Introduction
This document will help the SecureMesh user to retrofit the product model RES-3000-
Focus/FocusAX in a Landis &Gyr Focus® meter as intended.
Safety and Assembly Cautions
- Warning: The meter carries lethal voltages. The meter must be completely
disconnected from any external circuits. Failure to observe this practice can result in
serious injury or death.
- Caution: These devices are electrostatic sensitive. It is best to use a grounded
electrostatic mat and wrist strap to prevent electrostatic discharge.
- Important: It is not necessary to completely separate the top of the meter from the base
of the meter for this retrofit procedure. However, if the two parts are completely
disconnected and separated, it is extremely important to keep each meter component
together for re-assembly. This is due to the top section of the meter containing
calibration “characterization” programming for the CTs in the meter base. If these
components get mixed up with other meter components, current measurement errors will
occur.
Material
Focus meter (must be AMR configured)
Trilliant SecureMesh RES-3000-
Focus/FocusAX .
Mounting Screws - QTY=3 (provided by
L&G,
ref.Trilliant # HS-0029B & HS-0029C)
Self-Retaining Spacers-QTY=3
(provided by L&G, ref. Trilliant # HE-
0033C & HE-0033D)
Serial # & FCC/IC label (provided by
L&G, ref Trilliant #.: HI-0307A)
SecureMesh retrofit for Focus/FocusAX meter

Summary of content (4 pages)