Installation manual Track&Trace Edition 2020-06-01 TRUMPF Werkzeugmaschinen GmbH + Co. KG, Technische Redaktion Johann-Maus-Straße 2, D-71254 Ditzingen Fon: +49 7156 303 - 0 Internet: http://www.trumpf.com E-Mail: docu.th@de.trumpf.
Table of contents C1105en 2020-06-01 1 Components included 2 2 Customer checklist for installation preparation 6 3 Preparing the hall plan 7 4 Installation of the system 8 4.1 Mounting satellites 8 4.
1. Components included There are different package sizes. The number of satellites and markers differs depending on the package size. Track&Trace components Fig. 94174 Satellite 1 TRUMPF logo (also used as a reference point during calibration) 2 LED status ring Satellite 2 Components included Fig.
1 USB-C connection (power supply) 2 Ethernet port (power supply and data transmission) Connecting the satellite Fig. 94278 Marker 1 LED status ring 2 E-Ink display 3 TRUMPF logo Marker Fig. 94175 The marker is charged by induction.
Fastening set for markers 1 Fastening clip Fastening set for markers Fig.
Preinstalled industrial PC 1 2 Connection to customer's network 3 Start-up of the service port 4 Power supply Satellite network connection Preinstalled industrial PC C1105en 2020-06-01 Fig.
2. Customer checklist for installation preparation No. Designation Number Remark 1 Track&Trace components 1 Contents: satellites, operator's manual, markers, industrial PC, holders 2 Current hall plan / layout min. 1 Hall plan as background for the user interface (see "Preparing the hall plan", pg. 7) 3 Fastening material (screws, dowels, cable ties, etc.
3. Preparing the hall plan An up-to-date and suitable hall plan must be available at the commissioning date. A walk-through inspection of the hall is necessary in order to take into consideration the on-site conditions. The hall plan used also serves as a basic map for the localization in the user interface, and must meet certain requirements. Errors in the plan can lead to deviations in the marker position in the user interface.
4. Installation of the system 4.1 Mounting satellites The mounting position of the satellites is made available on a case-by-case basis by TRUMPF. Instructions for assembly The distance to cable bundles, cable racks and other electrical interference sources must be at least 1 m. Ideally directly on the wall, otherwise the distance to the wall must be < 5 cm or > 1 m. Interference (echo) occurs depending on the distance to the wall. The satellite must be located either very close to the wall or (e.g.
■ ■ ■ https://www.trumpf.com/en_US/products/software/softwareproducts/tracktrace/ Suitable screws and dowels Hammer drill or standard drill Safe ladder or boom lift Fasten satellite 1 Drilled holes Example Fig. 94277 1. Fasten holders to drilled holes in the wall, and fasten the satellite in the holder. 2. Or Fasten the satellite with a magnet. Then an arrester loop must be attached. For safety reasons, however, it is recommended for a permanent fastening with screws to be used. 3.
Integrate the satellite into the infrastructure 1 USB-C connection (power supply) 2 Ethernet port (power supply and data transmission) Connecting the satellite Fig. 94278 4. Connect satellite via POE (RJ45) to the power supply and the network with the preinstalled industrial PC. An amplifier must be used if the cable is 100 m long or more. The light ring of the satellite must respond. or Ø In exceptional cases after consultation with TRUMPF: Connect satellite via USB-C with the power supply.
− − ■ ■ trumpf.jfrog.io:8081 (TCP) gitlab.com/TRUMPF-corp/locationTrackingSytem/Development:443 (TCP) − 185.82.160.50 or tpp-de.tnt.api.trumpf.com − 185.82.163.20 or tpp-sg.tnt.api.trumpf.com − 218.4.161.131 or tpp-cn.tnt.api.trumpf.com − The ports 500 (UDP), 4500 (UDP) and 443 (TCP) − tnt-devops-puppet-server-xe5nibbltusunrkr.eu-central-1.opsworks-cm.io − The ports 8140, 8142 and 61613 (all TCP) DNS (port 53, TCP and UDP) and NTP (port 123, UDP) must function.
■ ■ (2) LAN3 For connection to the satellite network. (3) LAN1 and LAN2 Service or debugging ports for local error identification. If the local network connection of the preinstalled industrial PC is lost, a PC or laptop can be connected to the network via this connection (subnet 172.30.0.0, DHCP must be activated on the device). Address 172.30.0.1 in the browser provides access to the Setup/Network wizard for troubleshooting connection problems. 1.