Manual KeyReader Plus KeyReader Plus Manual KeyReader Plus TeraTron GmbH Manual_KeyReaderPlus.doc Page 1 of 12 Document Version 1.0 Date: 19.07.
Manual KeyReader Plus Document: Manual Bedatungsstation Project: 0211 Documenten Version: 1.0 Autor V 1.0 Name Frank Bajahr Datum: 19.07.2016 Tel. +49 2261 8082 133 Fax E-Mail Frank.bajahr@teratron.de Document status Draft Confidential public Release Organisation Version Date 19.07.2016 Attachments Auther Manual KeyReader Plus TeraTron GmbH Manual_KeyReaderPlus.doc Name Version V 1.0 Datum Change - first release - Name Frank Bajahr Document Page 2 of 12 Document Version 1.
Manual KeyReader Plus Index 1 Introduction ................................................................................................................................... 4 2 Mechanical .................................................................................................................................... 5 3 Driver Installation ..........................................................................................................................
Manual KeyReader Plus 1 Introduction The KeyReaderPlus is a portable Device which is capable of reading data stored in dedicated vehicle keys. Once the data have been read the data are transferred to a remote server. The transfer takes place via Wifi or the USB Interface. Delivery Content KeyReaderPlus Handheld USB-Cable The user(s) of these products are cautioned to only use accessories and peripherals approved, in advance, by MANUFACTURER.
Manual KeyReader Plus 2 Mechanical Status Key Reading Battery Status Server Connection On/Off/Factory Reset 3 Sliding Bar Micro-USB Driver Installation All required components will be installed by performing the Setup-Program on the target PC. During the Setup it is required to login as a local admin. System Requirements: Personal Computer with Windows 7, 8.1 oder 10 Eine freie USB-Schnittstelle Internet Browser, e.g.
Manual KeyReader Plus In order to charge the KeyReader Plus the USB-Interface should be capable to deliver at least 500mA. If this is not given charging has to be done with an appropriate USB-Charger. To install the required driver please start the KeyReaderPlus_Vx.x.x.x.exe. Select the language to proceed. Picture 1: select language Confirm with „Next“ Picture 2: Welcome Screen Manual KeyReader Plus TeraTron GmbH Manual_KeyReaderPlus.doc Page 6 of 12 Document Version 1.0 Date: 19.07.
Manual KeyReader Plus Confirm with „Install“ Pictuire 3: Confirmation Once the installation has been finished the last screen will prompt for “Finish” Manual KeyReader Plus TeraTron GmbH Manual_KeyReaderPlus.doc Page 7 of 12 Document Version 1.0 Date: 19.07.
Manual KeyReader Plus Picture 4: Completion Your Personal computer is prepared to work with the KeyReader Plus now. 4 Configuration of KeyReader Plus Connect the KeyReader Plus to an USB-Port of your PC. In case the KeyReader was off it will now automatically turn on and boot up. During the boot process the „Key” LED is flashing blue. The “Battery” LED is indicating the charge condition of the battery. If it is green no charging takes place. If yellow, charging is in grogress.
Manual KeyReader Plus Picture 5: Welcome screen The following system information are shown: KeyReader Plus Serial Number: serial number of the device Identifier KeyReader Plus: peronal name of device (can be configured.
Manual KeyReader Plus Battery charge cycles: no. of charging cycles WLAN Mac Adr: mac address of the Wifi-Interface WLAN Connected: Wifi connection status Login-Button: you have to login to configure the KeyReader Plus. Login name and passwort are configurable Default username / password: BMW / admin Find Me !: This button will activate an acoustic feedback of the device Factory Reset: sets the KeyReader Plus back to factory settings Ping to KAI IP : check the connection to the KAI server.
Manual KeyReader Plus At the Configuration page the system time is shown. If there is an active connection to the Internet the system time is set automatically. In case there is not Internet connection the system time can be set by hitting the “Set System Time” button. Identifier Key Reader Plus: name teh KeyReader Plus to your personal needs Web-Interface IP-Port: Port for this web interface.
Manual KeyReader Plus The time for reading a key might be different, based on the data content of the key. It should be in the range of 1 to 4 sec. Once the data have been read they will be transferd tot he KAI server. If the transmission is successful the reader will beep a third time and the LED in the middle will flash green for confirmation. In case thaer is no contection to the KAI server the LED will start flashing red (no Wifi connection) or yellow (server is not responding).
Canada, Industry Canada (IC) Notices This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause interference; and (2) This device must accept any interference, including interference that may cause undesired operation of the device. Canada, avis d'Industry Canada (IC) Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence.