User Manual

7-STAGE CHARGING
1. Desulphation:
Pulse charges the battery to break down
the buildup of lead sulphate crystals. Lead sulphate crystals
can occur when a battery has been discharged or left
unused for a period of time, seriously affecting the perfor-
mance and lifetime of the battery.
2. Soft Start: A slow steady buildup of the charging process
that limits the power supplied to protect the battery.
3. Bulk Charge: The main part of the charge process where
80% of the charge is applied.
4. Absorption: Fully charges the battery by slowly reducing
the charge rate to allow the battery to absorb more power.
5. Battery Test: An automatic test to determine the battery
condition after charging. If further charging required the
Recondition stage is selected, if fully charged the battery
goes into Float status.
CUPPENT VOLTAGE
12
6. Recondition: Unique charge state to recover deeply
discharged batteries.