Installation Instructions

FormNo.3364-664RevA
ReplacementTurbineHubKit
2009andBeforeProForceDebrisBlower
ModelNo.119-6164
InstallationInstructions
Installation
LooseParts
Usethechartbelowtoverifythatallpartshavebeenshipped.
Description
Qty.
Use
Holderbearing1
Innerhousing1
Finspacer4
Bolt,5/16x10inches
4
Flangenut,5/16inch
4
Frontbearingcap2
O-ring
1
Screw,1/4x3/4inch
4
Installturbinehubkit
1.Removethefanshaftandbearingsfromtheblower
(Figure1).RefertotheToroProForceDebris
BlowerServiceManualforthedisassemblyand
assemblyinstructionsoftheblower.
Figure1
1.Fanshaft
2.Bearings
2.Mountthebearingholdertothefanshaftand
bearingwiththefrontbearingcapand(4)1/4x3/4
inchscrews,positioningthecomponentsasshown
in
Figure2.Torquethescrewsto89–90in-lbs.
Figure2
1.Bearingholder
3.Screws(4)
2.Frontbearingcap
3.InstalltheO-ringintothenewinnerhousing
andliberallyapplysoapywateraroundtheO-ring
(Figure3).
©2010—TheToro®Company
8111LyndaleAvenueSouth
Bloomington,MN55420
Registeratwww.Toro.com.
OriginalInstructions(EN)
PrintedintheUSA.
AllRightsReserved