0 13 11 12 6 5 4 R2out R1out T2in T1in C2- C2+ C1- C1+ nSHDN nEN note: Radio inputs are 5V tolerant, however 3V3 is recommended.
O Series Data Radio – User Manual Power Supply Filtering Page 16 © Copyright 2008 Trio DataCom Pty. Ltd.
O Series Data Radio – User Manual Part G – Mounting and LED Indicators Mounting & Connector Information Please Note : Mating connectors can be supplied with each radio or seperately. Please order as part number SM%CO2241-20X2 Page 17 © Copyright 2008 Trio DataCom Pty. Ltd.
O Series Data Radio – User Manual Antenna Port Cabling (Hazardous Installations) When the O Series OEM module is intended to be used in equipment which is compliant with Class I, Division 2 - Groups A,B,C,D Hazardous Locations, the antenna conenctors need to be retained using a soldered connection as shown in the diagrams below. The method of soldered retention will depend on the model of O Series OEM product in use. See below for model specific guidlines.
O Series Data Radio – User Manual Product Labelling When this OEM module is housed inside another unit, the unit must be labelled with the following notice : “This unit contains a device with FCC ID: 900MHz Modules: NI8OM900 and IC: 4630A-OM900. 2.4GHz Modules: NI8OM240 and IC: 4630A-OM240. This device complies with part 15 of the FCC rules.
O Series Data Radio – User Manual Part H – Programming and Diagnostics Programming The O Series OEM module is programmed via the System Port. There are two methods of programming: (a) In Situ : Programming via the 3-wire System Port pins (b) In K-Series : OEM Module can be plugged into a K Series carrier PCB and programmed via the System Port on the K Series. The O Series OEM module is programmed using the TVIEW+ Management Suite : K Series programmer.
C B A © Copyright 2008 Trio DataCom Pty. Ltd. D ISSUE A2 A3 A3 B1 B2 C1 D1 10-30v 1 TEMPERATURE SENSOR (U4) SIO SHUTDOWN RS-232 DRIVERS (U7) INPUT FILTER (FL1) 2 NVRAM (U5) CROWBAR CIRCUIT (Q2) 3 2 3 CHANGE DETAILS ECO No. See Bugzilla Bug # Upissued to A2 and frozen N/A Upissued to A3 N/A See Bugzilla Bug # 2696, 2748,2757, 2770,2819, 2872, 2876, 2877 Up issued to B1 and frozen. N/A Bugs 2990, 2993, 3001: R80-83,86-89=100R. NF parts fixed. Q6=NF. PCB Rev C and schematic update. See ECN.
D C B ISSUE A2 A3 A3 B1 B2 C1 D1 1 C67 1n D16 BAV99W D15 BAV99W D14 BAV99W D13 BAV99W R52 15K 1 2 R53 1K VIN- VIN+ R34 1K Vset R32 10K R30 2K2 F1 3A PSG B C49 1u 2 1 U3 LM431 R33 1K CG CB R37 220R SCRgate 1 Q2 MCR708AT4G Q1 BC857W R31 10K TP1 Input Filter & Protection 3 1 FL1 BNX012-01 5 4 2 2 3 CHANGE DETAILS ECO No.
D C B ISSUE A2 A3 A3 B1 B2 C1 D1 1 1 2 3 4 VCC WP SCL SDA 8 7 6 5 +3V3 NVRAM NC NC NC GND U5 24LC01 C69 100n R107 4K7 R1 220R R21 10K C81 100n 3 1 D18 BAV99W SDA SCL OS GND VCC A0 A1 A2 U4 NF (LM75A) 8 7 6 5 +3V3 SW1 SKQLLA C9 100n R11 220R TEMPERATURE SENSOR 1 2 3 4 R2 220R NVRAM-WP Restore Defaults D19 BAV99W 2 3 CHANGE DETAILS ECO No.
D C B ISSUE A2 A3 A3 B1 B2 C1 D1 1 17 22 5 21 19 18 6 7 14 13 12 10 R2-OUT R2-OUT R1-OUT T1-IN T2-IN T1-IN T2-IN T1-IN C2- C2+ C1- C1+ R2-IN R2-IN R1-IN T1-OUT T2-OUT T1-OUT T2-OUT T1-OUT V- V+ 16 23 4 20 24 1 3 2 15 11 C10 100n 2 3 DRAWN G. Rankin G. Rankin G. Rankin G.
D C B ISSUE A2 A3 A3 B1 B2 C1 D1 RS485-TXD 1 R73 100R R65 NF (22K) 1 3 BAV99W D21 1 17 1 3 2 R76 22K 2 D9 NF (BAV99W) R63 NF (22K) 5 22 R62 NF (22K) +3V3 RS-232 RS-485 D6 NF (BAV99W) X10 3 2 1 LK1 21 19 SPTx 3 2 D7 NF (BAV99W) R2-OUT R2-OUT R1-OUT T1-IN T2-IN T1-IN T2-IN T1-IN C2- C2+ C1- C1+ C65 220n R2-IN R2-IN R1-IN T1-OUT T2-OUT T1-OUT T2-OUT T1-OUT V- V+ 1 2 +3V3 R98 22K 2 3 1 2 3 R91 10K +3V3 +3V3 1 4 DATE 21/02/07 22/03/07 22/03/0
D C B ISSUE A2 A3 A3 B1 B2 C1 D1 1 VIN VOUT VOUT 2 4 R84 1K 2 3 CHANGE DETAILS ECO No. See Bugzilla Bug # Upissued to A2 and frozen N/A Upissued to A3 N/A See Bugzilla Bug # 2696, 2748,2757, 2770,2819, 2872, 2876, 2877 Up issued to B1 and frozen. N/A Bugs 2990, 2993, 3001: R80-83,86-89=100R. NF parts fixed. Q6=NF. PCB Rev C and schematic update. See ECN. N/A PCB Rev D Schematic update see ECN sheet N/A FROM RADIO MODULE 3 +5V2 GND 1 3 DRAWN G.
O Series Data Radio – User Manual Overlay Page 27 © Copyright 2008 Trio DataCom Pty. Ltd.
O Series Data Radio – User Manual Part I – Specifications Parameter 900MHz Specification FCC: 902 – 928MHz, ACMA: 915-928MHz 50Ω 2.4GHz Specification 2.4 - 2.4835MHz Main Antenna Connector Type: MMCX MMCX Auxiliary Antenna Connector Type: MMCX MMCX Frequency Error (over temp range): +/- 1.5ppm +/- 3.0ppm 5.0V ±5% 3.3V ±5% 5.0V ±5% 3.
O Series Data Radio – User Manual Appendix – FCC Approved Antennas Part Number Description Yagi Antennas BMY890K 10dBd, 900MHz Yagi Directional Antenna Bluewave, Marathon Series BMY890G 6.5dBd, 900 MHz Yagi Directional Antenna Bluewave, Marathon Series BGY890K 10dBd, 900 MHz Yagi Directional Antenna Bluewave, Gaurdian Series BGY890G 6.
O Series Data Radio – User Manual HEAD OFFICE 41 Aster Avenue, Victoria, Australia 3201 Phone +61 3 8773 0100 Fax +61 3 9775 0505 sales@triodatacom.com www.triodatacom.com NORTH AMERICA 48 Steacie Drive, Kanata, ON Canada K2K 2A9 Tel: (613) 287 0786 Fax: (613) 591 1022 Toll Free: (866) 844 8746 (TRIO) sales-na@triodatacom.com www.triodatacom.com Innovative and sophisticated digital communications designs products and solutions Page 30 Information subject to change without notice.