INSTALLATION MANUAL LF RFID INTERROGATOR MODULE HTRM1100 VERSION 1.
Installation Manual Copyright 2019 by: LF RFID Interrogator HTRM1100 froschelectronics GmbH Moserhofgasse 60/1 8010 Graz Austria The content of this document and comments made in the operating instructions may be altered without previous notice. With this edition of the instruction manual all previous editions become void. This document and its content have been composed to the best of our knowledge.
Installation Manual LF RFID Interrogator HTRM1100 Contents 1 Revision History .............................................................................................................. 3 2 Introduction .................................................................................................................... 4 3 Product Overview ............................................................................................................ 4 4 Important Safety Instructions ...............
Installation Manual 1 LF RFID Interrogator HTRM1100 REVISION HISTORY Revision Date Description 1.0 April 2019 Initial Version 1.1 September 2019 7 Product Specification updated 1.2 February 2021 FCC labelling and Antenna installation updated froschelectronics GmbH Rev 1.
Installation Manual LF RFID Interrogator HTRM1100 2 INTRODUCTION The RFID reader module HTRM1100 is an OEM device and must be professionally installed. The final device user manual must not include installation instructions of the HTRM1100 module and antenna. This Installation Manual provides information to install the RFID-reader module and the antenna.
Installation Manual LF RFID Interrogator HTRM1100 Only use attachments and accessories specified by . Use FCC/CE certified power supply only. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way. The device may only be used for the intended purpose designed for by the manufacturer.
Installation Manual LF RFID Interrogator HTRM1100 5.4 LIMITED MODULE PROCEDURES As the HTRM1100 is not a “Limited module” the “Limited module procedures” are not applicable. 5.5 TRACE A NTENNA DESIGNS Since it is not intended to use trace antennas with the HTRM1100, this item is not applicable. 5.6 RF EXPOSURE CONSIDERATIONS SAR testing is not required for transmitters where a distance to the human body of less than 20 cm is not expected.
Installation Manual LF RFID Interrogator HTRM1100 Above information must also be included in the final device manual. 5.9 INFORMATION ON TEST MODES AND ADDITIONAL TESTING REQUIREMENTS FCC document “996369 D04 Module Integration Guide v02” give some suggestions for common technology types on how the host product manufacturer may operate their product during investigative measurements. The HTRM1100 is not operating in these common technology types and these investigative measurements are not applicable.
Installation Manual LF RFID Interrogator HTRM1100 The module must be mounted into a cabinet or housing. The enclosure must be at least IP22 rated when used indoors and IP44 rated when the unit is intended to be operated outdoors. If screwing is necessary in order to fix the module 4 spacers of thread size M3mm (UNC 4-40 or 6-32) must be used. Figure 2: Mounting holes of the module Use spacer bolts of minimum length 7mm (9/32 in) for mounting.
Installation Manual LF RFID Interrogator HTRM1100 The terminal block fits wires from 0.5 mm² - 3.3 mm² (20 AWG - 12 AWG). 6.5 A NTENNAS In order to comply with part 15 of the FCC and the CE regulations only magnetic loops with an enclosed area of not more than 0.375 sqm (A<= 0.375m²) and not less than 0.004 sqm (A>= 0.004m²) must be used and connected to the module. Only antennas which are manufactured or certified by freaquent must be used.
Installation Manual LF RFID Interrogator HTRM1100 7 HTRM1100 PRODUCT SPECIFICATION Electrical Specifications Operating Frequency Compliances Uplink Data Rate Downlink Data Rate Number of Antenna ports Range of Antenna Inductance tunable Minimum Dimensions of the Antenna-loop Maximum Dimensions of the Antenna-loop Operating Range Output Power Output Current Modulation Index Inputs Outputs Power Supply Power Consumption 134,2 kHz ISO11784/85, ISO 14223, ISO18000.
Installation Manual LF RFID Interrogator HTRM1100 8 COMPLIANCE INFORMATION STATEMENT Model: HTRM1100, Type: LF RFID Interrogator CE-Certification: When properly used this radio equipment conforms to the essential requirements of Article 3 and the other relevant provisions of the R&TTE Directive 1999/5/EC of March 99. Equipment Classification according to ETSI EN 300 330 and ETSI EN 301 489: Class 2 FCC ID: 2ACK5-HTRM1100 This device complies with Part 15 of the FCC Rules.