pr ch re R W a od an gis e uc ce te gi rr t— to r o st an ww w nlin ra ty w. in a e ti t tri o p p F R o da n lit EE y f : e .
B140-1P1-WP-1 B140-101X B140-1A1-WP B140-002 B140-004 B140-1A0 B140-1A0-WP-1 B140-1P0 B140-1P0-WP-1 B140-110 Local Unit (L), Remote Unit (R), or Both (B) External Power Supplies (0, 1, or 2) Mounting Hardware Wallplate Screws Screwdriver for Equalization Adjustment DVI Daisy-chain Cable B140-101 Package Contents B B B B L L R R R R R 0 0 1 2 1 1 1 1 0 0 1 X X X X X X X X X X X X X X X Product Features All • Support DVI-D Single-Link video resolutions up to 1920
Product Features B140-1P1-WP-1 • DVI over Cat5 Passive Extender Wallplate Kit • Extend a 1024 x 768 (60Hz) signal up to 75 ft. from the source, or a 1920 x 1080 (60Hz) signal up to 50 ft. from the source • RJ45-style wallplates allow for the use of standard Cat5e/6 patch cables; 110 punchdown connection not required • No external power required B140-101X • DVI over Cat5 Active Extender Kit (Box-style) • Extend a 1024 x 768 (60Hz) signal up to 200 ft.
Product Features B140-002 • 2-Port DVI over Cat5 Extender/Splitter Local Transmitter Unit (Box-style) • Splits a DVI-D Single-Link signal into 2 separate signals • Works with remote/repeater and receiver units to extend a DVI-D Single-Link signal passed the 16-ft. (5 m.
Product Features B140-1A0 • DVI over Cat5 Active Extender Remote Receiver Unit (Box-style) • Works with B140-002 and B140-004 extender/splitters to extend a 1024 x 768 (60Hz) signal up to 200 ft. from the source, or a 1920 x 1080 (60Hz) signal up to 150 ft.
Product Features B140-1P0-WP-1 • DVI over Cat5 Passive Extender Wallplate • Works with B140-002 and B140-004 extender/splitters to extend a 1024 x 768 (60Hz) signal up to 75 ft. from the source, or a 1920 x 1080 (60Hz) signal up to 50 ft. from the source • RJ45-style wallplate allows for the use of standard Cat5e/6 patch cables; 110 punchdown connection not required.
Product Features Optional Accessories: • B132-004-RB 1U Rackmount Bracket • N202-Series Cat6 24 AWG, solid wire patch cables • P561-Series DVI-D Single-Link cables 201110026-93-3094-EN.
Mounting (Optional) The B140-101X, B140-002, B140-004, B140-1A0 and B140-110 come with mounting hardware that allows them to be mounted in a variety of ways. The following images show the different ways the included mounting brackets can be attached for different mounting methods. Note: The B140-004 can also be mounted to a Tripp Lite B132-004-RB 1U Rackmount Bracket. Up to 3 B140-004 local units can be connected to a B132-004-RB. Wallmount 19” Rackmount 201110026-93-3094-EN.
Standard Extender Kit Installation (B140-101, B140-1P1-WP-1, B140-101X, B140-1A1-WP) Notes: 1. The diagram below shows a B140-101X installation. Installation will be the same for the B140-1A1-WP. Installation will be similar for the B140-101 and B140-1P1-WP-1, except that they will not require external power. 2. Test to make sure that the entire installation works properly before pulling cables through ceilings/walls. 3. To achieve maximum distance and performance, use 24 AWG Solid Wire Cat5e/6 cable.
Standard Extender Kit Installation 3 B140-1A1-WP only: Connect the external power supply to the local unit and plug it into a Trip Lite Surge Suppressor, Power Distribution Unit (PDU), or Uninterruptable Power Supply (UPS). The Green Power LED will illuminate. 4 Connect the RJ45 ports on the local and remote units using Cat5e/6 cable.
Extender Kit with Remote/Repeater Installation (B140-101X and B140-1A1-WP extender kits only) Notes: 1. Test to make sure the entire installation works properly before pulling cables through ceilings/walls. 2. To achieve maximum distance and performance, use 24 AWG solid wire Cat5e/6 cable. Using stranded wire Cat5e/6 cable, or cable with a gauge (AWG) size higher than 24 AWG, will result in shorter extension distance. All Tripp Lite N202-Series Cat6 cables are made with 24 AWG solid wire cabling. 3.
Extender Kit with Remote/Repeater Installation (B140-101X and B140-1A1-WP extender kits only) 4 Using Cat5e/6 cable, connect the RJ45 port on the local unit to the RJ45 INPUT port on the B140-110 remote/repeater unit. 5 Connect a monitor to the DVI OUTPUT port on the remote/repeater unit using a Tripp Lite P561-Series DVI-D Single-Link Cable. 6 Connect the external power supply to the remote/repeater unit and plug it into a Tripp Lite Surge Suppressor, PDU or UPS.
Extender Kit with Remote/Repeater Installation (B140-101X and B140-1A1-WP extender kits only) 11 Using Cat5e/6 cable, connect the RJ45 OUTPUT port on the last remote/repeater unit to the RJ45 INPUT port of the B140-101X or B140-1A1-WP remote receiver unit. 12 Connect a monitor to the DVI OUTPUT port on the remote receiver unit using a Tripp Lite P561-Series DVI-D Single-Link Cable. 13 Connect the external power supply to the remote receiver unit and plug it into a Tripp Lite Surge Suppressor, PDU or UPS.
Standard Extender/Splitter Installation Notes: 1. The diagram below shows a B140-004 installation. Installation will be the same when using a B140-002, except that the B140-002 has fewer RJ45 ports and no local monitor port. 2. Test to make sure that the entire installation works properly before pulling cables through ceilings/walls. 3. To achieve maximum distance and performance, use 24 AWG solid wire Cat5e/6 cable.
Standard Extender/Splitter Installation 1 Make sure the DVI source is powered OFF. 2 Connect the DVI source to the DVI port on the B140-002 or B140-004 labeled INPUT using a Tripp Lite P561-Series DVI-D Single-Link Cable. 3 Optional for B140-004: Connect a DVI monitor to the DVI port on the B140-004 marked LOCAL using a Tripp Lite P561-Series DVI-D Single-Link Cable. 4 Connect the external power supply to the B140-002 or B140-004 local unit and plug it into a Tripp Lite Surge Suppressor, PDU or UPS.
Standard Extender/Splitter Installation 9 Connect the B140-1P0 DVI-D Single-Link connector to the monitor; or, connect the B140-1P0-WP-1, B140-1A0 or B140-1A0-WP-1 to the monitor using a Tripp Lite P561-Series DVI-D Single-Link Cable. The Green RJ45 LED on the B140-1P0 and the Green LED on the B140-1P0-WP-1 illuminate to indicate the unit is receiving power from the monitor. 10 Repeat step 9 for each additional monitor you are connecting. 11 Turn on the power to the DVI source.
Extender/Splitter with Remote/Repeater Installation (B140-1A0 and B140-1A0-WP-1 remote receiver units only) Notes: 1. Test to make sure the entire installation works properly before pulling cables through ceilings/walls. 2. To achieve maximum distance and performance, use 24 AWG solid wire Cat5e/6 cable. Using stranded wire Cat5e/6 cable, or cable with a gauge (AWG) size higher than 24 AWG, will result in shorter extension distance.
Extender/Splitter with Remote/Repeater Installation (B140-1A0 and B140-1A0-WP-1 remote receiver units only) 2 Connect the DVI source to the INPUT port on the B140-002 or B140-004 using a Tripp Lite P561-Series DVI-D Single-Link Cable. 3 Optional for B140-004: Connect a local monitor to the DVI OUTPUT port using a Tripp Lite P561-Series DVI-D Single-Link Cable. 4 Connect the external power supply to the local unit and plug it into a Tripp Lite Surge Suppressor, PDU or UPS.
Extender/Splitter with Remote/Repeater Installation (B140-1A0 and B140-1A0-WP-1 remote receiver units only) 10 Connect the external power supply to the remote/repeater unit and plug it into a Tripp Lite Surge Suppressor, PDU or UPS. The Green Power LED and the Green RJ45 LEDs illuminate to indicate the unit is receiving power. 11 To add a third remote/repeater unit, repeat steps 8 through 10. To finish your installation with a B140-1A0 or B140-1A0-WP-1 remote receiver unit, proceed to step 12.
Extender/Splitter Daisy-Chain Installation (B140-004 only) Notes: 1. Test to make sure that the entire installation works properly before pulling cables through ceilings/walls. 2. To achieve maximum distance and performance, use 24 AWG solid wire Cat5e/6 cable. Using stranded wire cable, or cable with a gauge (AWG) size higher than 24 AWG, will result in lesser performance and shorter extension distance. Tripp Lite N202-Series (Cat6) patch cables are made with 24 AWG solid wire cabling.
Extender/Splitter Daisy-Chain Installation 1 Make sure the DVI source is powered OFF. 2 Connect the DVI source to the DVI port on the B140-004 labeled INPUT using a Tripp Lite P561-Series DVI-D Single-Link Cable. 3 Connect the external power supply to the B140-004 local unit and plug it into a Tripp Lite Surge Suppressor, PDU or UPS. The Green RJ45 LEDs and Red Power LED will illuminate to indicate power is being received from the external power supply.
Extender/Splitter Daisy-Chain Installation 12 Connect the B140-1P0 DVI-D Single-Link Connector to the monitor; or, connect the B140-1P0-WP-1, B140-1A0 or B140-1A0-WP-1 to the monitor using a Tripp Lite P561-Series DVI-D Single-Link Cable. The Green RJ45 LED on the B140-1P0 and the Green LED on the B140-1P0-WP-1 illuminate to indicate the unit is receiving power from the monitor. 13 Repeat step 12 for each additional monitor you are connecting. 14 Turn on the power to the DVI source.
Extender/Splitter Daisy-Chain with Remote/ Repeater Installation (B140-004 extender/splitter, and B140-1A0 and B140-1A0-WP remote receivers only) Up to 175 ft. at 1024 x 768 (60Hz) Up to 125 ft. at 1920 x 1080 (60Hz) Up to 175 ft. at 1024 x 768 (60Hz) Up to 125 ft.
Extender/Splitter Daisy-Chain with Remote/ Repeater Installation (B140-004 extender/splitter, and B140-1A0 and B140-1A0-WP remote receivers only) 1 Make sure the DVI source is powered OFF. 2 Connect the DVI source to the INPUT port on the B140-004 using a Tripp Lite P561-Series DVI-D Single-Link Cable. 3 Connect the LOCAL port on the B140-004 to the INPUT port on a second B140-004 using the included 1-ft. DVI daisy-chain cable. 4 Repeat step 3 if you want to connect a third B140-004.
Extender/Splitter Daisy-Chain with Remote/ Repeater Installation (B140-004 extender/splitter, and B140-1A0 and B140-1A0-WP remote receivers only) Up to 4 units can be daisy-chained (3 remote/repeaters and 1 receiver). To connect additional remote/repeater units, proceed to step 11. To finish your installation with a B140-1A0 or B140-1A0-WP-1 remote receiver unit, proceed to step 15.
Extender/Splitter Daisy-Chain with Remote/ Repeater Installation (B140-004 extender/splitter, and B140-1A0 and B140-1A0-WP remote receivers only) 18 Repeat steps 8 through 17 for each additional RJ45 output port on the local transmitter units. 19 Turn on the power to the DVI source. The Orange RJ45 LEDs on the local transmitter, remote/repeater and B140-1A0 illuminate to indicate a signal is being received from the source.
Warranty & Warranty Registration 1-Year Limited Warranty TRIPP LITE warrants its products to be free from defects in materials and workmanship for a period of one (1) year from the date of initial purchase. TRIPP LITE’s obligation under this warranty is limited to repairing or replacing (at its sole option) any such defective products. To obtain service under this warranty, you must obtain a Returned Material Authorization (RMA) number from TRIPP LITE or an authorized TRIPP LITE service center.
201110026-93-3094-EN.indd 28 1111 W. 35th Street, Chicago, IL 60609 USA www.tripplite.