Operator's manual Track&Trace
Operator's manual Track&Trace Original operator's manual Edition 2020-10-01
Order Information Please specify when ordering this document: Operator's manual Track&Trace Edition 2020-10-01 Document number B1105en Address for orders TRUMPF GmbH + Co. KG Technische Redaktion Johann-Maus-Straße 2 D-71254 Ditzingen Fon: +49 7156 303 - 0 Internet: http://www.trumpf.com E-Mail: docu.th@de.trumpf.com © TRUMPF GmbH + Co.
Table of contents 1 Safety 2 1.1 Overview of residual risks 2 FCC - safety and compliance B1105en 2020-10-01 2 1.2 Intended use 4 1.3 Frequencies and transmitting power 4 1.4 Climatic requirements 5 1.5 Disassembly and disposal 5 1.6 Data management 5 2 Technical Data 7 3 Operation 9 3.1 Settings 9 Start screen with dashboard 10 User management 10 3.2 Meaning of the LED lamps 10 3.
Residual risk 1. Safety 1.1 Overview of residual risks Hazard area Type of danger Measure to be taken by the user Satellite Risk of injury Cordon off the work area below the assembly area. Mechanical hazard Bruises or knocks due to falling satellites Use the enclosed brackets or own-construction brackets according to the Operator's manual. Use the screw locks. Bruises, knocks due to falling charging station Charging station Secure the charging station to the wall or table using screws/ bolts.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: ■ ■ ■ ■ Reorient or relocate the receiving antenna, Increase the separation between the equipment and receiver, Connect the equipment into an outlet on a circuit different from that to which the receiver is connected, Consult the dealer or an experienced radio/TV technician
1.2 Track&Trace Intended use The system is designed for localization during sheet metal processing. The user is allowed to monitor the location of production orders, load carriers, vehicles and tools with the system. Installation, operating and transport conditions defined by TRUMPF must be adhered to and maintenance work must be carried out in accordance with the Operator's manual.
ZigBee: 2.4 GHz - 2.48 GHz Max power (EIRP) 4 dBm 1.4 Climatic requirements Operating temperature of the system 0 °C (+32 °F) to +45 °C (+113 °F) Loading operation temperature marker 0 °C (+32 °F) to +39 °C (+102 °F) Relative humidity max. 100 % at +24 °C (+75 °F) Ambient conditions 1.5 Tab. 2 Disassembly and disposal TRUMPF recommends commissioning Technical Service or a specialist disposal company with the dismantling and disposal of a machine, component or system.
Data type Brief description & examples Operating status Data concerning system configuration and system status (device status, location status, faults). Diagnostics data Message data (e.g. malfunction files). Environmental data The air pressure in the satellite and marker is measured and used to better determine the height of the marker. System usage behavior Data such as access to the Track&Trace user interface or operation of the interface allow conclusions to be drawn for optimizing production.
2. Marker Technical Data Housing material ABS/PC, PC, TPU Weight 160 g Load 8 hours (100%) with supplied charging station Temperature -10°C +39°C Radio UWB: 3.25 GHz - 4.75 GHz Max Mean power (EIRP) -41.3 dBm/Mhz BLE: 2.4 GHz - 2.48 GHz Max power (EIRP) 4 dBm ZigBee (sensor network IEEE 802.15.4): 2.4 GHz 2.48 GHz Max power (EIRP) 4 dBm E-Ink display 2.
Temperature 0°C - +45°C Radio UWB: 3.25 GHz - 4.75 GHz Max Mean power (EIRP) -41.3 dBm/Mhz BLE: 2.4 GHz - 2.48 GHz Max power (EIRP) 4 dBm ZigBee (sensor network IEEE 802.15.4): 2.4 GHz 2.48 GHz Max power (EIRP) 4 dBm LED RGB-LED ring for diagnostics Mounting Supplied fastening kit Certification CE Geometry Tab.
3. 1 Dialog for linking markers 2 Search box for filtering the markers 3 4 Operation Marker position in the production overview 5 Diagnostic list 6 Zooming view in/out Changing the user role User interface Fig. 101300 More information at: www.trumpf.com 3.1 Settings Various settings may be modified. Firstly there are general settings, then there are other options for the hall plan view.
Start screen with dashboard The start screen shows a dashboard with various functions. Fig. 96602 User management There are two user roles, operator and administrator. ■ ■ Operators can manage markers and orders. Administrators can also set up satellites and modify the setup using the hall plan. 3.
Explanation Color / behavior Satellite not connected Red (slow flashing) Satellite is dialing into the network Blue Satellite connected White (illuminated) LED satellite 3.3 Tab. 7 Live view of markers and orders In the live view, markers and orders can be found directly via the search. Fig. 98109 Filtering the markers Using the filter for markers, you can find certain markers. Press symbol on the hall plan to highlight the marker.
Displaying the marker details Fig. 98111 Ø In the hall plan, click on a marker to display the marker details. − Number of marker − Battery status − Connected or unconnected status Tip Click on the star to display the marker as a favorite regardless of a filter. 3.4 Switching on and resetting the marker 1. Pull the enclosed magnet over the TRUMPF logo in order to switch on the marker. The marker only has to be switched off in the event of malfunctions. 2.
Note Several markers can be assigned to different orders. 4. Select marker. ■ The marker is marked as connected. ■ 3.6 Once the order has been processed, the marker can be removed from the order again using the same dialog. Charging a marker The markers can be charged in the supplied charging station. Up to 10 markers can be charged. The charging station can be mounted on a base or suspended from above. It has a power connection and a switch for switching on and off.
2. When the markers are charged, remove the markers and switch off the charging station. 3.7 Diagnostics In the >diagnosis menu, messages on the battery status or regarding the connection between satellites and markers are listed. Example diagnostics 3.8 Fig. 96601 Accessories and software For service purposes, it is recommended for the TeamViewer program to be installed on the company computer that accesses the Track&Trace industrial PC.
4. Spare parts list Fig. 98116 Position Material-NO. Designation 10 2417477 Satellite 20 2417475 Marker 30 2417474 Adapter Tab.
16 Spare parts list 2020-10-01 B1105en