Instructions / Assembly

1
WARNING
DISCONNECT POWER BEFOR E RELAMPING OR WIRING THE FIXTURE.
READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING IN STALLATIO N.
NOTICE
The important safeguards and instructions outlined on this sheet cannot cover all possible conditions and situations that may occur.
It must be understood that common sense, caution and care are factors that cannot be built into any product.
Caution and care must be supplied by the person(s) installing, operating and caring for this lighting fixture.
This fixture is designed to be mounted on a correctly installed standard round or octagon box or a through wiring box
with a plaster frame. The box must be securely mounted to the structure of the building.
The crossbar and hardware supplied should be used. Directly mounting the fixture to the outlet box may make it impossible to
correctly align the fixture.
INSTALLATION INSTRUCTIONS
FIXTURE PREPARATION
Remove the fixture, parts and parts bag(s) from the carton.
NOTICE:
Before discarding the carton, double check to make certain that all parts are found
FIXTURE INSTALLATION
New construction: Double check that AP
PROVED BOX and SUPPORT
were correctly installed following the manufacturer's instructions.
Remodeling (with enclosed ceiling) Install APPROVED BOX and SUPPORT
following manufacturer's instructions.
1. Turn power off at the circuit breaker or the fuse box.
3.
Fasten the ground wire to the green or bare
copper wire in the outlet box.
4. Fasten the white fixture lead to the white wire in the outlet box
with an approved fastener (wire nut). Tightly wrap the connection
with electrical tape so that the connection seals the end of the fastener.
TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH
ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL/BUILDING CODES .
INSTALLATION AND MAINTENANCE OF THIS UN IT REQUIRES AN ELECTRICIAN OR
CERTIFIED FACTORY TRAINED TECHNICIAN.
If an existing fixture is being replaced, remove it and note to which of the wires in the outlet box the fixture was attached.
DO NOT SEPARATE ANY OTHER WIRES THAT MAY BE IN THE BOX. DO NOT DAMAGE THE INSULATION OF OLDER WIRING.
In regular circumstances the BLACK wire will be the "Hot" lead and the WHITE wire will be the "Neutral" or "Common" lead.
A GREEN or BARE COPPER wire is the "Ground". In older buildings it is always good practice to reconfirm the polarity of the wiring.
approved fastener
(wire nut)
electrical tape
CAUTION
Ap
(Wi
Never fasten the ground wire to the black or "hot" wire!
Failure to follow this instruction could result in serious
injury or death!
WARNING
Make sure that there is no exposed wire or strands
that could cause a dangerous short circuit !
WARNING
2. Screw the mounting bracket to the outlet box.

Summary of content (2 pages)