User's Manual

Preliminary
ULTRA MAX PHASING TOOL 8000-2579-49 REV. B
USER GUIDE
1 of 9
8000-2579-49
Ultra Max
®
Phasing Tool
User Guide
AMX-1000
If you need assistance...
Contact your Technical Support.
About this guide
This guide provides you with information on how to
use the Phasing Tool. This tool eliminates the need
to use an oscilloscope when wirelessly phasing
and synchronizing systems.
About the product
Part numbers
Table 1. AMX-1000 Phasing tool kit with case
Item Qty Part Number
Phasing Tool 2 0304-0152-01
Brackets for Sense Coil 2 0400-1182-01
Sense Coils 2 0300-2274-01
Cable RG58A 12ft 1 6003-0313-01
Cable USB A/Micro B 6ft 1 6003-0148-01
A
ntenna 2.4GHz 2 3411-0024-01
Spare parts
A complete parts list is available online at:
http://www.sensormatic.com/support/techsupport/.
Login, and then click the Part Information link on
the Tech Support home page.
Part Number /
Product Code Description
9U*
FRU**
0352-0706-01 3dB Transceiver Antenna No Yes
0352-0707-01 Pickup Coil and Bracket No Yes
0352-0708-01 Phasing Tool Transceiver
Module
No Yes*
* Repairable unit
** Field replaceable unit.
*** Outside North America only.
Key features
Two identical phase modules are used. One is set
as a transmitter and the other is set as a receiver.
Both the receiver and transmitter are battery
operated. When the unit is connected to the laptop
via USB cable it switches to USB power.
The sense coils pick up a 58kHz signal from the
antenna. An application on the laptop shows the
phase delta between the systems. No oscilloscope
is required to complete phasing.
© 2016 Sensormatic Electronics, LLC