DR5000 Reader Installation Guide Document 403-003-001 © 2019. Transact Holdings Inc. All rights reserved.
Table 1: Revision History Bb Document Part Number Rev. Description Date 403-003-001 A ECO10518. Initial Release.
DR5000 READER INSTALLATION GUIDE - This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Part 15.21: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
D R50 00 R EADER INSTALLATION G UIDE DR5000 READER INSTALLATION G UIDE DR5000 Readers is designed to work with Transact SA3000 Door Access and third- party Access Control systems that use a Wiegand interface. DR5000 Readers support contactless cards using Near Field Communications (NFC) compatible technology. When a contactless card is within range (1.5 inches or less) from the front of the reader, data on the card is read.
DR5000 READER INSTALLATION GUIDE Hardware Kit and Parts List Table 1-1: Table 1-1: Hardware Kit Parts List Item No. Part Number Description Qty 1 044-024-019 1 X 4, 3.5MM TERMINAL BLOCK 2 2 044-028-C07 M2 X 5 18-8 SS BUTTON-HEAD SOCKET CAP SCREW 1 3 044-028-E32 6-20 X .
D R50 00 R EADER INSTALLATION G UIDE M OUNTING O PTIONS Figure 1-3 Figure 1-3 DR5000 Mounting Options Note: Mounting methods other than those shown have not been evaluated by UL. Detailed Installation 1 For installations without a trim plate, use the mounting plate as a guide to drill mounting holes and cable route opening in the mounting surface.
DR5000 READER INSTALLATION GUIDE Note: Install in accordance with the National Electrical Code (NEC), ANSI/NFPA 70, and local codes. When using third-party equipment, to maintain UL compliance, the readers must be connected to a UL294 listed access control panel or power supply with an output voltage of 6-24 VDC. When connecting the DR5000 to the Transact SA3000 Access Control System, typically only TB1 is installed. The SA3000 Door Controller provides power (VCC and GND).
D R50 00 R EADER INSTALLATION G UIDE 8 Secure reader using the tamper resistant security screw (3/32" tamper hex). Hold the top of the reader with one hand and while tightening the screw with the other.
DR5000 READER INSTALLATION GUIDE READER C ONFIGURATION DR5000 Readers can interface to Transact SA3032 Access Controllers using a serial RS-485 connection. The readers are configured the same as the DR4XXXX series and the legacy SE3-CS and SE3-CSPP readers. When prompted for serial reader(s), select either 1 - SE3-CS/CSPP/RDR100 if only one reader is being installed, or 2 SE3-CS/CSPP/RDR100 if two readers are being installed.
D R50 00 R EADER INSTALLATION G UIDE TROUBLESHOOTING Power Indicator is off - If the Power indicator behind the Transact logo remains off when power is applied: • Verify that the proper voltage is being supplied (TB1-1 = +V, TB1- 2 = GND) Red annunciator blinking - DR5000 Readers Red annunciator flashes (approximately 1 second rate) when communication is lost with the SA3000 Door Controller Unit.
DR5000 READER INSTALLATION GUIDE S PECIFICATIONS Physical Size: 1.45"W x 4.0"H x 0.75"D Input Power: 6 - 24VDC 1.4W max Temperature Range: -35 to +66 Celsius Suitable for indoor and outdoor use Wiegand Signal Specifications: Inputs (RED LED, GRN LED, BEEP • 0 - 5.5V maximum • Active when < 2.