testoSaveris 2Probe User Manual testo Saveris 2Introduction testo Saveris 2 system is upgrading product basing on testo Saveris system. In original system, wireless probes transfer measurement data to Saveris base through local area network, testo professional software manages data and supply service on data record and monitor. In Saveris 2 system, data transfer from Internet basing on Qualcomm new Wi-Fitechnology, probes can communicate with the cloud through wireless router.
testo Saveris 2 Application Medicine production, quality inspection and storage monitor Building surrounding measurement and monitor Development, laboratory, hospital surrounding measurement and monitor Food cold chain measurement and monitor Plant production, transfer and storage measurement and monitor testoSaveris 2 Probes Testo Saveris has five Wi-Fi probes: T1, T2, T3, H1 and H2.
Saveris T2 can support two channel external temperature probe, can continuously measure and record surrounding temperature and transfer to cloud website. Saveris T2 passed EN12830 approval, can use in food industrial surrounding measurement and monitor. Saveris T3 support two channel TC probes, can continuously measure and record surrounding temperature and transfer to cloud website.
Saveris H1 has inside temperature sensor and humidity sensor, can continuously measure and record surrounding temperature and transfer to cloud website Saveris H2support external testo humidity probe, can continuously measure and record surrounding temperature and transfer to cloud website.
testo Saveris 2 Probe technical Data: type Saveris measurem ent One inside NTC Measurem ent range T1 -30…+50°C Saveris T2 Saveris T3 Saveris H1 Saveris H2 Two external NTC Two external TC One inside humidity One external humidity humidity“ 0… 100%RH humidity: 0…100%RH NTC: -30…+50°C NTC: -30…+70°C ±2% RH, ±2% RH, ±0,5 °C ±0,5 °C 0.1°C, 0.1%, 0.1Ctd °C 0.1°C, 0.1%, 0.
testo Saveris 2 Probes Specification: type Order number Operate temperate range Storage temperatur e range Saveris T1 0572 2001 Saveris T2 0572 2002 Saveris T3 0572 2003 Saveris H1 0572 2004 Saveris H2 0572 2005 -30 … +50 °C -30 … +50 °C -30 … +50 °C -30 … +50 °C -30 … +50 °C -40 … +70 °C -40 … +70 °C -40 … +70 °C -40 … +70 °C -40 … +70 °C 5s ~ 24hour (default setting 15 min) 5s ~ 24hour (default setting 15 min) 5s ~ 24hour (default setting 15 min) 5s ~ 24hour (default setting 15 min) 5
testo Saveris 2 Probes Instruction Manual Product description: ①device ②LED ③QR code(probe serial number, cloud website adderess) ④key ⑤wall holder ⑥USB communication cable ⑦lock First step Inserting batteries: To open the battery compartment, remove two screws on battery cover by screwdriver. Insert batteries (4x 1.5 V type AA). Observe the polarity! To close the battery compartment, tighten screws by screwdriver.
Probe Configuration Visit website:https://intl.saveris2.net/GoToProbe Enter log in page and input personal account and password Click and enter to Wi-Fi connecting page, click “Connect Wifi-logger”,input wireless router SSID and password to connect into internet 。 In connect successfully, icon will displayed on Saveris probe LCD.
Click “Probe” o enter configuration page. Set probe basic configuration, input probe number, name, location, measurement cycle, communication cycle, start time and etc.
Probe Management After probe configuration, probe list can be found in Saveris system, and also on-time measurement data, Wifi signal status, battery power status。 Click name of probe and enter probe detailed information page which show detailed measurement status of each channel. Click “configuration”, can enter configuration page to modify configuration of probe.
Measurement Data transfer After configuration finish, probe can start measurement and transfer data to cloud side. During data transferring,icon will be displayed on LCD. Customer can also scan QR code on front housing of Saveris probe to visit cloud.
FCC statements: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications or changes to this equipment.
Radiation Exposure Statement: This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Déclaration d'exposition aux radiations: Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies pour un environnement non contrôlé.