User Manual

RES-3000-I210+ / I210+RD / I210+c
PA-0115A Rev. 1.4
March 11th, 2011 Page 1 of 6
Introduction
This document will help the SecureMesh user to retrofit the product model RES-3000-I210+,
RES-3000-I210+RD & RES-3000-I210+c in a GE I-210+, GE I-210+RD, GE I-210+c & GE
I-210+cRD meter as intended.
Safety and Assembly Cautions
- Warning: The meter carries lethal voltages. The meter must be completely disconnected
from any external circuits. Failure to observe this practice can result in serious injury or
death.
- Caution: These devices are electrostatic sensitive. It is best to use a grounded electrostatic
mat and wrist strap to prevent electrostatic discharge.
- Important: It is not necessary to completely separate the top of the meter from the base of
the meter for this retrofit procedure. However, if the two parts are completely disconnected
and separated, it is extremely important to keep each meter component together for re-
assembly. This is due to the top section of the meter containing calibration “characterization”
programming for the CTs in the meter base. If these components get mixed up with other
meter components, current measurement errors will occur.
SecureMesh Radio Specifications:
IEEE Standard : IEEE 802.15.4
Power Output : +30 dBm
Radio Sensitivity : -99 dBm
RF Data rate : 250 kbps
Operating Frequency : 2.400-2.483 GHz
Network Topology : Mesh
Modulation : O-QPSK
Physical Dimensions : 2.54” x 3.47”
Antenna : Dipole, 3.5 dBi
SecureMesh retrofit for GE I-210+ / I-210+RD / I-210+c / I-210+cRD meters