Warning! This product includes moving parts. Keep your fingers or any other objects away. Warning! This product was designed to prevent water leakage damages and should be used for this purpose only. SHUTTIE SPECIFICATION Part No. HDW-000081-001 Product description The wireless, battery operated water Actuator is mounted on an ISO5211 ball valve installed on the main water line. The water supply automatically shuts off whenever a leak is detected. Shutoff can also be manually controlled by the user.
FCC STATEMENTS IC STATEMENTS This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s).
What’s Included 1 Shuttie 7 T-Shaped Key 2 Actuator Valve 8 Screws Perpendicular Actuator Mount 9 Lock washers 10 Nuts 11 Batteries 12 Shuttie Installation Manual 3 Perpendicular Valve Adapter Insert 4 5 In-line Actuator Mount 6 In-line Valve Adapter Insert 3 4 5 6 1 2 7 Installation manual Installation manual Guide d'installation Guide d'installation
11 8 12 9 10 What You Need 1 Phillips Head Screwdriver Installation manual Guide d'installation
What To Do First 1 2 Call a plumber Ask the plumber to install the valve because the water pipe will need to be cut.
Installation Options Shuttie can be installed either in-line or perpendicular to the water line.
Installing Shuttie Before you begin installing Shuttie, watch the video at alertlabs.com/ShuttieInstall. Remove Shuttie from the box and remove the plastic wrap from the batteries. NOTE: When the batteries are first installed and the compartment is closed, Shuttie will automatically start a cleaning process where it will close and then open again.
RED - Error BLUE - Communication fault GREEN - Operating OFF - No power 1 Inserting The Batteries Loosen the screw on the bottom of the battery compartment to remove the cap using a Phillips-head #1 screwdriver. Place all 4 x CR123 batteries into the compartment with ‘ - ’ end facing out. Place the cap back onto the compartment. Align the edges of the cap and compartment before tightening the screw to make sure it closes properly. Press the orange button briefly to check the Shuttie LED status color.
LONG ACTUATOR MOUNT In-line installation SHORT ACTUATOR MOUNT Perpendicular installation 2 Installing The Adapter Open a water tap briefly to confirm that the valve is open and water is running. If the valve is closed, turn it 90 degrees using a wrench. Select the actuator mount according to installation type. Remove the one you need from the box.
IN-LINE INSTALLATION PERPENDICULAR INSTALLATION 3 Place the valve adapter insert onto the valve. The direction of the rectangular slot will depend on the type of installation (see images above). PARALLEL to the pipe - In-line installation PERPENDICULAR to the pipe - Perpendicular installation.
4 Slide the gray actuator mount over the valve adapter insert, aligning the screw holes on the water valve. NOTE: There are 2 holes for screws on opposite corners of the actuator mount that align to the holes on the water valve.
5 Next you will need the bag of screws, lock washers, and nuts. Insert the screws through the mount and valve. Tighten the nuts with lock washers onto the screws. NOTE: Fully tighten the screws with the hexagon heads inside the cut-outs in the adapter mount.
Brass actuator shaft in open position 6 Mounting Shuttie Make sure Shuttie is set to the open position. When the line of the brass actuator shaft is horizontal, Shuttie is in the open position . The metal locking pin must also be pulled out so that Shuttie can slide onto the actuator mount.
7 Slide Shuttie onto the actuator mount by inserting the brass actuator shaft into the rectangular slot.
8 Make sure that you have access to the metal locking pin once Shuttie is attached. Push the metal locking pin into its slots to lock the valve adapter in place.
Brass actuator shaft in closed position 9 Now you can test that valve will close. Press and hold the orange button for 5 seconds then release. The line of the brass actuator shaft will move to a vertical position to match . Turn on a water tap to confirm that water flow through the pipe stops. Test that the valve will open. Press and hold the orange button again for 5 seconds then release. The line of the actuator shaft will move to the horizontal position to match .
Troubleshooting How do I know if the water valve is open? Open a water tap briefly to confirm that the valve is open and water is running. How do I open the water valve if it’s closed? If the valve is closed at the beginning of the installation process, turn the valve 90 degrees with a wrench. After the adapter is installed you can use the T-shaped key that comes in the Shuttie box.