Related Document The User Guide and CLI Reference Guide of the product are provided on the resource CD. To obtain the latest product information, please visit the Official Website: http://www.tp-link.com About this Installation Guide This Installation Guide describes the hardware characteristics, installation methods and the points that should be attended to during installation. This Installation Guide is structured as follows: Chapter 1 Introduction.
Contents Chapter 1 Introduction————————————— 01 1.1 Product Overview..........................................01 1.2 Appearance..................................................01 Chapter 2 Installation—————————————— 03 2.1 Package Contents..........................................03 2.2 Safety Precautions.........................................03 2.3 Installation Tools...........................................05 2.4 Product Installation.......................................
L2 Managed Switch Chapter 1 Introduction 1.1 Product Overview TP-Link JetStream L2 Managed Switch, designed for workgroups and departments, provides wire-speed performance and abundant layer 2 management features. It provides a variety of service features and multiple powerful functions with high security. The EIA-standardized framework and smart configuration capacity can provide flexible solutions for a variable scale of networks. ACL, 802.1x and Dynamic ARP Inspection provide robust security strategies.
L2 Managed Switch Note: The port 25–28 of the switch are “Combo” ports. A “Combo” port consists of a RJ45 port and an SFP port, and the two ports share the same LED. Port Feature Model Console Port T2500-28TC 1 10/100Mbps RJ45 Port 24 10/100/1000Mbps RJ45 Port SFP Port 4 4 Console Port Designed to connect with the serial port of a computer or terminal for monitoring and configuring the switch. 10/100Mbps Port Designed to connect to the device with a bandwidth of 10Mbps or 100Mbps.
L2 Managed Switch Chapter 2 Installation 2.1 Package Contents Make sure that the package contains the following items. If any of the listed items is damaged or missing, please contact your distributor. One Power Cord and one Console Cable One Switch This Installation Guide Business Networking Solution Installation Guide One Resource CD Two mounting brackets,eight screws and four feet 2.
L2 Managed Switch Please keep a proper temperature and humidity in the equipment room. Too high/ low humidity may lead to bad insulation, electricity leakage, mechanical property changes and corrosions. Too high temperature may accelerate aging of the insulation materials and can thus significantly shorten the service life of the device. For normal temperature and humidity of the device, please check the following table.
L2 Managed Switch this instant current is strong enough to damage electronic devices, more effective lightning protection measures should be taken. ■■ ■■ ■■ ■■ Ensure the rack and device are well earthed. Make sure the power socket has a good contact with the ground. Keep a reasonable cabling system and avoid induced lightning. Use the signal SPD (Surge Protective Device) when wiring outdoor. Note: For detailed lightning protection measures, please refer to Chapter 3 Lightning Protection.
L2 Managed Switch 3. Turnover the device and attach the supplied rubber feet to the recessed areas on the bottom at each corner of the device. Figure 2-1 Desktop Installation Feet Bottom of the Device Notch ■■ Rack Installation To install the device in an EIA standard-sized, 19-inch rack, follow the instructions described below: 1. Check the grounding and stability of the rack. 2.
L2 Managed Switch Chapter 3 Lightning Protection 3.1 Cabling Reasonably In the actual network environment, you may need cable outdoors and indoors, and the requirements for cabling outdoors and indoors are different. A reasonable cabling system can decrease the damage of induced lightning to devices. Note: It’s not recommended to use Ethernet cables outdoors. When cabling outdoors, please use a signal lightning arrester.
L2 Managed Switch ■■ Requirements for the distance between Ethernet cable and other pipelines are shown in the table. Other Pipelines Min Parallel Net Length L (mm) Down-conductor 1000 PE 50 Service pipe 150 Compressed air pipe 150 Thermal pipe (not wrapped) Thermal pipe (wrapped) Gas pipe Ethernet Cable Min Parallel-overlapping Net Height H (mm) 300 20 20 20 500 500 300 300 300 20 The two diagrams below demonstrate parallel net length and parallel-overlapping net height.
L2 Managed Switch 3.2 Connect to Ground Connecting the device to ground is to quickly release the lightning over-voltage and over-current of the device, which is also a necessary measure to protect the body from electric shock. In different environments, the device may be grounded differently. The following will instruct you to connect the device to the ground in two ways, connecting to the grounding bar or connecting to the ground via the power cord.
L2 Managed Switch Figure 3-1 Connecting to the Grounding Bar Switch (Rear Panel) Grounding Terminal Ground Cable Grounding Bar Note: The grounding bar and ground cable are not provided with our product. If needed, please purchase them.
L2 Managed Switch When equipotential bonding, please note that the cable should be copper wrapped Kelly with its area being 6mm 2 at least. The shorter cable the better, and use a grounding bar to establish an equipotential bonding point. Note: The equipotential bonding cable is not provided with our product. If needed, please purchase it. Use Lightning Arrester Power lightning arrester and signal lightning arrester are used for lighting protection.
L2 Managed Switch Chapter 4 Connection 4.1 Ethernet Port Connect the Ethernet ports of the switch to the network devices by RJ45 cable as the following figure shows. Figure 4-1 Connecting the RJ45 Port RJ45 Port RJ45 Cable 4.2 SFP Port Connect the SFP port to an SFP module. For the switch, if an SFP transceiver (purchased separately) is installed in a slot and has a valid link on the port, the associated RJ45 port will be disabled and cannot be used. Figure 4-2 Inserting the SFP Module SFP Port 4.
L2 Managed Switch Figure 4-3 Connecting the Console Port You can also manage the device through the console port, for details please refer to the CLI Reference Guide on the resource CD. Note: ■■ ■■ ■■ The console port is the first port on the left of the front panel. Please keep the device power off when plugging the console cable. Do not connect the console port with other ports by RJ45 cable. 4.
L2 Managed Switch Note: The figure is to illustrate the application and principle. The power cord you get from the package and the socket in your situation will comply with the regulation in your country, so they may differ from the figure above. 4.6 Initialization After the device is powered on, it begins the Power-On Self-Test. A series of tests run automatically to ensure the device functions properly.
L2 Managed Switch Chapter 5 Configuration 5.1 Configure the Switch via GUI Note: To log on to the GUI of the switch, the IP address of your PC should be set in the same subnet addresses of the switch. The IP address is 192.168.0.x ("x" is any number from 2 to 254), Subnet Mask is 255.255.255.0. 1. To access the GUI of the switch, open a web browser and type in the default management address http://192.168.0.1 in the address field of the browser, then press the Enter key. Figure 5-1 Web Browser 2.
L2 Managed Switch Figure 5-3 Main Page of the Switch 5.2 Configure the Switch Using CLI You can log on to the switch and access the CLI by the following two methods: ■■ ■■ ■■ Log on to the switch by the console port on the switch. Log on to the switch remotely by a Telnet or SSH connection through an Ethernet port. Logon by a Console Port To log on to the switch by the console port on the switch, please take the following steps: 1.
L2 Managed Switch Figure 5-4 ■■ Log in the Switch Logon by Telnet To log on to the switch by a Telnet connection, please take the following steps: 1. Firstly CLI commands about configuring Telnet login mode, login authentication information and Privileged EXEC Mode password should be configured through Console connection. For more details please refer to the CLI Reference Guide on the resource CD. Here we take login local mode as an example. 2. Make sure the switch and the PC are in the same LAN. 3.
L2 Managed Switch Figure 5-7 Enter into the User EXEC Mode For detailed CLI configuration instructions, please refer to the CLI Reference Guide on the resource CD.
L2 Managed Switch Appendix A Troubleshooting Q1. What could I do if I forgot the username and password of the switch? 1. Connect the console port of the PC to the console port of the switch and open hyper terminal. 2. Power off and restart the switch. When you are prompted that “Press CTRL-B to enter the bootUtil” in the hyper terminal, please press CTRL-B key to enter into bootUtil menu shown as the following figure. Enter the reset command to reset the system.
L2 Managed Switch Appendix B Hardware Specifications Item Content IEEE802.3i, IEEE802.3u, IEEE802.3ab, IEEE802.3z, Standards IEEE802.3ad, IEEE802.3ah, IEEE802.3x, IEEE802.1p, IEEE802.1q, IEEE802.1x, IEEE802.1d, IEEE802.1s, IEEE802.1w 10Base-T 100Base-TX 100Base-FX 100Base-LX10 Transmission Medium 100Base-BX10 1000Base-T 1000Base-SX 1000Base-LX 1000Base-LX10 1000Base-BX10 UTP/STP of Cat. 3 or above (maximum 100m) 2-pair UTP/STP of Cat.
FCC STATEMENT This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
BSMI Notice 安全諮詢及注意事項 • 請使用原裝電源供應器或只能按照本產品注明的電源類型使用本產品。 • 清潔本產品之前請先拔掉電源線。請勿使用液體、噴霧清潔劑或濕布進行清潔。 • 注意防潮,請勿將水或其他液體潑灑到本產品上。 • 插槽與開口供通風使用,以確保本產品的操作可靠並防止過熱,請勿堵塞或覆蓋開口。 • 請勿將本產品置放於靠近熱源的地方。除非有正常的通風,否則不可放在密閉位置中。 • 請不要私自打開機殼,不要嘗試自行維修本產品,請由授權的專業人士進行此項工作。 • 此為甲類資訊技術設備,于居住環境中使用時,可能會造成射頻擾動,在此種情況下,使用者會被要求採取某些適當的對策。 限用物質含有情況標示聲明書 限用物質及其化學符號 產品元件名稱 PCB 外殼 鉛 鎘 汞 六價鉻 多溴聯苯 多溴二苯醚 Pb Cd Hg CrVI PBB PBDE ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ 備考1. "超出0.1 wt %" 及 "超出0.01 wt %" 系指限用物質之百分比含量超出百分比含量基準值。 備考2.
For technical support and other information, please visit http://www.tp-link.com/support, or simply scan the QR code. © 2017 TP-Link 7106507692 REV2.0.