Report No.: 17PNS02071 03001 Safety Data Sheets Name of Goods: Polymer Li-ion Battery Commissioner: Dongguan Sunly Battery Technology Co., Ltd. Dongguan UTL Electronic Technology Co., Ltd.
Page 2 of 22 Report No.: 17PNS02071 03001 Safety Data Sheet (SDSs) Name of goods Polymer Li-ion Battery Mode 501220 Type 3.7V, 95mAh, 0.351Wh Commissioned by Commissioner address Manufacturer Manufacturer address Factory Dongguan Sunly Battery Technology Co., Ltd Building 30th, Arising Sun Industrial Area, No.8 Xinyang Road, Lin Village, Tangxia Town, Dongguan City Dongguan Sunly Battery Technology Co., Ltd Building 30th, Arising Sun Industrial Area, No.
Page 3 of 22 Report No.: 17PNS02071 03001 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING Product Identifier Product name: Polymer Li-ion Battery Model: 501220 3.7V, 95mAh, 0.351Wh Other means of identification Synonyms: None Recommended use of the chemical and restrictions on use Recommended Use: LITHIUM ION BATTERIES Uses advised against: No information available Details of the supplier of the safety data sheet Supplier Name Dongguan Sunly Battery Technology Co.
Page 4 of 22 Report No.: 17PNS02071 03001 GHS Label elements, including precautionary statements Emergency Overview Signal word Danger Hazard Statements Causes severe skin burns and eye damage May cause an allergic skin reaction May cause cancer Causes damage to organs through prolonged or repeated exposure This product is an article which contains a chemical substance. Safety information is given for exposure to the article as sold.
Page 5 of 22 Report No.: 17PNS02071 03001 Inhalation IF INHALED: Remove victim to fresh air and keep at rest in position comfortable for breathing Immediately call a POISON CENTER or doctor/physician Ingestion IF SEALLOWED: Rinse mouth.
Page 6 of 22 Report No.: 17PNS02071 03001 3. COMPOSITION/INFORMATION ON INGREDIENTS Common Chemical Name Chemical Formula Concentration (%) CAS Number LiCoO2 40.5 12190-79-3 (C2H2F2)n 0.8 24937-79-9 Al 5.7 7429-90-5 C24X12 20.1 7782-42-5 Styrene-butadiene rubber (C8H8.C4H6)x 1.1 61789-96-6 Carboxymethyl cellulose -- 0.3 9004-32-4 Copper Cu 10.4 7440-50-8 Nickel Ni 1.0 7440-02-0 LiPF6 20.
Page 7 of 22 Report No.: 17PNS02071 03001 edema may occur. Get medical attention immediately if symptoms occrur. Ingestion Do NOT induce vomiting. Rinse mouth immediately and drink plenty of water. Never give anything by mouth to an unconscious person. Call a physician or poison control center immediately. Self-protection of the first alder Ensure that medical personnel are aware of the material(s) involved, take precautions to protect themselves and prevent spread of contamination.
Page 8 of 22 Report No.: 17PNS02071 03001 Explosion Data Sensitivity to Mechanical Impact None. Sensitivity to Static Discharge None. Protective Equipment and Precautions for Firefighters As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear. 6. ACCIDENTAL RELEASE MEASURES Personal precautions, protective equipment and emergency procedures Personal Precautions Attention! Corrosive material.
Page 9 of 22 Report No.: 17PNS02071 03001 adequate ventilation and in closed systems. Do not eat, drink or smoke when using this product. Take off contaminated clothing and wash before reuse. Conditions for safe storage, including any incompatibilitie Storage Keep containers tightly closed in a dry, cool and well-ventilated place. Protect from moisture. Store locked up. Keep out of the reach of children. Store away from other materials. Incompatible Products. Acids. Bases. Oxidizing agent. 8.
Page 10 of 22 Aluminum 7429-90-5 Report No.: 17PNS02071 03001 TWA: 1 mg/m3 respirable fraction TWA: 15 mg/m3 total dust TWA: 5 mg/m3 respirable fraction (vacated)TWA: 15 mg/m3 total dust TWA: 10 mg/m3 total dust TWA: 5 mg/m3 respirable dust (vacated)TWA:5 mg/m3 respirable fraction(vacated) TWA: 5 mg/m3 Al Aluminum Nickel TWA: 1.5 mg/m3 7440-02-0 TWA: 1 mg/m3 IDLH: 10 mg/m3 (vacated)TWA: 1 mg/m3 TWA: 0.
Page 11 of 22 Report No.: 17PNS02071 03001 9.
Page 12 of 22 Softening Point No data available VOC Content (%) No data available Particle Size No data available Report No.: 17PNS02071 03001 Particle Size Distribution 10. STABILITY AND REACTIVITY Reactivity No data available. Chemical stability Stable under recommended storage and handling conditions. Possibility of Hazardous Reactions None under normal processing. Conditions to avoid Exposure to air or moisture over prolonged periods. Incompatible materials Acids. Bases. Oxidizing agent.
Page 13 of 22 Eye contact Report No.: 17PNS02071 03001 Specific test data for the substance or mixture is not available. Cause burns. (based on components). Corrosive to the eyes and may cause severe damage including blindness. Cause serious eye damage. May cause irreversible damage to eyes. Skin contact Specific test data for the substance or mixture is not available. Corrosive. (based on components). Cause burns. Ingestion Specific test data for the substance or mixture is not available.
Page 14 of 22 Lithium Cobalt Oxide Report No.
Page 15 of 22 Report No.: 17PNS02071 03001 Numerical measures of toxicity Product Information The following values are calculated based on chapter 3.1 of the GHS document ATEmix (oral) 4,000.00 mg/kg ATEmix (dermal) 2,400.00 mg/kg (ATE) 12. Ecological information Ecotoxicity Very toxic to aquatic life with long lasting effects.
Page 16 of 22 Nickel 7440-02-0 72h EC50:=0.18mg/L (Pseudokirchneriella subcapitata) 96h EC50:0.174-0.311 mg/L(Pseudokirchneriella subcapitata) Report No.: 17PNS02071 03001 48h EC50:>100 mg/L 48h EC50:=1 mg/L 96h LC50:>100mg/L (brachydanio rerio) 96h LC50:=1.3mg/L(Cyp rinus carpio) 96h LC50:=10.4 mg/L (Cyprinus carpio) Persistence and degradability No information available. Bioaccumulation No information available. Other adverse effects No information available. 13.
Page 17 of 22 Report No.: 17PNS02071 03001 14. TRANSPORT INFORMATION Note: The transportation of primary lithium cells and batteries is regulated by the international Civil Aviation Organization, International Air Transport Association, International Maritime Dangerous Goods Code and the US Department of Transportation. The batteries must meet the following criteria for shipment:1.
Page 18 of 22 RID Not regulated ADR Not regulated ADN Not regulated Report No.: 17PNS02071 03001 15. REGULATORY INFORMATION International Inventories TSCA Complies DSL All components are listed either on the DSL or NDSL TSCA – United States Toxic Substance Control Act Section 8(b) Inventory DSL/NDSL – Canadian Domestic Substance List/Non-Domestic Substances List US Federal Regulations SARA 313 Section 313 of Title III of the Superfund Amendments and Reauthorization Act of 1986(SARA).
Page 19 of 22 Report No.: 17PNS02071 03001 CWA (Clean Water Act) This product contains the following substance which are regulated pollutants pursuant to the Clean Water Act (40 CFR 122.21 and 40 CFR 122.
Page 20 of 22 Report No.: 17PNS02071 03001 1333-86-4 Copper X X X X X X X X X X X X X 7440-50-8 Aluminum 7429-90-5 Nickel X 7440-02-0 International Regulations Mexico National occupational exposure limits Component Carbon black 1333-86-4(10-30) Carcinogen Status Exposure Limits Mexico: TWA 3.5 mg/m3 Mexico: STEL 7 mg/m3 Mexico: TWA =1 mg/m3 Mexico: TWA =0.
Page 21 of 22 Revision Date 15-April -2016 Revision Note No information available Report No.: 17PNS02071 03001 Disclaimer The information provided in this Safety Data Sheet is correct to the best of our knowledge, information and belief at the date of its publication. The information given is designed only as a guidance for safe handling, use, processing, storage, transportation, disposal and release and is not to be considered a warranty or quality specification.
Page 22 of 22 Report No.: 17PNS02071 03001 Photos Fig.1 Overall view I of battery Fig.2 Overall view II of battery Dongguan UTL Electronic Technology Co., Ltd. 1F, Hengzheng Bldg, North Road of Station, Nancheng District, Dongguan, Guangdong, China Tel:+86-769-3893 3228 Fax:+86-769-3893 3229 E-mail: sales@gdutl.