Product Requirement Document (PRD) For ZigBee Module (DVT) LITEON code name: WZ401F Version 0.12 Date: December 18th, 2012 Lite-On Technology Thinkeco Inc 720 S. Hillview Drive 148 Madison Ave Milpitas, CA 95035 New York, NY 10016 © Copy Right 2012, LITE-ON Technology and Thinkeco Inc.
Revision History Version 0.01 0.02 0.03 0.04 0.05 0.06 0.07 Date 8/08/2012 8/20/2012 8/21/2012 8/29/2012 8/30/2012 9/10/2012 9/12/2012 Author Stanley Wang ThinkEco ThinkEco ThinkEco ThinkEco ThinkEco Eddie.ZG.Chen 0.08 0.09 0.10 9/12/2012 9/18/2012 9/18/2012 Thinkeco LITEON Thinkeco 0.11 9/18/2012 LITEON 0.
Contents 1. Purpose and Scope................................................................................................................................ 4 2. Product Requirements .......................................................................................................................... 4 3. 2.1 Block Diagram ............................................................................................................................... 4 2.2 Requirements ...........................
1. Purpose and Scope The purpose of this document is to establish the product requirements for the standard range ZigBee module. WZ401F-DVT has two SKUs, please see below description. Basic SKU: Equips off-board antenna; Be deployed on GTWY; Be certified by FCC; RD SKU: Equip Johansson 2450AT18A100 antenna, For RD purpose; 2. Product Requirements 2.1 Block Diagram Fig. 1 WZ401F-DVT The GPIO interface of the module is specified in Sec.2.3 below.
Receiver sensitivity -94 dBm (typical at 1% PER for 20 byte packets) (for RD SKU) o LITEON suggest RX sensitivity to be -94dBm, the reason as below: o -96dBm is the criterion for MC13224; o WZ401F (normal range) add a connector; o Trace is changed because we have to consider the shielding case; Outdoor line of sight range 300m (1% PER for 20 byte packets) (for RD SKU) Ceramic antenna shall be matched for return loss better 10dB over 2.4…2.
RESETB Power (VCC, GND) JTAG (TDO, TDI, TCK, TMS, RTCK) ADC0, ADC4 With 4 connections for GND and 2 connections for VCC, this amounts to a total of 402 external connections. 2.4 Mechanical This figure illustrates the intended component layout and scale. The module needs to be suitable for pick and place assembly. 3. Software ThinkEco will be responsible for all software development and support.
Preliminary testing procedure reported in the document Simplified Test ZigBee Modules v0.02 09-10-2012.pdf © Copy Right 2012, LITE-ON Technology and Thinkeco Inc.
4. Manufacturing Testing Process Conduct module tests Collect and keep all logs for passed and failed units Retest those failed units. Send Thinkeco log files of passed or failed units for the first time, and log files of those unit failed at the first time but passed at the 2nd time Wait for Thinkeco’s log review and feedback Receive Thinkeco’s approval to deliver the units to gateway production line. 5.
Delivery packaging: Each product will be stocked and delivered inside an ESD bag Shipping box: TBD E-file: Each shipment will be anticipated by the E-file reporting all the tracking information requested by Thinkeco. The e-file will be sent via email. 7. Appendix 8.1 Crystal Spec See included file ZigBee Module - Excerpt MC1322x Data Sheet - Crystal Spec.pdf 8.2 RF Electrical Characteristics See included file ZigBee Module - Excerpt MC1322x Data Sheet - RF Electrical Characteristics.pdf 8.
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
End Product Labeling This transmitter module is authorized only for use in device where the antenna may be installed such that 20cm may be maintained between the antenna and users.
Radio Frequency (RF) Exposure Information The radiated output power of the Wireless Device is below the Industry Canada (IC) radio frequency exposure limits. The Wireless Device should be used in such a manner such that the potential for human contact during normal operation is minimized. This device has also been evaluated and shown compliant with the IC RF Exposure limits under mobile exposure conditions. (antennas are greater than 20cm from a person's body).