Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.: A06033011 Report No.: FCCA06033011 Page:2 of 20 Date: May 12, 2006 Table of Contents 1. DOCUMENT POLICY AND TEST STATEMENT................................................... 3 1.1 DOCUMENT POLICY .......................................................................................... 3 1.2 TEST STATEMENT ..............................................................
Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.: A06033011 Report No.: FCCA06033011 Page:3 of 20 Date: May 12, 2006 1. DOCUMENT POLICY AND TEST STATEMENT 1.1 DOCUMENT POLICY - The report shall not be reproduced except in full, without the written approval of SRT Lab, Inc. - The report must not be used by the applicant to claim that the product is endorsed by NVLAP.
Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.: A06033011 Report No.: FCCA06033011 Page:4 of 20 Date: May 12, 2006 2. DESCRIPTION OF EUT AND TEST MODE 2.1 GENERAL DESCRIPTION OF EUT PRODUCT Remote Controller MODEL NO. POWER SUPPLY CABLE I/O PORT/INTERFACE FREQUENCY BAND CARRIER FREQUENCY NUMBER OF CHANNEL CHANNEL SPACING RF OUTPUT POWER I.F. & L.O.
Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.: A06033011 Report No.: FCCA06033011 Page:5 of 20 Date: May 12, 2006 2.4 DESCRIPTION OF SUPPORT UNIT The EUT was configured by the requirement of ANSI C63.4 and CISPR 22. All interface ports were connected to the appropriate support units via specific cables. The support units and cables are listed below.
Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.: A06033011 Report No.: FCCA06033011 Page:6 of 20 Date: May 12, 2006 5. RADIATED EMISSION TEST 5.1 RADIATED EMISSION LIMIT FCC part15C 15.209 limits of radiated emission measurement for frequency below 1000 MHz FREQUENCY (MHz) DISTANCE (m) FIELS STRENGTH (dBµV/m) 30 - 88 3 40.0 88 - 216 3 43.5 216 - 960 3 46.0 ABOVE 960 3 54.0 FCC part15C 15.
Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.: A06033011 Report No.: FCCA06033011 Page:7 of 20 Date: May 12, 2006 5.2 TEST EQUIPMENT The following test equipment was used during the radiated emission test : EQUIPMENT/ FACILITIES EMI TEST RECEIVER BI-LOG ANTENNA DUE DATE OF CAL. & CAL. CENTER 9 kHz TO ROHDE & AUG. 2006 2750 MHz SCHWARZ ETC 25 MHz TO APR. 2007 EMCO 2 GHz SRT 1GHz-26.5GHz DEC.
Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.: A06033011 Report No.: FCCA06033011 Page:8 of 20 Date: May 12, 2006 5.3 TEST SET-UP Turn Table 1m – 4m EUT Coaxial Power Cable Cable 0.8 m 3/10m Ground Plane Filter To Utility Power EMI Receiver NOTE : 1. The EUT system was put on a wooden table with 0.8m heights above a ground plane. 2. For the actual test configuration, please refer to the photos of testing.
Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. Reference No.: A06033011 Report No.: FCCA06033011 Page:9 of 20 Date: May 12, 2006 TEST REPORT 5.7 RADIATED EMISSION TEST RESULT Temperature: 22℃ Humidity: 68%RH Ferquency Range: 30MHz – 5GHz Measured Distance: 3m Receiver Detector: Peak/QP/AV Tested By: Nick Hsieh Fundamental Reading Frequency (MHz) 433.90 433.90 Correct Antenna Factor Factor (dB) (dB/m) 3.00 3.00 15.64 15.
Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.: A06033011 Report No.: FCCA06033011 Page:10 of 20 Date: May 12, 2006 RX Emission Frequency (MHz) 152.2550 300.1000 502.3050 601.0850 802.4300 932.5900 167.0350 401.3000 428.3400 649.1370 732.9250 840.9600 Correct Antenna Factor Factor (dB) (dB/m) 2.17 3.02 4.13 4.60 5.34 5.86 2.28 3.61 3.75 4.76 5.13 5.53 9.24 13.70 16.13 17.44 21.91 22.85 10.12 15.90 15.
Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.: A06033011 Report No.: FCCA06033011 Page:11 of 20 Date: May 12, 2006 NOTE : 1. Measurement uncertainty is +-/2dB. 2. "*": Measurement value was too low to be detected. 3. Emissiom Level = Reading Value + Ant. Factor + Cable Loss. 4. The field strength of other emission frequencies were very low against the limit. 5.The emission level is lower than equipment ‘s noise.
Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.: A06033011 Report No.: FCCA06033011 Page:12 of 20 Date: May 12, 2006 6.3 TEST SET-UP The EUT was connected to Receiver(or spectrum) by 50Ω coaxial cable. EUT Receiver or Spectrum 6.4 TEST PROCEDURE Please refer to FCC Part15C 15.231. 6.5 EUT OPERATING CONDITION Same as section 2.3 of this report. 6.
Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. FCC ID: TV2EFOBI TEST REPORT Reference No.: A06033011 Report No.
Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.: A06033011 Report No.: FCCA06033011 Page:14 of 20 Date: May 12, 2006 7. FREQUENCY BANDWIDTH 7.1 FREQUENCY BANDWIDTH LIMIT FREQUENCY (MHz) BANDWIDTH LIMIT(kHz) Above 70-900 Above 900 0.25%×Center Frequency(MHz) 0.5%×Center Frequency(MHz) NOTE: 1. Bandwidth is determined at the points 20dB down from the modulated carrier. 7.
Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.: A06033011 Report No.: FCCA06033011 Page:15 of 20 Date: May 12, 2006 7.5 EUT OPERATING CONDITION Same as section 2.3 of this report. 7.6 FREQUENCY BANDWIDTH TEST RESULT EUT: Remote Controller MODEL: TM-TX01 MODE: TX TEST STANDARD: FCC part15 Subpart C 15.
Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.: A06033011 Report No.: FCCA06033011 Page:16 of 20 Date: May 12, 2006 8. RELEASE OR OPERATING TIME 8.1 RELEASE TIME OR OPERATING LIMIT 1. A manually operated transmitter shall employ a switch that will automatically deactivate the transmitter within not more than 5 seconds of being released. 2.
Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. Reference No.: A06033011 Report No.: FCCA06033011 Page:17 of 20 Date: May 12, 2006 TEST REPORT 8.4 TEST PROCEDURE A specific loop antenna was connected to oscilloscope to detect the EUT’s release time. The oscilloscope displayed the EUT’s release time and took a picture of measurement. 8.5 EUT OPERATING CONDITION The EUT is normal use function. 8.
Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. 9. PHOTOS OF TESTING Radiated test-TX FCC ID: TV2EFOBI TEST REPORT Reference No.: A06033011 Report No.
Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. Radiated test-RX FCC ID: TV2EFOBI TEST REPORT Reference No.: A06033011 Report No.
Spectrum Research & Testing Lab., Inc. No. 101-10, Ling 8, Shan-Tong Li, Chung-Li City, Taoyuan, Taiwan, R.O.C. TEST REPORT Reference No.: A06033011 Report No.: FCCA06033011 Page:20 of 20 Date: May 12, 2006 10. TERMS OF ABRIVATION AV. Average detection AZ(°) Turn table azimuth Correct. Correction EL(m) Antenna height (meter) EUT Equipment Under Test Horiz. Horizontal direction LISN Line Impedance Stabilization Network NSA Normalized Site Attenuation PK. Peak detection Q.P.