MicroTouch Control Installation Operation Manual thermasol.
MicroTouch Control and Steamhead Installation Instructions 1 Important Information before You Install The MicroTouch Control must be installed inside the shower. The MicroTouch control will only function on the current TFX, SSA and PRO Series generators. The control should be installed 60" from the floor of the shower and away from the steamhead. The steamhead should be installed 24" from the floor and 6" from any wall.
MicroTouch Control and Steamhead Installation Instructions 2 Tools and Materials Controller (Round style shown here) Silicone Materials needed: o MicroTouch control o CAN bus cable o Silicone o Other materials as required Parts enclosed with the generator 50-foot control data cable (included with Pro or AF Series generator) Item 03-6152-050 Tools needed: o Pipe wrench o Tubing cutter o Wire cutters or wire strippers o Adjustable wrench o Screwdriver (Phillips and regular) o Solder and flux o 1-1/16” m
MicroTouch Control and Steamhead Installation Instructions 4 Control Installation and Data Cable Connection Back of Control Route the data cable (included with generator) through the finished wall to the back side of the control. (The other end of the cable runs to the steam generator location.) NOTE: It is recommended to run the cable through electrical conduit. Connector Detail DO NOT pinch, nail, staple, wedge, or bind the data cable.
MicroTouch Control and Steamhead Installation Instructions 5 Sealing Control THESE STEPS MUST BE TAKEN FOR CORRECT INSTALLATION of the control. A Coat the entire groove on the control back with supplied waterproof silicone to fully seal the control to the wall. Completely seal the control to the wall so moisture does not collect behind it. Place the control on the wall pressing firmly. (You may need to tape the control into place until the silicone dries.
MicroTouch Control and Steamhead Installation Instructions 6 Steamhead Installation Steamhead Location DO NOT install the steamhead near the seating area or the user. DO NOT forget to install the steamhead rough-in fitting! C I nstall the steamhead 24" from the floor or bathtub rim and 6" from any corner. Steamhead is to be mounted as far as possible from typical bathing position (seated or standing) and installed as far from the in-shower controller as possible.
MicroTouch Control and Steamhead Installation Instructions D Once the shower wall is complete and the housing is sealed to the wall, remove the protective cap and insert the steamhead into housing. Use the supplied silicone to adherethe steamhead to the wall sealing out any water from getting behind the head. Use supplied o-ring lubricant to assist in steam head installation. A very small amount is all that is need directly on the o-rings.
MicroTouch Control and Steamhead Installation Instructions 7 Operation A Taking a Steam Bath On your ThermaSol MicroTouch Control, touch and release the power icon twice to power on. To turn off the steam unit touch and release the power icon once. Power on is verified when the control face shows lit LEDs and turns dark if power is off. C Power Flush ThermaSol’s internal diagnostic system will alert you when a Power Flush cleaning is needed (Maintenance mode) by LEDs running counterclockwise.
MicroTouch Control and Steamhead Installation Instructions Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. THERMASOL.COM I 800.776.
1958 STEAM WAY ROUND ROCK, TX 78665 PHONE: 800.776.0711 | FAX: 800.556.5257 | WWW.THERMASOL.