Safe Connected Property Thank you for choosing the Triple+ CLM™ Cloud-based Leak Management system designed to detect water leaks and prevent the subsequent damages. Triple+ CLM™ system will give you peace of mind while at home and away. Triple+ CLM™ line of products is the most comprehensive leak management and damage prevention solution in the market. The battery operated system includeswireless water flood detectors, shutoff units and a HUB. Signal repeaters can be included if necessary.
The primary advantage of the Triple+ CLM™ lies in the simplicity and completeness of the solution. Having a wireless and battery operated system assures that the installation is handled in minutes without the need to trench cables or involvement of an electrician. The Triple+ CLM™ smartphone App offers a true remote management regardless of being home or away.
General Info Warnings This product was designed to prevent water leak damages and as such should be used for water piping only. Please read through the instructions carefully and follow the steps of the system’s installation. Please maintain this document in a safe place for future reference. When in any doubt, contact your authorized distributor or installer. Keep your fingers or other objects away from moving parts.
CLM TM System component pairing and positioning Triple+ CLM™ system is installed by a certified professional installer and activated using the mobile installer’s App. Please look for Triple+ CLM™ Installer App in Google Play for Android OS-based smartphones or in the App Store for iOS devices.
Triple+ CLMTM HUB Triple+ CLM™ HUB performs the functions of a system gateway. It is used to provide access to the Internet or a private computer network. It can function in a wired LAN (local area network), in a wireless-only LAN (WLAN), or in a mixed wired/wireless network, depending on the need. Once paired by the professional installer using the Triple+ CLM™ Installer’s App, the HUB is ready for action. The HUB allows understanding of devices’ state & Remote control of water shutoff units.
+ HUB description E D C A B F A_ Power cable. B_ Table mount bracket. C_ Lower cover. D_ HUB circuit body E_ RGB LED indicator.
+ HUB installation When interested in HUB wall mounting, please follow the following instructions: 1. Detach the HUB from the table stand as described below. 3. Connect the HUB to the AC/DC adaptor jack. Plug the LAN cable into the LAN inlet, if the HUB will be permanently operated via the LAN. External Adaptor Jack LAN Inlet 5. For table mounting, connect the table stand to the HUB and place it on the table. 10 2.
+ Expected HUB LED behavior 1. Faultless communication of the HUB with all the components and with the server : The HUB RGB LED will repeatedly blink in GREEN every 5 seconds. 2. Failure in communication with the server or with any of the system components: The HUB RGB LED will repeatedly blink in BLUE every 5 seconds. 3.
Flood Detector Setup The Triple+ CLM™ flood detectors are to be installed in places probe to water floods or leaks. When a puddle of water is detected, wireless signal is dispatched to initiate closure of the shutoff unit(s) and push notifications is sent to the End User’s App.
+ Flood Detector description 4 3 5 1 2 1_Indication LED 2_Water detector 3_Battery housing cover 4_Wall mount bracket 5_Double-sided adhesive tape application locations (rear) 13
+ Flood Detector installation 1. Open the battery housing cover by pulling it towards the cable, while holding the detector body. 4. Close the battery housing cover. 2. Remove the cover and expose the battery housing. 5. Apply the attached double-sided adhesive tape strips to the battery housing cover in the placed defined on the picture. 6. Choose the position and height from the floor level most suitable for installation, so during flooding detector’s only electrodes would get wet.
+ Expected Flood Detector LED behavior 1. GREEN blink once in 30 seconds – all is OK 2. RED blink once in 30 seconds – communication problems 3. RED blink once in 10 seconds – ongoing water leak 4. BLUE blink once in 30 seconds – low flood detector battery + Flood Detector installation limitations Places where the detector should not be installed or positioned at: Within a metal cabinet or anywhere that might influence wireless communications.
Integrated Shutoff Setup The Integrated ¾”-pipe diameter compatible Shutoff unit is installed on the main water supply pipe within the premises (or outdoors, in a water tight plastic casing) and controls the water flow within the pipeline. When needed, using standard plumbing adapters, the unit can interface various pipe diameters. 1. The system should not disconnect a fire extinguishing line or a fire sprinkler line. 2.
+ Integrated Shutoff unit description 1 2 3 4 5 6 7 1_Closing/ opening handle. 2_Close/ open dial. 3_Disconnection unit (valve) body. 4_Battery cover 5_Entry/ exit 3/4” adapter. 6_Base for non-wall mounted valve 7_Base for wall mounted valve.
+ Integrated Shutoff unit installation 1. Installation and/or replacement of a battery should be performed by authorized personnel. 2. The system should not disconnect a fire extinguishing line or a fire sprinkler line. 3. Locate the most suitable place for installation on the water line (as indicated above.) 4. Shut down the water supply, using the main valve of the building or site. 5. Dismantle the water line connectors in a way that would leave a gap suitable for installing the 3/4” valve. 6.
Triple+ CLM™ Actuator Shutoff Unit The wireless, battery operated water and gas Shutoff unit is installed on any ISO5211 valve. It will actuate whenever a risky event is identified or when manually requested by the user. This actuator is mounted on a ISO5211 flange using 2 screws, provided with the installation kit. It is IP68-rated, meaning that its enclosure is both dust and water tight and can also be submerged into water. The unit fits 1/2”, 3/4”, 1” and 1 1/4” pipe diameters.
+ Actuator Shutoff unit description D E C F B A G J H I K A_Shutoff unit motor B_Bottom part of the case C_Motor stem position windows D_Indication RGB LED E_Multipurpose button F_Top part of the case G_Screw tunnel H_Battery housing I_Mounting fitting J_Lock K_Battery housing cover* *Just in the version 2 of the Shutoff unit 21
+ Actuator Shutoff unit Warnings 1. The system should not disconnect a fire extinguishing line or a fire sprinkler line. 2. Ensure easy access shut off unit in case it might be required for service. 3. The unit can be installed perpendicularly or in parallel with the pipe. 4. With the utilization of the locking pin, a comfortable shutoff disconnection should be possible after installation. 5. Do not position shutoff units within metal cabinets. 6.
+ Shutoff unit setup and mounting 1. Locate the most suitable place for installation on the water line. 2. Shut down the water supply, using the main valve of the building or site. 3. Mount the neck assembly on the shutoff and install it on ISO5211 mounting pad using the attached screws, washers and nuts. Please note, that the long neck is necessary while mounting the shutoff in parallel with the water pipe and the short neck is required when the shutoff is mounted perpendicularly to the water pipe.
+ Actuator Shutoff unit alignment reset The shutoff unit alignment reset is necessary in order to indicate the CLM™ HUB that the unit is in the “CLOSED” position and thus prevents the water from passing through the pipe. 1. Regardless of the shutoff mounting, whether parallel or perpendicular to the water flow direction, align the slot on the top part of the shutoff motor stem perpendicularly to the water flow direction.
+ Expected Actuator Shutoff unit LED behavior In order to save the shutoff unit battery, the LED indicator is not active, unless the unit button is momentarily pressed. The activity time frame of the LED indicator is 30 seconds. 1. Faultless communication of the HUB with all the components and with the server: The SHUTOFF UNIT LED will repeatedly blink in GREEN every 5 seconds (see attached time diagram). 2.
FCC and Industry Canada Compliance Statement This device complies with FCC Rules Part 15 and with Industry Canada license-exempt RSS standard(s). Operation is subject to two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference that may be received or that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
FCC and Industry Canada Compliance Statement Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. Cet appareil numerique de la classe B est conforme a la norme NMB-003 du Canada.
Triple+ Ltd. | 5 Hamada St., High Tech Park, Yoqneam, 2069200, Israel +972-(0)72-2211370 | info@tripleplus.io | www.tripleplus.