TS Smart Cylindrical Lock e-Elite 5000-RF
Index RF Information ······························································ 2 Definitions ···································································· 3 Factory Default Settings ·················································· 3 Important Notes ····························································· 4 Change Master Code ······················································ 5 Add Credentials ····························································· 5 Add a User Code Add Multiple
GENERAL LOCK INFORMATION FOR THE RF FUNCTION APP TS Home 915 wireless smart lock introduction 2019/04/30 TS Home APP can be used as Admin to manage the door locks and management tasks. APP functionality Unlocking Manage wireless gateway Manage clients Manage unlock key Query unlock records Authorize other users to unlock and query unlock records Operations 1.
2. 3. Activate TS Home account Register as a TS Home user by phone or email address Add a gateway Add a networked device→Smart gateway→WI-FI router→Initialize the gateway→Connect WIFI→Binding device→ Set the gateway name→Completed 4. Add lock Add a networked device→Gateway lock→Press the reset button→Pairing success→Set the door lock name→Add completed 5. Add key User→Key management→Add key→Password key→Enter new password→Completed 6.
Definitions Credential: The lock requires a valid credential to operate. A credential can be a Master Code, User Code, or Keycard/Fob. LED Indicator: The LED indicators are located around the keypad of the lock. Lock flashes green LED and/or red LED dependent on inputs. While unlocking, a red LED followed by a green LED means the lock is not programmed and can be unlocked with any 6-10 digit code or Keycard/Fobs.
Important Notes To wake up the touch keypad from idle mode, gently swipe or tap the keypad. While in Factory Default Settings any credential will open the lock until a Master Code is programmed into the lock. When any credential is presented the lock will flash red and then green and unlock. • The Factory Default Setting’s Master Code must be changed before programming any other codes or system settings. A Master Code or User Code can be 6-10 digits (they do not need to be the same code length).
Change Master Code Key Sequence For example, to change Master Code to “555555”, press: Notes • • Factory Default Setting’s Master Code is 123456. It must be changed with the user’s own Master Code immediately. Manufacturer assumes no liability, direct or indirect, due to failure to change Master Code. No other programming will be accepted until Factory Default Setting’s Master Code has been changed. Master Code can be changed at any time.
Add Multiple User Codes Key Sequence 1st User Code Key Sequence Additional User Codes Key Sequence: For example, to add User Codes “202020”, “303030”, and “404040”, press: Notes • The input of additional credentials must start before lock goes into Idle Mode (12 seconds). If the lock goes into Idle Mode, start the key sequence from the beginning. Same User Code cannot be added twice. To exit, press asterisk (✴) or wait until the lock goes into Idle Mode (12 seconds).
Delete Credentials Delete User Codes Key Sequence For example, to delete User Code “202020”, assuming the Master Code is “555555”, press: Delete User Key Cards Key Sequence Notes • The Master Code cannot be deleted. Multiple Keycards/Fobs can be deleted during the same programming sequence (like Additional User Codes Key Sequence). To exit, press the asterisk (✴) or wait until the lock goes into Idle Mode (12 seconds).
System Settings Passage Mode Key Sequence Notes After creating a Passage Code, entering it will activate the Passage Mode function. The lock will remain actively unlocked until the Passage Code or Master Code is entered to deactivate (or Disable) the function. Dual Verification Mode Key Sequence Notes Dual Verification Mode, when enabled, requires 2 valid credentials to operate the lock. A credential can be a Master Code, User Code, or Keycard/Fob.
Reset Lock to Factory Default Settings without a Master Code Steps 1. Locate the reset button on the battery holder. 2. Press and hold the reset button. After approximately 4 seconds, the lock will beep 2 times, and you can release the reset button. 3. The green LED indicator will light up and it will beep 1 time indicating lock is reset. Result Lock is reset to Factory Default Settings. All codes are deleted and Master Code changes to 123456.
CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS. FCC Warning: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.