Replace FaST system orifice (Red)

IB 340782 (02--2006) 1
No. 340782
Machine: T3, T7,
2001HD
Published: 02--2006
Rev. 01
INSTRUCTION BULLETIN
NOTE: DO NOT DISCARD the Parts List from the Instruction Bulletin. Place the
Parts List in the appropriate place in the machine manual for future
reference. Retaining the Parts List will make it easier to reorder
individual p arts and will save th e cost of ordering an entire kit.
NOTE:Numbers in parenthesis ( ) are reference numbers for parts listed in Bill of Materials.
Installation instructions for kit number 9001488, 9001489, 9001490
SYNOPSIS:
This kit contains the parts needed to replace the FaST system orifice on T3, T7, and 2001HD
machines.
Please follow step-by-step instructions.
SPECIAL TOOLS / CONSIDERATIONS: NONE
(Estimated time to complete: 1 hour)
PREPARATIO N:
1. Park the machine on a clean level surface,
completely lower the scrubber head and
squeegees, turn off the machine, and remove
the key.
FOR SAFETY: Before leaving or servicing
machine, stop on level surface, turn off
machine, and remove key.
INSTALLATION:
NOTE: Note position/orientation of all hoses
attached to the FaST injector assembly before
removing the FaST injector assembly from the
machine. All hoses must be positioned/oriented as
they were before disassembly when the FaST
injector assembly is later reinstalled onto the
machine.
1. Remove the FaST injector assembly from the
holder clip. Do
Not disconnect any hoses from
the FaST injector assembly. Refer to Fig. 1.
NOTE: The photograph in Fig.1 shows where the
FaST injector assembly and holder clip are
located on the T7/SSR machines. Refer to T3 and
2001HD parts manuals for locations of these parts
on the T3 and 2001HD machines.
FaST Injector
Assembl y
Holder Clip
FIG. 1
2. T wist the plastic fitting from the FaST injector
assembly. Refer to Fig. 2.
3. Remove the filter screen from inside the
plastic fitting. Discard the filter screen. Refer
to Fig. 2.
4. Remove the orifice plate and flat washer from
inside the FaST injector assembly. Discard the
orifice plate and flat washer. Refer to Fig. 2.
5. Insert the new filter screen (2) into the plastic
fitting. Refer to Fig. 2.
6. Insert the new orifice washer (1) into the
FaST injector assembly. Refer to Fig. 2.

Summary of content (2 pages)