ADV Data Logger & Advanced Sensor Node User Manual (Eng.) Version 1.
1. Introduction The industrial datalogger supports 4 channels and supports up to 12 Advanced Sensor Nodes for each channel. (Up to 28 sensor nodes are supported.) 1-1.
1-3.
1-4.
1-5. Sensor Node Setting Sensor Node DIP Switch Operating Item DIP Switch ON : 1(High) Case 1 RS-485 TX Line termination resistor setting 2 Unspecified 3 High : Single-Ended, Low : Differential 4 High : Current, Low : Voltage 5 Sensor Node ID : Bit 3 6 Sensor Node ID : Bit 2 7 Sensor Node ID : Bit 1 8 Sensor Node ID : Bit 0 Red LED Status Description Green Blue Power On : LED On RS-485 Data Flow Status: LED Blinking MCU Status: LED Blinking 1-6.
1-6.
1-6.
2-2. Connection of Management Console 2.2.1 Console cable provided by the product is to be connected to Console Port (RJ-45) at the front panel of TEK-SYRX as well as PC & laptop computer which terminal emulation software is installed. *. Terminal emulation Download (Free software) Tera Term Home Page http://ttssh2.sourceforge.jp/ 2.2.2 Configuration of terminal communication is as follows: *. Protocol : Serial *. Port : It is to check through Device Manager (Port) of PC or laptop computer *.
3. CLI (Command Line Interface) 3-1. Login Use the 'root' account when logging in. (No password) The login directory is / home / root. Other commands are the same as for Linux. < Examples > login as: root root@TEL:~# root@TEL:~# pwd /home/root root@TEL:~# 3-2. Hostname Configuration The Hostname of the Data Logger can be changed by editing the / etc / hostname file. Changes to Hostname will be reflected after Reboot. < Examples > root@TEL:~# vi /etc/hostname Data_Logger root@TEL:~# reboot ##.
3-4. Configure Network Network settings can be changed by editing the /etc/default/ipconfig.conf file. IP Assignment Mode (Static or DHCP), IP Address, Netmask, Default Gateway can be set. < Examples > root@TEL:~# vi /etc/network/interfaces # /etc/network/interfaces -- configuration file for ifup(8), ifdown(8) # The loopback interface auto lo iface lo inet loopback # Wired or wireless interfaces auto eth0 iface eth0 inet static address 192.168.0.101 netmask 255.255.255.0 network 192.168.0.0 gateway 192.168.
3-6. Configure External Sensor Node Sensor node's impact measurement range and sampling period setting can be set by editing the /home/root/kslogger/cmdfile_#.txt file. • '#' in the file name means Channel number. Create and manage configuration file for 4 channels (1 ~ 4 channels, 16 IDs for each channel, 00 ~ 15) The 'cmdfile _ #.
3-7. Data collection command Data collection for each channel and sensor node is performed through the ‘./kslogger start’ command. When the data collection command is executed, the operating channel refers to the ‘parameter.txt’ data. Channel numbers can be assigned from 1 to 4 Additionally, you can manually set the channel to be executed like ‘./kslogger start –h 1,2. When the ‘kslogger’ command is executed, data is collected for the sensor node defined in ‘cmdfile_#.
3-9. Check system information You can check HW, SW version and Serial number information with the ‘sysinfo’ command of ADV Data Logger. < Examples > root@TEL:~# sysinfo Product Name : Advanced DataLogger Serial Number : DL0022150001 H/W Version : 2.0.0 S/W Version : 0.9.6 § 15.105 Information to the user.