Specifications

RECYCLE RESPONSIBLY
6V
Gel
PHYSICAL SPECIFICATIONS
BCI MODEL NAME TERMINAL TYPE
E
DIMENSIONS
C
INCHES (mm) WEIGHT
F
LBS. (kg) INSTALLATION ORIENTATION
GC2 6V-GEL 7
LENGTH WIDTH HEIGHT
D
68 (31)
Horizontal
and Vertical
10.25 (260) 7.09 (180) 10.88 (276)
DATA SHEET
6 VOLT
MODEL 6V-Gel
VOLTAGE 6
CAPACITY 189Ah @ 20Hr
MATERIAL Polypropylene
BATTERY VRLA GEL / Non-Spillable / Maintenance-Free
COLOR Maroon (case) Grey (cover)
WATERING No Watering Required
ELECTRICAL SPECIFICATIONS
VOLTAGE CAPACITY
A
MINUTES CAPACITY
B
AMP-HOURS (Ah) ENERGY (kWh) INTERNAL RESISTANCE (mΩ) SHORT CIRCUIT CURRENT (amps)
6
@ 25 Amps 5-Hr 10-Hr 20-Hr 100-Hr 100-Hr
394 154 167 189 198 1.19
CHARGING TEMPERATURE COMPENSATION
ADD SUBTRACT
0.005 volt per cell for every 1°C below 25°C
0.0028 volt per cell for every 1°F below 7F
0.005 volt per cell for every 1°C above 25°C
0.0028 volt per cell for every 1°F above 7F
MOTIVE 6V-GEL
CHARGING INSTRUCTIONS
CHARGER VOLTAGE SETTINGS (AT 77°F/25°C)
SYSTEM VOLTAGE 6V 12V 24V 36V 48V
Maximum Charge Current (A) 13% of C
20
Absorption Voltage (2.40 V/cell) 7.20 14.40 28.80 43.20 57.60
Float Voltage (2.25 V/cell) 6.75 13.50 27.00 40.50 54.00
Do not install or charge batteries in a sealed or non-ventilated compartment. Constant under
or overcharging will damage the battery and shorten its life as with any battery.
STATE OF CHARGE MEASURE OF OPEN-CIRCUIT VOLTAGE
PERCENTAGE CHARGE CELL 6 VOLT
100 2.14 6.42
75 2.11 6.33
50 2.06 6.18
25 2.00 6.00
0 1.97 5.91
OPERATIONAL DATA
OPERATING TEMPERATURE SELF DISCHARGE
-4°F to 113°F (-20°C to +45°C). At
temperatures below 32°F (0°C) maintain a
state of charge greater than 60%.
Less than 3% per month depending
on storage temperature conditions

Summary of content (2 pages)