REB Installation Guide Revision No.3 Approval Signature Date PROPRIETARY NOTICE This document contains information proprietary to Thermo King Corporation. It is submitted in confidence and is to be used solely for the purpose for which it is furnished and returned upon request. This document and such information is not to be reproduced, transmitted, disclosed or used otherwise in whole or in part without the written authorization of Thermo King Corporation. Revision History: Revision Level 1 S. Ed.
Page 2 of 15 Thermo King Corporation Proprietary Information
Regulatory Statements: FCC: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications made to this equipment not expressly approved by Thermo King Corporation may void the FCC authorization to operate this equipment.
IC: This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence.
1. Introduction: This document will describe how REB and the antenna system are installed in the Thermo King SB unit in the factory and in the field. 2. Installation of REB to the mother board SR3 controller. a. Plug- in REB with plastic housing to the SR3 controller board via connector RJ98. b. Secure board to the SR3 controller board using two screws provided in the kit. c. Mount the boards to the metal control box. See drawing for details. d. Connect antenna connectors to corresponding REB connectors.
Page 6 of 15 Thermo King Corporation Proprietary Information
3. REB Wi-Fi Configuration: 3.1 Required Materials: REB – Radio Expansion Board TDAC- Tracking Diagnostic and Configuration Tool- PC based application to configure REB REB adapter cable PN;41-9171 Wintrac cable : 204-918 + 44-9417 REB reset cable 3.2 Instructions: a) Connect Wintrac cable to the REB adapter cable as shown in figure 1. b) Connect reset cable as shown in figure 1.
Figure 1. d. Launch TDAC application in your PC. See Figure 2. Figure 2 e. Turn TK unit ON (Controller and HMI running). f. Push and release reset button and immediately click START button in the TDAC application (Note: The TDAC will not work if back-up battery is still connected make sure to unplug it.) See figure 3 for details.
Figure 3 g. The status will change to “Connection established” once the TDAC has successful connection to REB. The TDAC screen display will change- adding more icons for you to configure REB with Wi-Fi settings . See Figure 4 Will appear when connected to REB. Figure 4 h. Click on Wi-Fi Network icon to configure REB to connect to the Website via Wi-Fi. See Figure 5.
Figure 5 i. Click on WIFI 1 and input required data/parameters to connect to your local Wi-Fi network. This data will be provided by your local IT or TK Customer Service. Note: At present, Key management configuration is limited to the following: WEP 64 WEP 128 WPA WPA2 j. Review your configuration and click update. At this point, Wi-Fi connection profile has been created. k. To add more Wi-Fi connection profiles click WIFI 2. At present, you are limited to a maximum of 5 Wi-Fi connection profiles.
Figure 7 n. Check if unit is reporting in the website. Wi-Fi icon in the website indicates unit is connected via Wi-Fi.
4. Troubleshooting and Diagnostics a.
GPRS LED Definition : LED blinks green twice a second when on the network.
LED blinks green once a second when off the network. Armed (No Change), Countdown and full SCOM modes (New modes): LED blinks green every three seconds when on the network. LED blinks amber every three seconds when off the network. Conservative and Full Null (replaces sleep): LED blinks red every five seconds until the ARM is switched, after this LEDs cannot be switched. Limited SCOM (New mode, effectively a short wakeup from Conservative mode): LED blinks green every five seconds when on the network.
5.1.1 Full-On: Conditions: Reefer is running, 8xp is high Behavior: The REB reporting to website every hour for U.S. and 15 minutes for ESA, the power status in the website is “ON” 5.1.2 Countdown and Conservative Pre-Conditions: HMI is turned-off, Controller OFF, 8xP is low Behavior: a. Very similar to full-on. It will periodically reports to the website dependent on the logging interval set when unit is OFF and website will display as unit OFF.