testoSaveris 2 User Manual testo Saveris 2Introduction testo Saveris 2 system is upgrading product basing on testo Saveris system. In original system, wireless probes transfer measurement data to Saveris base through local area network, testo professional software manages data and supply service on data record and monitor. In Saveris 2 system, data transfer from Internet basing on Qualcomm new Wi-Fitechnology, probes can communicate with the cloud through wireless router.
w w w w testo Saveris 2 Application ¾ Medicine production, quality inspection and storage monitor ¾ Building surrounding measurement and monitor ¾ Development, laboratory, hospital surrounding measurement and monitor ¾ Food cold chain measurement and monitor ¾ Plant production, transfer and storage measurement and monitor testoSaveris 2 Probes Testo Saveris has five Wi-Fi probes: T1, T2, T3, H1 and H2.
Saveris T2 can support two channel external temperature probe, can continuously measure and record surrounding temperature and transfer to cloud website. Saveris T2 passed EN12830 approval, can use in food industrial surrounding measurement and monitor. Saveris T3 support two channel TC probes, can continuously measure and record surrounding temperature and transfer to cloud website.
Saveris H1 has inside temperature sensor and humidity sensor, can continuously measure and record surrounding temperature and transfer to cloud website Saveris H2support external testo humidity probe, can continuously measure and record surrounding temperature and transfer to cloud website.
testo Saveris 2 Probe technical Data˖ type Saveris measurem ent One inside NTC Measurem ent range T1 -30…+50°C Saveris T2 Saveris T3 Saveris H1 Saveris H2 Two external NTC Two external TC One inside humidity One external humidity humidity“ 0… 100%RH humidity˖ 0…100%RH NTC: -30…+50°C NTC: -30…+70°C T type TC: -200…+400°C -50…+150 °C K type TC: -195…+1350° C J type TC: -100…+750°C ±0,5 °C ±0,5 °C ± (0,5 + 0.
resolution T90 response time 0.1°C 0.1°C 0.1°C(-200~99 9.9), others 1°C 40 minutes Up to external probe Up to external probe 0.1°C, 0.1%, 0.1Ctd °C 0.1°C, 0.1%, 0.
min) min) min) min) min) Data memory 10000 data per channel 10000 data per channel 10000 data per channel 10000 data per channel 10000 data per channel LCD display yes yes yes yes yes Battery life 4pcs L91 battery 2 years 4pcs L91 battery 2 years Norm EN12830 EN12830 ------ ------ ------ accessory GP AA battery Wall holder lock USB cable GP AA battery Wall holder lock USB cable GP AA battery Wall holder lock USB cable GP AA battery Wall holder lock USB cable GP AA battery Wall
device LED QR code˄probe serial number, cloud website adderess˅ key wall holder USB communication cable lock First step Inserting batteries: ¾ To open the battery compartment, remove two screws on battery cover by screwdriver. ¾ Insert batteries (4x 1.5 V type AA). Observe the polarity! ¾ To close the battery compartment, tighten screws by screwdriver. Probe Configuration ¾ Visit website˖https://intl.saveris2.
¾ Click and enter to Wi-Fi connecting page, click “Connect Wifi-logger”ˈinput wireless router SSID and password to connect into internet DŽ In connect successfullyˈ icon will displayed on Saveris probe LCD. ¾ Click “Probe” o enter configuration page. Set probe basic configuration, input probe number, name, location, measurement cycle, communication cycle, start time and etc.
Alarm Setting ¾ Click “Alarm” and enter alarm setting page, click“Alarm configuration”ˈset up alarm upper and lower limit value one by oneDŽ
Probe Management After probe configuration, probe list can be found in Saveris system, and also on-time measurement data, Wifi signal status, battery power statusDŽ ¾ Click name of probe and enter probe detailed information page which show detailed measurement status of each channel. Click “configuration”, can enter configuration page to modify configuration of probe.
Measurement Data transfer After configuration finish, probe can start measurement and transfer data to cloud side. During data transferringˈicon will be displayed on LCD. Customer can also scan QR code on front housing of Saveris probe to visit cloud. Question and Answers: * battery power<5%˖repalce batteries oooo * external probes not connected * real value out of measurement range Power is so low that no RF exposure calculation is needed.
FCC statements: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications or changes to this equipment.
L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnemen