IMPORTANT! Installaon of TOGGLED LED tubes requires modicaon of the
wiring within the exisng uorescent xture. Please follow the specic instrucons
below. If you have any quesons or comments, please feel free to contact
1-844-TOGGLED.
THIS KIT INCLUDES:
(1) Installaon Instrucon Booklet
(1) TOGGLED LED lamp (D416)
(2) UL listed wire nuts
(2) UL listed G13 lampholders
(1) Fixture modicaon label
TOGGLED is an company
Fixtures may contain one or more lamps. See the table
below about intended retrofit fixtures and quantities
11-01718-AE
En
Scan to view
installaon video
escanear para ver el
video de instalación
balayez ce code pour
visionner la vidéo
d’installaon
toggled.com/installaon
If you have any problems or quesons, contact our tech support
team at 1-844-864-4533 Monday-Friday, 8-5pm EST or email
support@toggled.com
Si ene algún problema o desea realizar una pregunta, co-
muníquese con nuestro equipo de asistencia técnica llamando
al teléfono 1-844-864-4533, de lunes a viernes, de 8 a. m. a 5 p.
m. (hora estándar del este), o envíenos un correo electrónico a
support@toggled.com
Si vous avez des problèmes ou des quesons, veuillez communi-
quer avec notre équipe de souen technique par téléphone au
1 844 864 4533, du lundi au vendredi, de 8 h à 17 h (HNE), ou
par courriel au support@toggled.com
PLEASE DO NOT RETURN THIS
PRODUCT TO THE STORE
POR FAVOR NO DEVUELVA ESTE
PRODUCTO A LA TIENDA
S’IL VOUS PLAÎT NE RETOURNEZ
PAS CE PRODUIT AU MAGASIN
WARNING – Risk of re or electric shock. LED Retrot Kit installaon
requires knowledge of luminaires electrical systems. If not qualied, do
not aempt installaon. Contact a qualied electrician.
WARNING – Risk of re or electric shock. Install this kit only in the
luminaires that have the construcon features and dimensions shown in
the photographs and/or drawings.
Do not make or alter any open holes in an enclosure of wiring or electrical
components during kit installaon.
WARNING – To prevent wire abrasion, do not expose wiring to edges of
sheet metal or other sharp objects.
WARNING – To avoid potenal re or shock hazard, do not use this retrot
kit in luminaires employing shunted bi-pin lampholders.
WARNING – This xture must be grounded and installed in accordance
with local and naonal electrical codes, by a person familiar with the
construcon and operaon of the product and the hazards involved.
Note: Shunted lampholders are found only in uorescent luminaires with
Instant-Start ballasts. Instant-Start ballasts can be idened by the words
“Instant Start” or “I.S.” marked on the ballast. This designaon may be in
the form of a statement pertaining to the ballast itself or may be combined
with the marking for the lamps with which the ballast is intended to be
used, for example F40T12/IS. For more informaon, contact TOGGLED.
Installers should not disconnect exisng wires from lampholder terminals to
make new connecons at lampholder terminals. Instead installers should cut
exisng lampholder leads away from the lampholder and make new electrical
connecons to lampholder lead wires by employing applicable connectors.
This device is not intended for use with emergency exits.
Refer to www.toggled.com/dim for dimmer compability.