint is entered - When an unregistered card is swiped When 1:N Authentication is attempted under the condition that authentication priority is SN and there is no user who has been allowed for 1:N Authentication - When anti-passback is in error - When the server cannot handle too many authentication requests from the terminal UNIONCOMMUNITY Co., Ltd.
AC-2100 Plus 사용자 가이드 11 - When the terminal is set to the food service control and users attempt more than two times authentication in the same food time zone - When there is no response from the server during authentication attempt When the network is disconnected during authentication attempt to the server - The card input is on standby.
AC-2100 Plus 사용자 가이드 12 - - When the terminal is locked When the food service control is set in the non-meal time When the terminal program is upgraded (Do not power off the terminal when this message is displayed.) UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr http://www.unioncomm.co.
AC-2100 Plus 사용자 가이드 13 1.6. Voice guide announced during operation Item Voice Guide When the fingerprint is entered Please enter your fingerprint. When authentication is successful You are authorized. When authentication fails Please try again. 1.7.
AC-2100 Plus 사용자 가이드 14 Precautions subject to your fingerprint status The availability of the fingerprint may vary subject to your fingerprint status. This product consists of a fingerprint recognition system and cannot recognize the damaged or unclear fingerprints. They should be registered using a password. If your hands are dry, you can blow your breath on the system to operate it more smoothly. For children, too small or unclear fingerprints may be difficult or impossible to use.
AC-2100 Plus 사용자 가이드 15 2. Product Description 2.1. Product Features Access control system using the network (LAN) - The fingerprint reader communicates with the authentication server using a UTP cable and TCP/IP protocol. This terminal can be applied to the existing LAN network and has easy expandability. It ensures a fast speed by 10/100 Mbps Auto Detect and facilitates management and monitoring via the network.
AC-2100 Plus 사용자 가이드 16 Various registration and authentication methods There are a total of four registration and authentication methods for general users. Before registering users or administrators, you should determine how to register and authenticate.
AC-2100 Plus 사용자 가이드 17 2.2. Configuration Diagram 2.2.1. Standalone Use (Access) DC12V Adapter (Lock+, Lock-, Monitor) 전기정 2.2.2. Connecting the PC server (Access, T&A, Food Service Control) TCP/IP TCP/IP TCP/IP Internet / WAN / LAN TCP/IP Fingerprint Authentication Server (Static IP) UDB Sever Database (MDB or MSSQL) Remote Administrator Program (User and Terminal Setting Management) TCP/IP Food Service Control Program TCP/IP Attendance Control Program UNIONCOMMUNITY Co., Ltd.
AC-2100 Plus 사용자 가이드 18 2.3. Product Specification 구 분 CPU SPEC REMARK 32 bits RISC CPU(400MHz) 64M SDRAM MEMORY 32M NOR FLASH 128M NAND FLASH Fingerprint Sensor Optical Authentication Speed Less than 1 second Scan Area / Resolution 12.6 * 14.8mm / 500 DPI FRR / FAR 0.1% / 0.0001% TCP/IP RS-232 Communication Port RS-485 Wiegand In/Out Temperature / Humidity -20 ~ 60 / Lower than 90% RH LCD 1.
AC-2100 Plus 사용자 가이드 19 3. Environment Setting 3.1. Checkpoints before environment setting 3.1.1. Enter the menu When pressing [F3] button for more than 2 seconds, the administrator authentication screen will be displayed. The administrator is verified by either card or fingerprint depending on the authentication method. Upon successful authentication, the screen goes to the following menu.
AC-2100 Plus 사용자 가이드 20 ※ The administrator authentication menus is displayed only when there is any registered administrator. Once it is authenticated to enter the menu mode, you can access to all menus until you escape completely from the main menu. 3.1.2. Modify settings Modify the existing settings by pressing [↑][↓] buttons. If the set value is greater than or equal to 2 digits, press [←][→] buttons to move to the digit you want to change, and press [↑][↓] buttons to change the value up or down.
AC-2100 Plus 사용자 가이드 21 3.2. Menu Configuration 1. User 1. 2. 3. 4. 5. 2. Network 1. Terminal ID :NS/SN/NO/SO 2. Terminal Net 3. Server Net 1. Application 1. Access 2. T&A 3. Cafeteria 3.
AC-2100 Plus 사용자 가이드 22 2. Verify
AC-2100 Plus 사용자 가이드 4.
AC-2100 Plus 사용자 가이드 5. Ext Function 6. Device 24 1. Lock Term 2. Read Card 3. Monitor 4. Duress FP 1. Sys Config 2. Card Format 3. FP-Sensor <1:1 Level> <1:n Level> 4. Wiegand 5. Initialize 6.Ext Device UNIONCOMMUNITY Co., Ltd.
AC-2100 Plus 사용자 가이드 25 3.3. User Management Select [1.User] on the main menu, and the following screen will appear. Press [↑][↓] buttons to select the menu you want to change, and press [ENT] button. 3.3.1. Add User Select [F3~]→[1.User]→[1.Add User] on the main screen, and the following screen will appear. Enter the ID of the new user you wish to register, and press [F4] button long. When registering, the available user ID is automatically displayed on the LCD so that you can register it conveniently.
AC-2100 Plus 사용자 가이드 26 3.3.1.1. Register as “1. FP” Register and authenticate using the fingerprint. Default Setting: ‘0’ This screen is available to determine the authentication level for each user to be registered. By changing this value, the different authentication level may be set for each registered user. If this value is set to ‘0’, the 1:1 Level set in the terminal is used instead of the user-specific authentication level.
AC-2100 Plus 사용자 가이드 27 It should be noted that when entering the second fingerprint after entering the first fingerprint, you must release your finger from the fingerprint input window and then enter the second fingerprint again. When the registration is completed, select “Add FP”. If it fails, the screen returns to the “1. User” screen. The followings show LCD prompts that may appear during the registration process.
AC-2100 Plus 사용자 가이드 28 3.3.1.4. Register with “FP and Card” The user can be registered using card and fingerprint. Authentication is performed for the card and then for the fingerprint. The user should register his/her fingerprint (see Fingerprint Registration) and then his/her card (see Card Registration). 3.3.2. Delete User Select [F3~]→[1.User]→[2.Delete] on the main screen, and the following screen will appear. Enter the ID of the new user you wish to delete, and press [F4] button long.
AC-2100 Plus 사용자 가이드 29 3.3.3. Modify User Select [F3~]→[1.User]→[3.Modify] on the main screen, and the following screen will appear. Enter the ID of the user you wish to change, and press [ENT] button long. Both general users and administrators can be changed without distinction. If the ID of an unregistered user (or administrator) is entered, the message of “Unregister” with “Fail” buzzer is displayed on the LCD and then the screen goes to the “1. User” menu.
AC-2100 Plus 사용자 가이드 30 To modify, select the authentication methods referring to the aforementioned process of [3.3.1.1] to [3.3.1.4]. [2] When selecting “1:1 Level” Recommended Setting: ‘0’ To modify, the new set value should be entered. If this value is set to ‘0’, the 1:1 Level set in the terminal is used instead of the user-specific authentication level. [3] When selecting “Add FP” Enter your fingerprint referring to “1.8. How to register and enter the fingerprint” as aforesaid.
AC-2100 Plus 사용자 가이드 31 fingerprint again. When the registration is completed, select “Add FP”. If it fails, the screen returns to the “3. Modify” menu. The followings show LCD prompts that may appear during the registration process.
AC-2100 Plus 사용자 가이드 32 3.3.4. Add Administrator Select [F3~]→[1.User]→[4.Add Admin] on the main screen, and the following screen will appear. Enter the ID of the administrator you wish to register, and press [F4] button long. ※ Since then, the administrator registration process is same as the general user registration process.
AC-2100 Plus 사용자 가이드 33 3.4. Network Setting Select [2.Network] on the main menu, and the following screen will appear. Press [↑][↓] buttons to select the menu you want to change, and press [ENT] button. 3.4.1. Terminal ID Select [F3~]→[2.Network] → [1.Terminal ID] on the main screen, and the following screen will appear. 3.4.1.1. Terminal ID This ID is a unique ID used to allow the server to identify the terminal. The default is ‘00000001’.
AC-2100 Plus 사용자 가이드 34 This menu is to determine the authentication priority between the terminal and the network, the default is ‘2. SN’, and the authentication method in each mode operates as follows. NS If the terminal is connected to the server, authentication is attempted from the server. If the terminal is disconnected from the server due to a network failure, etc., authentication is attempted from the terminal.
AC-2100 Plus 사용자 가이드 35 3.4.2. IP Setting Select [F3~]→[2.Network] → [2.Terminal Net] on the main screen, and the following screen will appear. 3.4.2.1. Connection Method Setting Select [1] if Static IP is assigned, and select [2] to set IP using DHCP. Default Setting: ‘1.Static’ This refers to how the terminal is connected to the network. The default is ‘1’ (Static).
AC-2100 Plus 사용자 가이드 36 3.4.2.3. Subnet Mask Setting Press [←][→] buttons to move to the digit you want to change, and press [↑][↓] buttons to change the numbers. Default Setting: “255.255.255.000” This is to set the subnet mask of the network connected to the terminal. After entering correctly, press [F4] button long to move to the next setting. 3.4.2.4. Gateway Setting Press [←][→] buttons to move to the digit you want to change, and press [↑][↓] buttons to change the numbers. Default Setting: “192.
AC-2100 Plus 사용자 가이드 37 3.4.3.1. Connection Method Setting Select [1] if Static IP is assigned, and select [2] to set IP using DDNS. Default Setting: ‘1.Static’ This is the way that the terminal is connected to the network. Select [1] when using the Static IP assigned from the connected network, and select [2] when using the IP assigned from the DDNS server. After entering correctly, press [ENT] button to move to the next setting.
AC-2100 Plus 사용자 가이드 38 3.4.3.3. Sever Port Setting Press [←][→] buttons to move to the digit you want to change, and press [↑][↓] buttons to change the numbers. Default Setting: “09870” This is to specify the Port of the network server connected to the terminal. After entering correctly, press [F4] button long, and the screen will go to the upper menu. 3.4.3.4. DDNS ID Setting Press [←][→] buttons to move to the digit you want to change, and press [↑][↓] buttons to change the numbers.
AC-2100 Plus 사용자 가이드 39 3.4.3.5. DDNS IP Setting Press [←][→] buttons to move to the digit you want to change, and press [↑][↓] buttons to change the numbers. Default Setting: “210.116.104.058” This is to specify the IP Address of the network server connected to the terminal. After entering correctly, press [F4] button long to move to the next setting. 3.4.3.6. DDNS Port Setting Press [←][→] buttons to move to the digit you want to change, and press [↑][↓] buttons to change the numbers.
AC-2100 Plus 사용자 가이드 40 3.5. Option Setting Select [3.Option] on the main menu, and the following screen will appear. Press [↑][↓] buttons to select the menu you want to change, and press [ENT] button. 3.5.1. Application Setting Select [F3~] → [3.Option] → [1. Application] on the main screen, and the following screen will appear. Set the operating mode that you want to set. Default Setting: ‘1.Access’ This is to set an operating mode of the terminal.
AC-2100 Plus 사용자 가이드 41 3.5.1.1. When setting to “[1.Access]” or “[2.T&A]” By setting the default time for each T&A mode, after authentication, the terminal display mode can be turned into the automatically set T&A mode. If time setting is unnecessary, it is set to ‘00:00-00:00’. This is to set the default attendance time. Press [←][→] buttons to move to the digit you want to change, and press [↑][↓] buttons to change the numbers.
AC-2100 Plus 사용자 가이드 42 Default: ‘1.No’ This is the menu to select whether to use the printer or not. If the authentication is set to ‘1’ or ‘2’ with successful authentication, the Terminal ID, User ID, Date and Authentication mode are printed out through the printer connected to the RS232 port of Terminal. The printer used is “SRP-350” Serial Type model. Subsequently, press [ENT] button, and the following screen will appear. Default Setting: All ‘V’ Set whether to use each function key.
AC-2100 Plus 사용자 가이드 43 3.5.1.2. When setting to “[3.Cafeteria]” If time setting is unnecessary, it is set to ‘00:00-00:00’. This is to set the breakfast time. Breakfast is unconditionally authenticated within the set time zone. After setting the breakfast time, set , , , and in order in the same way. The unused meal time is set to ‘00:00-00:00’. Each time zone must be set not to overlap each other.
AC-2100 Plus 사용자 가이드 44 When is set, the menu to check whether to duplicate appears as shown below. Default Setting: ‘2.No’ If the mode is set to ‘No’, authentication is once allowed within the same meal time zone. When attempting authentication again, the “Duplicated!” message is displayed and the authentication fails. Subsequently, press [ENT] button, and the following screen will appear. Default: ‘1.No’ This is the menu to select whether to use the printer or not.
AC-2100 Plus 사용자 가이드 45 Set whether to use each function key. When setting to ‘V’, it means that the authentication mode may be changed when pressing the function key. When setting to Blank, the authentication mode is not changed in spite of pressing the key. When this mode is used only for Attend or Leave, it is available by unchecking other function keys. After selecting the set value, press [ENT] button, and all authentication settings will be finished and the screen will move to the upper menu. 3.5.
AC-2100 Plus 사용자 가이드 46 3.5.2.2. Set whether to permit authentication using card only Default Setting: ‘2.No’ This option makes it possible to authenticate using card only without fingerprint. Even if the user is registered in FP and Card, he/she can be authenticated using card only in the terminal that this option is set to ‘1’. After selecting the set value, press [ENT] button, and the screen will go to the upper menu. 3.5.2.3.
AC-2100 Plus 사용자 가이드 47 3.5.2.4. Blocking Time Setting Default Setting: 00000 (Unit: Second) This option is to prohibit the user from re-authenticating within the set time. There is no limit when the mode is set to '0'. However, if it is set to the greater value than ‘0’, re-authentication cannot be permitted until the time lapses more than the set time after successful authentication. After selecting the set value, press [ENT] button, and the screen will go to the upper menu. 3.5.2.5.
AC-2100 Plus 사용자 가이드 48 3.5.2.6. NetErr TimeOut – Network Error Time Setting (Second) Default Setting: ‘05’ In the server authentication mode, if the network error time is set, the time to wait for authentication can be set. For example, if the error time is set to 5 seconds, when the user does not receive any response from the server for 5 seconds after authentication request, an error message comes out. (However, the user is processed as authentication failure.
AC-2100 Plus 사용자 가이드 49 3.5.3. Door Setting Select [F3~] → [3.Option] → [3.Doorlock] on the main screen, and the following screen will appear. 3.5.3.1. Door Open Time Setting Default Setting: ‘03’(Unit: Second) This option is to specify the time when after authentication through the terminal, the door is opened and then closed. Strike type means the time when if opening the door after authentication, the door is automatically locked again.
AC-2100 Plus 사용자 가이드 50 To use this function, the lock must have the function to monitor whether the door is open or close. The monitoring pin of the lock must be also connected to the terminal. To check whether the door is open or close, the mode must be set to ‘2’ or ‘3’. After selecting the set value, press [F4] button long, and the screen will finish all the setting of the door and move to the upper menu. 3.5.4. Volume Setting Select [F3~] → [3.Option] → [4.
AC-2100 Plus 사용자 가이드 51 3.5.4.2. Buzzer Volume Setting Default Setting: ‘3’ This option is to set the terminal buzzer volume. The buzzer occurs silent for ‘0’, small volume for ‘1’, and large volume for ‘3’. Press [ENT] button to move to the next setting. 3.5.4.3. Case Open Alarm Setting Default Setting: ‘1.Yes’ This option is to set whether an alarm occurs when the terminal case is open. The alarm occurs for ‘1’ and it does not occur not for ‘2’.
AC-2100 Plus 사용자 가이드 52 This option is to set how to synchronize the current time of the terminal with the server time. Set to ‘1.Auto’ to automatically synchronize with server time, and set to ‘2.Manual’ to manually synchronize with server time. Press [ENT] button to move to the next setting. 3.5.6.2. Calendar Setting Default Setting: ‘1.Gregorian’ This option is to set how to display the current date in the terminal. The date is generally set to ‘1. Gregorian’, but ‘2.
AC-2100 Plus 사용자 가이드 53 3.5.6.3. Current Time Setting The current time of the terminal is displayed in the order of "2009:Year, 08:Month, 01:Day, 21:Hour, 18:Min, 06:Sec". To modify, move to the desired position using [←][→] buttons, and modify the existing values using [↑][↓] buttons. Press [ENT] button to move to the next setting. 3.5.6.4. Time Display Setting Default Setting: ‘2.05:00 PM’ This option is how to display the current time of the terminal.
AC-2100 Plus 사용자 가이드 54 3.5.7.1. RS485 Set This option is to set RS485 ID in order to work together with RS485 device. Press [↑][↓] buttons to select the ID value, and press [ENT] button. Default Setting: ‘0’ After selecting the set value, press [ENT] button, and the screen will go to the upper menu. 3.6. Terminal Information Inquiry Select [3.Information] on the main menu, and the following screen will appear. All the environmental settings of the terminal can be checked in order.
AC-2100 Plus 사용자 가이드 Version WorkMode Language Auth Mode 1:1 Level 1:n Level Terminal Id Net Type Terminal IP Gateway Subnet Mask Server Type Server IP Server Port MAC Addr Card Ver Card Format All User All Admin Max User All FP Max FP All Log Max Log Serial Num 55 Terminal firmware version Terminal operating modes (T&A + security/T&A/food service) Language setting Authentication priority Authentication level applied when 1:1 authentication Authentication level applied when 1:n authentication Terminal ID
AC-2100 Plus 사용자 가이드 56 3.7.1. Terminal Lock Setting Select [F3~]→[5.Ext Function]→[1.Lock Term] on the main screen, and the following screen will appear. Default Setting: ‘2’ (Unlock Terminal) This function allows the administrator to directly lock or unlock the terminal without the server program. If it is set to ‘1’, nobody can access the office until the administrator releases the set. After selecting the set value, press [ENT] button, and the screen will go to the upper menu. 3.7.2.
AC-2100 Plus 사용자 가이드 57 3.7.3. Monitor Input Port Setting This option acts to connect the sensor to the terminal input port, and send a notice message to the server when the status is changed. Select [F3~]→[5.Ext Function]→[3.Monitor] on the main screen, and the following screen will appear. (Caution) DM2 is a currently unused spare port. Before using the relevant function, check the required ports and install. 3.7.3.1. Monitor 1 Input Port Setting Set when connecting an external contact to DM0.
AC-2100 Plus 사용자 가이드 - 58 ‘3.Fire NO’ or ‘4.Fire NC’: When the fire detection sensor is connected ‘5.Panic NO’ or ‘6.Panic NC’: When the panic situation detection sensor is connected ‘7.EMC NO’ or ‘8.EMC NC’: When the emergency detection sensor is connected ‘9.Ctrler Out’: When the authentication result is sent to the external controller (Connect the REDled of controller to DM0 or DM1 through the board has the TR. Set the relevant pin to ‘9.Ctrler Out’. WiegandOut must be set.
AC-2100 Plus 사용자 가이드 59 3.8. Device Setting Select [6.Device] on the main menu, and the following screen will appear. Press [↑][↓] buttons to select the menu you want to change, and press [ENT] button. Most of device settings are the option that does not need to change after installation. It is recommended that they are not changed unless there is any clear purpose. 3.8.1. System Configuration Select [F3~] → [6.Device] → [1. System Conf] on the main screen, and the following screen will appear. 3.8.1.1.
AC-2100 Plus 사용자 가이드 60 3.8.1.2. Language Setting Default Setting: ‘0.English’ If the language setting is changed, the voice message and the message on the LCD are changed into the set language. 3.8.2. Card Reader Format Setting Select [F3~] → [6.Device] → [2. Card Format] on the main screen, and the following screen will appear. Default Setting: ‘0.Default’ This option is to specify the format that displays the read card number. When setting to Hexa, the format is displayed to the hexadecimal number.
AC-2100 Plus 사용자 가이드 61 3.8.3.1. 1:1 Level Setting Default Setting: ‘4’ This option is to set the match degree with the same fingerprint when comparing the fingerprint on the fingerprint input window with the user fingerprint saved in the database. The higher authentication level may ensure the higher security. But it requires the relatively high concordance rate. When authenticating User ID, it high likely to deny authentication.
AC-2100 Plus 사용자 가이드 62 3.8.3.3. LFD Setting Default Setting: ‘1.None’ This option is to set the LFD level that can prevent fake fingerprints from entering. The higher LFD level may ensure the higher function that prevents the input of fake fingerprints made of rubber, paper, film, and silicon. However, too dry fingerprints may not be entered even when entering actual fingerprints. After selecting the set value, press [ENT] button, and the screen will go to the upper menu. 3.8.3.4.
AC-2100 Plus 사용자 가이드 63 Default Setting: ‘1’ This option is used only when the terminal is equipped with a separate controller operated by Wiegand input. After authentication, the following types of data are sent to the Wiegand port of the terminal. 1.None General case. The Wiegand Out port is not used. 2.26bit “Sitecode [1 byte] + User ID [2 bytes]” are transferred. User ID should be set to the 4-digit or less number. Example) SiteCode:045, UID:6543 → 1 00101101 0001 1001 10001111 0 3.
AC-2100 Plus 사용자 가이드 64 Default Setting: ‘2.No’ This option is available when the Wiegand card reader is used. When the mode is set to [1], the card information entering to ‘Wiegand In’ is bypassed to ‘Wiegand Out’. 3.8.5. Terminal Initialization Select [F3~] → [6.Device] → [5.Initialize] on the main screen, and the following screen will appear. Select [1] to initialize the set value; [2] to initialize the authentication records; [3] to initialize the factory; and [4] to use the UDL10 to backup the DB.
AC-2100 Plus 사용자 가이드 65 3.8.5.2. Authentication Records Initialization Select [1] to initialize, and [2] to cancel. This option deletes all authentication related logs except for set values and users. When initialization is successfully completed, the “Ppiririck” beep occurs and the screen moves to the upper menu. 3.8.5.3. Factory Initialization Select [1] to initialize, and [2] to cancel.
AC-2100 Plus 사용자 가이드 66 DB Backup Menu. Export Log - Used when the log data saved in the AC2100 terminal is exported to USB. - Data is saved with a file name of LOG.DAT in the place of “USB top-level folder → AC2100 folder → 00000000 (8-digit terminal ID) folder → LOG folder”. - Only log data can be saved, except for photos. Export User - Used when the user data saved in the AC2100 terminal is exported to USB. - Data is saved with a file name of USER.DAT in the unisuser folder.
AC-2100 Plus 사용자 가이드 67 Default Setting: ‘1.None’ This option is available when connecting the Slave Reader using the card or fingerprint to the terminal in order to use as a secondary authentication device. The mode is set to ‘2’ when connecting the Wiegand card reader, and ‘3’ when connecting the SR100. Press [ENT] button to move to the next setting. Default Setting: ‘2.No’ When setting to ‘1.Yes’, the Anti-Passback in the terminal is checked.
AC-2100 Plus 사용자 가이드 68 Press [ENT] button to move to the next setting. Default Setting: ‘1.None’ This screen is displayed only when is not set to ‘3’. When connecting an external device of LC010 to the terminal, the mode is set to ‘2.Lock Ctrl’. When the terminal interlocks with MCP040, RS485 ID must be set. UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro, Songpa-gu, Seoul, 05836, Republic of Korea TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.
AC-2100 Plus 사용자 가이드 69 4. How to Use Terminal 4.1. When operating to [1.Access] - Set to Menu → 3.Option → 1. Application → [1.Access]. 4.1.1. Authentication Mode - Press function keys, change to the desired authentication mode such as F1, F2, F3, F4, and then perform authentication. When perform authentication without pressing function keys specially, the mode is automatically authenticated to the access mode.
AC-2100 Plus 사용자 가이드 70 Place your finger on the fingerprint sensor, and the white light is on the fingerprint input window. Keep your finger until the white light is off with a beep sound. ▼ If your fingerprint is successfully authenticated, the voice message of “You are authorized” comes out and a success message is displayed on the LCD. ※Error Message: The following messages will appear with the voice message of “Place try again”.
AC-2100 Plus 사용자 가이드 71 Press [F2] key to change the authentication mode to Leave. ▼ If your fingerprint is successfully authenticated, the voice message of “You are authorized” comes out and a success message is displayed on the LCD. Error Message: The following messages will appear with the voice message of “Please try again”.
AC-2100 Plus 사용자 가이드 72 When the lamp is on the fingerprint input window with the voice message of “Please enter your fingerprint”, enter your fingerprint and keep your finger until the “beep” sound occurs. 4.2. When operating to [2.T&A] - Set to Menu → 3.Option → 1. Application → [2.T&A].
AC-2100 Plus 사용자 가이드 73 - When the mode is set to the food service control, the terminal is locked in the time other than meal times. The meal time must be set to more than one meal per person.
AC-2100 Plus 사용자 가이드 74 FCC Information This device complies with part 15 of the FCC Results. Operation is subject to the following two conditions : (1) This Device may not cause harmful interface, and (2) This device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for CLASS B digital device, pursuant to Part 15 of FCC Rules.