CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT Turbo Air Speed up the Pace of Innovation Glass Door Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment! FEATURE CHART TGM-14RV FLUORESCENT LAMP ADVERTISING PANEL EVAPORATOR FAN EVAPORATOR HINGE*TOP INDUCTION HOLE OF COLD AIR EXIT HOLE OF COLD AIR SHELF HANDLE FLUORESCENT LAMP (25W) HINGE*UNDER DOOR BOTTOM ASSEMBLY GRILL ADJUSTABLE FOOT CONDEN
HOW TO INSTALL In good ventilation. • Place the refrigerator in good ventilation for a good operation. Place the refrigerator on hard and level floor. • Unlevel floor may cause the refrigerator to make noise. Put away heat source from the refrigerator. • High ambient temperature will make cooling efficiency lower. Install the refrigerator at indoor not to get wet from the rain. • This unit is designed for indoor usage only. Avoid places that are exposed to smoke.
INSTALLATION OF CASTOR AND CASTOR BRAKE 1) Screw the castor (in rear side) and the castor brakes (in front side) by using castor wrench. 2) Use the castor shims to level the cabinet, if necessary, by inserting them to stems of the castors.
CLEANING Cleaning the interior and exterior • Wash with warm soapy water and rinse with wet cloth. • Wipe with dry cloth. • Clean gasket frequently. • Wash shelves with water. • If unit has dew drops on exterior, wipe away with dry cloth. This tends to happen in the rainy season. Check points after cleaning • Check again the refrigerator for safety. • Do not plug the power cord with wet hands. • Check for noise or unit not getting cold. Compressor Caution • Unplug the power cord before cleaning.
CAUTION Ventilation - Place the unit in a well ventilated area. - Keep the cabinet 4” from rear wall. Warning - Warranty will be voided if the following is found. • Low voltage to unit. Should be 115V/60Hz. • Power cord should not be more than 7 feet long from plug in connection to compressor. • Multiple units plugged into same circuit. • On extension cord. Start-up Temperature control - To keep the temperature down : Turn the dial by CLOCK-WISE.
BEFORE REQUSTING SERVICE SYMPTOMS Product freezing CAUSES SOLUTIONS • Only a small amount of product stored in unit. • Turn temperature control to normal. • Product on top shelf only freezing. • Rearrange product, due to close to fan. • Temperature of refrigerator below 35˚F. • Turn temperature control to normal. Not working - compressor and light not on • Power or electrical failure. • Check power by plugging power cord into another outlet that has power. Refrigerator not cooling well.
HOW TO ADJUST A SHELF POSITION AND REPLACE A LAMP 7
MANUFACTURING COMPANY TWO YEAR WARRANTY Turbo air warrants to the original purchaser of every new Turbo air refrigerated unit, the cabinet and all parts thereof, to be free from defects in material or workmanship, under normal use and service, for a period of two (2) year from the date of original installation or 27 months after shipment date from Turbo air , whichever occurs first.
What is NOT covered by this warranty Turbo airʼs sole obligation under this warranty is limited to either repair or replacement of parts, subject to the additional limitations below. This warranty neither assumes nor authorizes any person to assume obligations other than expressly covered by this warranty. 1. WARRANTY IS NOT TRANSFERABLE. This warranty is not assignable and applies only in favor of the original purchaser/user to whom delivered.
Warranty Claims... All claims for parts or labor must be made directly thorough Turbo Air. All claims should include: model number of the unit, the serial number of the cabinet, proof of purchase, date of installation, and all pertinent information supporting the alleged defect. In case of compressor replacement under warranty, either compressor or compressor tag must be returned to Turbo Air along with above listed information. Failure to comply with warranty policies will result in voiding claims.