User's Manual Part 5

Digital Liquid Cooled UHF
TV Equipment
Use of commands and description of indicators
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
CONTROL KEYS FUNCTIONS DISPLAY/COMMENTS
Calls up the "EXCITER Level 1" window.
Calls up the "AMPLIFIERS" window.
Calls up the «INTERLOCK» window
Calls up the "POWER SUPPLY" window.
Calls up the "PA LEVELS" window.
* : Operating only when there is more than one cabinet.
** : Operating only when there is more than one amplifier.
MESSAGE FUNCTIONS DISPLAY/COMMENTS
Gives the window name.
Shows the number of the particular cabinet
to which the data displayed in this window
refer.
Shows the number of the particular
amplifier to which the data displayed in this
window refer.
Displays the analogue values of the
currents in the transistors T1 to T6.
Indicates whether the amplifier is present
or missing.
PRES / MISSING (1)
Indicates the status of the amplifier auto
diagnostic system.
INTRNL OK / INTRNL FAULT (1)
INTRNL: Internal
Indicates the status of the amplifier
Overdrive (RF current) protection system.
OV CUR OK / OV CUR FAULT (1)
Indicates the status of the amplifier
temperature protection system.
TEMP OK / TEMP FAULT (1)
Indicates the status of the amplifier SWR
protection system.
VSWR OK / VSWR FAULT (1)
(1) A fault-free status is displayed in normal video (on black background or green background in case
of colour tactile screen). A faulty status is displayed in reverse video (on white background or red
background in case of colour tactile screen). The transmitter can operate while the status of the
diagnostic systems of one or several RF amplifiers is "FAULT".
9932 V2
45321648.01 108 B E
Checked
156 / 192
Numéro / Number Doc. Rev. Lan
g
u.
27/06/2006
Pa
g
e

Summary of content (37 pages)