Safety Safet f y Precautions Operating Instructions Installation Instructions Care aand nd C Cleaning leeaning Troubleshooting Troubleshoo oubleshooting Tips Remote Con Control ntrol Instructions USER MANUAL T Portable Type Room Air Conditioner RAC-PD0811CRU RAC-PD1011CRU RAC-PD1211CRU RAC-PD1412CRU RAC-PD1412HRU Warning notices: Before using this product, please read this manual carefully and keep it for future reference. change without prior notice for product improvement.
User Manual Safety Precautions .................................................................................................................... 3 Unit Specifications and Features ........................................................................................ 5 Operating Instructions ............................................................................................................ 6 Installation Instructions ...............................................................................
To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications. WARNING: This symbol indicates the possibility of death or serious injury. CAUTION: This symbol indicates the possibility of injury or damage to property. WARNING Please read through these instructions before you start the installation process.
Safety Precautions WARNING • DO NOT allow children to play with the air conditioner. Children must be supervised around the unit at all times. • If the air conditioner is knocked over during use, turn off the unit and unplug it from the main power supply immediately. Visually inspect the unit to ensure there is no damage. If you suspect the unit has been damaged, contact a technician or customer service for assistance.
OPERATING INSTRUCTIONS Preparation control panel horizontal louver blade (automatic swing) handle (both sides) upper air filter (models RAC-PD1412CRU/ RAC-PD1412HRU have a separate, detachable filter inside) Panel Operating Instructions upper air intake drain outlet air outlet lower air filter lower air intake drain outlet (only for pump heating mode) power cord buckle Caster Front power cord outlet power plug socket bottom tray drain outlet 6&$/( Rear Design and Compliance Notes Design N
Control Panel Features Heat Mode Indicator Light Operating Instructions Swing Button Timer Button Mode Button Follow Me Up ( LED Display ) and Down ( Buttons ) Fan Button Sleep Button Power Button Swing Button Power button Used to initiate the Auto Swing feature. When the operation is ON, pressing the SWING button can stop the louver at the desired angle. Power switch on/off. Timer button Used to initiate the SLEEP operation.
Operating Instructions COOL operation • • • Press the “MODE” button until the “COOL” indicator light comes on. Press the ADJUST buttons Up ( ) or Down ( ) to select your desired room temperature. The temperature can be set within a range of 17°C~30°C/62°F~86°F. Press the “FAN SPEED” button to choose the fan speed. • Press the “FAN SPEED” button to choose the fan speed. The temperature cannot be adjusted. • Do not connect the duct to a window.
Other Features FOLLOW ME/TEMP SENSING feature This feature can be activated from the remote control ONLY. The remote control serves as a remote thermostat allowing for the precise temperature control at its location. To activate the Follow Me/Temp Sensing feature, point the remote control towards the unit and press the Follow Me/Temp Sensing button. The remote control will send this signal to the air conditioner until press the Follow Me/Temp Sensing button again.
WATER DRAINAGE (cont.) • Remove the lower drain plug NOTE Continuous drain hose Drain hose adaptor During heating mode, remove the lower drain plug from the back of the unit and install the drain connector (5/8” universal female mender) with 3/4” hose (locally purchased). For models without drain connector, just attach the drain hose to the hole. Place the open end of the hose adaptor directly over the drain area in your basement floor. Units with Pump Only Delivery lift <1.
INSTALLATION INSTRUCTIONS Choosing the Right Location Your installation location should meet the following requirements: Installation Instructions 30 c 12 in m ch • Make sure that you install your unit on an even surface to minimize noise and vibration. • The unit must be installed near a grounded plug, and the Collection Tray Drain (found on the back of the unit) must be accessible. • The unit should be located at least 30 cm (12”) from the nearest wall to ensure proper air conditioning.
Tools Needed • • • • Medium Phillips screwdriver Tape measure or ruler Knife or scissors Saw (optional, to shorten window adaptor for narrow windows). Accessories Your Window Installation Kit fits windows 67.5-123 cm (26.5”-48”) and can be shortened for smaller windows.
Window Installation Kit Exhaust hose Exhaust hose assembly Step One: Preparing the exhaust hose assembly Press the exhaust hose into the window slider adaptor and unit adaptor, clamp automatically by elastic buckles of the adaptors.
NOTE Once the Exhaust Hose assembly and Adjustable Window Slider are prepared, choose from one of the following two installation methods. Foam seal B (Adhesive type-shorter) Type 1: Hung window installation 1. Cut the adhesive foam seal A and B strips to the proper lengths, and attach them to the window sash and frame as shown. 2. Insert the window slider assembly into the window opening. 3. Cut the non-adhesive foam seal C strip to match the width of the window.
Foam seal B (Adhesive type-shorter) Type 2: Sliding window installation 1. Cut the adhesive foam seal A and B strips to the proper lengths, and attach them to the window sash and frame as shown. 2. Insert the window slider assembly into the window opening. 3. Cut the non-adhesive foam seal C strip to match the window height. Insert the foam seal between the glass and the window frame to prevent air and insects from getting into the room. 4.
CARE AND CLEANING Safety Precautions • • • • Always unplug the unit before cleaning or servicing. DO NOT use flammable liquids or chemicals to clean the unit. DO NOT wash the unit under running water. Doing so causes electrical danger. DO NOT operate the machine if the power supply was damaged during cleaning. A damaged power cord must be replaced with a new cord from the manufacturer.
TROUBLESHOOTING TIPS Malfunction Diagnosis Please check the machine according to the following table before calling for service: Problem Possible Cause Troubleshooting P1 Error Code. The water collection tray is full. Turn off the unit, drain the water from the water collection tray and restart the unit. In COOL mode: room temperature is lower than the set temperature. Reset the temperature. The air filter is blocked with dust or animal hair.
REMOTE CONTROL INSTRUCTIONS Remote Control Specifications Model Rated voltage Signal receiving range Environment RG57H4(B)/BGEFU1 3.0V (Dry batteries R03/LR03x2) 8 m (approx. 26 ft.) -5°C ~ 60°C (23°F ~ 140°F) Function Buttons Before you begin using your new air conditioner, make sure to familiarize yourself with its remote control. The following is a brief introduction to the remote control itself.
Handling the Remote Control NOT SURE WHAT A FUNCTION DOES? Refer to the Operating Instructions section of this manual for a detailed description of how to use your air conditioner. SPECIAL NOTE Button designs on your unit may differ slightly from the example shown. If the unit does not have a particular function, pressing that function’s button on the remote control will have no effect.
Remote LED Screen Indicators Transmission Indicator Lights up when remote sends signal to unit MODE display Displays the current mode, including: ON/OFF display Appears when the unit is turned on and disappears when it is turned off AUTO COOL DRY HEAT FAN TIMER ON display Displays when TIMER ON is set TIMER OFF display Displays when TIMER OFF is set ECO display Not available on this unit Battery display Low battery detection SLEEP display Displays when SLEEP function is activated FOLLOW ME display Indic
Basic Functions SETTING THE DESIRED TEMPERATURE The operating temperature range for this unit is 17-30°C (62°F-86°F). You can increase or decrease the set temperature in 1°C (1°F) increments. 2 3 1 AUTO operation In AUTO mode, the unit will automatically select the COOL, FAN, HEAT or DRY mode based on the set temperature. 1. Press the MODE button to select Auto mode. FOLLOW ME 2. Set your desired temperature using the Temp button. or Temp 3. Press the ON/OFF button to start the unit.
Basic Functions (cont.) FAN operation 1. Press the MODE button to select FAN mode. 2. Press FAN button to select the fan speed: AUTO, LOW, MED or HIGH. 3. Press the ON/OFF button to start the unit. 3 1 NOTE 2 You cannot set temperature in FAN mode. As a result, your remote control’s LCD screen will not display temperature. FOLLOW ME HEAT operation 1. Press the MODE button to select HEAT mode. 2. Set your desired temperature using the Temp button. 2 4 or Temp 3.
Timer Functions 1 2 TIMER ON x5 TIMER ON Your air conditioning unit has two timer-related functions: TIMER ON - sets the amount of time after which the unit will automatically turn on. TIMER OFF - sets the amount of time after which the unit will automatically turn off. TIMER ON function 3 1sec 4 2sec The TIMER ON function allows you to set a period of time after which the unit will automatically turn on, such as when you come home from work. 1. Press the TIMER ON button.
Timer Functions (cont.) 3. Wait 2 seconds, then the TIMER OFF function will be activated. The digital display on your remote control will then return to the temperature display. T im er on NOTE Continue to press TIMER ON or TIMER OFF until desired time is reached. FOLLOW ME 1 2 TIMER ON X12 When setting the TIMER ON or TIMER OFF functions, up to 10 hours, the time will increase in 30 minute increments with each press. After 10 hours and up to 24, it will increase in 1 hour increments.
How to Use the Advanced Functions SLEEP Function The SLEEP function is used to decrease energy use while you sleep (and don’t need the same temperature settings to stay comfortable). This function can only be activated via remote control. Note: The SLEEP function is not available in FAN or DRY mode. FOLLOW ME SWING Function Used to stop or start louver movement and set the desired up/down air flow direction. The louver angle changes in 6 degree increments with each press (not all models).
NOTES • The device may comply with local national regulations. In Canada, it should comply with CAN ICES-3(B)/NMB-3(B). In USA, this device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
WARNING: Chemical Burn Hazard. Keep batteries away from children. This product contains a lithium button/coin cell battery. If a new or used lithium button/coin cell battery is swallowed or enters the body, it can cause severe internal burns and can lead to death in as little as 2 hours. Always completely secure the battery compartment. If the battery compartment does not close securely, stop using the product, remove the batteries, and keep it away from children.