Safety Data Sheet Version: V1.3 According to 2012 OSHA Hazard Communication Standard (29 CFR 1910.1200) REPORT NO.: LCS190515049ASD * The SDS is prepared based on the information provided by client. The contents and formats of this SDS are revised as per client's request. Section 1- Identification (a) Product identifier Lithium ion battery Product name (b) Other means of identification Model: CXY 503040 Nominal Voltage: 3.7V Nominal capacity: 300mAh Watt-hour: 1.11Wh Weight: 14.
Safety Data Sheet Version: V1.3 According to 2012 OSHA Hazard Communication Standard (29 CFR 1910.1200) REPORT NO.: LCS190515049ASD Emergency Overview Signal word Danger Hazard Statements: Toxic if swallowed. Harmful if inhaled. Causes severe skin burns and eye damage. Cause damage to organs through prolonged or repeated exposure.
Safety Data Sheet Version: V1.3 According to 2012 OSHA Hazard Communication Standard (29 CFR 1910.1200) REPORT NO.: LCS190515049ASD 32% of the mixture consists of ingredient(s) of unknown toxicity (e) Other information Very toxic to aquatic life with long lasting effects (f) Interactions with Other Chemicals No information available. Section 3- Composition/information on ingredients Chemical Name CAS Number Weight (%) Trade Secret Lithium manganate(Mn2LiO4) 12057-17-9 38.9 * Copper 7440-50-8 6.
Safety Data Sheet Version: V1.3 According to 2012 OSHA Hazard Communication Standard (29 CFR 1910.1200) REPORT NO.: LCS190515049ASD (a) Personal precautions, protective equipment and emergency procedures If the battery is released, remove personnel from area until fumes dissipate. Provide maximum ventilation to clear out hazardous gases. The preferred response is to leave the area and allow the vapors to dissipate. Avoid skin and eyes contact or inhalation of vapors.
Safety Data Sheet Version: V1.3 According to 2012 OSHA Hazard Communication Standard (29 CFR 1910.1200) REPORT NO.: LCS190515049ASD dust,fume,mist TWA:0.
Safety Data Sheet Version: V1.3 According to 2012 OSHA Hazard Communication Standard (29 CFR 1910.1200) REPORT NO.
Safety Data Sheet Version: V1.3 According to 2012 OSHA Hazard Communication Standard (29 CFR 1910.1200) REPORT NO.: LCS190515049ASD Specific test data for the substance or mixture is not available. Causes burns. (based on components). Ingestion causes burns of the upper digestive and respiratory tracts. May cause severe burning pain in the mouth and stomach with vomiting and diarrhea of dark blood. Blood pressure may decrease. Brownish or yellowish stains may be seen around the mouth.
Safety Data Sheet Version: V1.3 According to 2012 OSHA Hazard Communication Standard (29 CFR 1910.1200) REPORT NO.: LCS190515049ASD Aspiration Hazard No information available. Numerical measures of toxicity Product Information The following values are calculated based on chapter 3.1 of the GHS document ATEmix (oral): 12,905.00 mg/kg ATEmix (dermal): 10,200.
Safety Data Sheet Version: V1.3 According to 2012 OSHA Hazard Communication Standard (29 CFR 1910.1200) REPORT NO.: LCS190515049ASD Disposal should be in accordance with applicable regional, national and Contaminated Packaging local laws and regulations. California Hazardous Waste Codes 141 This product contains one or more substances that are listed with the State of California as a hazardous waste.
Safety Data Sheet Version: V1.3 According to 2012 OSHA Hazard Communication Standard (29 CFR 1910.1200) REPORT NO.: LCS190515049ASD Section 15- Regulatory information (a) International Inventories TSCA Complies. DSL All components are listed either on the DSL or NDSL. (b) US Federal Regulations SARA 313 Chemical Name Section 313 of Title III of the Superfund Amendments and Reauthorization Act of 1986 (SARA).
Safety Data Sheet Version: V1.3 According to 2012 OSHA Hazard Communication Standard (29 CFR 1910.1200) REPORT NO.: LCS190515049ASD 7440-50-8 (d) International Regulations Mexico National occupational exposure limits Component Graphite 7782-42-5 ( 15 - 40 ) Aluminum 7429-90-5 ( 7 - 13 ) Carcinogen Status Exposure Limits Mexico: TWA=3.5 mg/m 3 Mexico: TWA= 10 mg/m 3 3 Mexico: TWA= 1 mg/m 3 Mexico: TWA= 0.