MBS USER AND INSTALLATION MANUAL PRODUCT: CODE: MBS D148X01PT_DDS06 VERSION: 04 CLASSIFICATION: REVISION: DATE: 00 General information 14-Nov-2014 Internal document DOCUMENT MAINTENANCE THIS DOCUMENT HAS 17 PAGES EDIT. DATE AUTHOR 1.0 05-Oct-2011 Javier Córdova 2.0 02-May-2012 Javier Córdova 3.0 19-Dec-2012 A. González 4.0 14-Nov-2014 F.Rivas DESCRIPTION First edition. Changes in section 4. Document code and minor editorial changes.
MBS USER AND INSTALLATION MANUAL Code: D148X01PT_DDS06 Date: 14-Nov-2014 Page: 2 of 41 PowerTrunk Inc. is the subsidiary of Teltronic S.A.U. responsible for business development, distribution and customer support for Teltronic’s Land Mobile Radio products in North America. The company is headquartered in New York City. Teltronic S.A.U. distributes the same products for Land Mobile Radio under different trademarks and brand names in other regions of the world.
MBS USER AND INSTALLATION MANUAL Code: D148X01PT_DDS06 Date: 14-Nov-2014 Page: 3 of 41 CONTENTS: 1. INTRODUCTION ......................................................................................................... 4 2. UNPACKING AND CHECKING .................................................................................. 4 3. PREVIOUS CONSIDERATIONS................................................................................. 4 4.
MBS USER AND INSTALLATION MANUAL Code: D148X01PT_DDS06 Date: 14-Nov-2014 Page: 4 of 41 1. INTRODUCTION The MBS Units are the outdoor modules that make up a Mast Mounted Base Station (MBS). They are independent units that can be interconnected with each other to increase the base station capacity. A MBS consists of a maximum of two MBS Units. This manual is common to all the equipment models, including all their options and accessories.
MBS USER AND INSTALLATION MANUAL Code: D148X01PT_DDS06 Date: 14-Nov-2014 Page: 5 of 41 4. LABELLING AND INFORMATION ON SAFETY AND ELECTROMAGNETIC COMPATIBILITY The equipment is supplied with an identification label where the model, the IC Certificate number and the FCC ID are displayed depending on the frequency work band. The equipment has been designed to fulfil the applicable compliance regulations.
MBS USER AND INSTALLATION MANUAL Code: D148X01PT_DDS06 Date: 14-Nov-2014 Page: 6 of 41 The following labels will be placed in conspicuous view on the MBS Unit: 01.01.00/1 Rev.1 q Most electronic equipment is susceptible to electromagnetic interference if it is not duly protected. If the MBS Unit is placed near unprotected electronic devices, they may malfunction. q The MBS Unit must not transmit without its antenna connected.
MBS USER AND INSTALLATION MANUAL Code: D148X01PT_DDS06 Date: 14-Nov-2014 Page: 7 of 41 4.1.
MBS USER AND INSTALLATION MANUAL Code: D148X01PT_DDS06 Date: 14-Nov-2014 Page: 8 of 41 4.2. UL / SAFETY CERTIFICATIONS The cabinet is UL certified, and complies with the requirements for electronic devices to minimise risks such as fire, electric shocks or injuries to the operator that may be caused in operation.
MBS USER AND INSTALLATION MANUAL EN 60068-2-64 * No functional: • Duration: 30 minutes by axe • 5-20 Hz. ASD: 1 m2/s3. • 20-200 Hz. ASD; - 3dB/oct EN 60068-2-6 * No functional: • Duration: 5 sweep by axe • 5-9 Hz. Displacement 1.2 mm. • 9-200 Hz. Acceleration 4 m/s2 UNE-EN 60598 * Vibration type: Sine swept * Frequency range: From 10 to 55 Hz * Amplitude (peak): • 10 Hz Amplitude (peak): 1.4 mm • 38 Hz Amplitude (peak): 20 m/s2 • 55 Hz Amplitude (peak): 20 m/s2 * Number of axes: 3 axes * Swept ratio: 1 Oct.
MBS USER AND INSTALLATION MANUAL Code: D148X01PT_DDS06 Date: 14-Nov-2014 MIL_STD-810G 514.6, Test procedure I, Vibration. Category 4, table C-VI C3 (Figure 514,6 C-3) MIL-STD-810G 516.6 Test procedure I and III, Shock. 20 g 11 ms, half sinus 01.01.00/1 Rev.
MBS USER AND INSTALLATION MANUAL Code: D148X01PT_DDS06 Date: 14-Nov-2014 Page: 11 of 41 5. EQUIPMENT DESCRIPTION 5.1. VIEW 5 1 4 3 Male panel connector 2 2 3 Female cable connector 1 01.01.00/1 Rev.
MBS USER AND INSTALLATION MANUAL Code: D148X01PT_DDS06 Date: 14-Nov-2014 Page: 12 of 41 5.2. CONNECTORS · 1.- Terminal with the following meaning depending on the MBS Unit Power option: - AC MBS Units: Neutral contact (N). - DC MBS Units: Negative contact (-). · 2.- Terminal with the following meaning depending on the MBS Unit Power option: - AC MBS Units: Line contact (L). - DC MBS Units: Positive contact (+). · 3.- Power supply Earth contact. · 4.- Pressure equalizer. · 5.
MBS USER AND INSTALLATION MANUAL Code: D148X01PT_DDS06 Date: 14-Nov-2014 Page: 13 of 41 Note: POWER_IN and POWER_OUT connectors have a coding key to avoid wrong connections; on the following table is showed the location of this coding key depending on the MBS Unit power supply option. External view of power supply panel connector AC Power Supply DC Power Supply Note: The amount of power delivered by both PoE and PoE/ETH connectors to the radio links can not exceed 35 W in total. 5.3.
MBS USER AND INSTALLATION MANUAL Code: D148X01PT_DDS06 Date: 14-Nov-2014 Page: 14 of 41 5.4. DIMENSIONS 6. INSTALLATION GUIDE The following recommendations must be followed before powering on the MBS Unit module. Next diagram shows the steps to be followed to carry out the installation: 01.01.00/1 Rev.
MBS USER AND INSTALLATION MANUAL Code: D148X01PT_DDS06 Date: 14-Nov-2014 Verification of the necessary equipment Basic Pre-Configuration Final location installation Final Configuration/Verification 01.01.00/1 Rev.
MBS USER AND INSTALLATION MANUAL Code: D148X01PT_DDS06 Date: 14-Nov-2014 Page: 16 of 41 6.1. NECESSARY EQUIPMENT Make sure you have the necessary equipment depending on the configuration to install. If any of the elements necessary to carry out the installation process described in this manual, were lost or damaged, contact your supplier and / or installer. Necessary equipment Element MBS Unit Code D148x01 Comments “x” varies depending on band.
MBS USER AND INSTALLATION MANUAL Code: D148X01PT_DDS06 Date: 14-Nov-2014 Page: 17 of 41 Additional equipment to be considered for installation Element Comments Cable to power the MBS See features in external power connection section. One power Unit. supply cable connector is supplied with the MBS Unit. Ethernet cable to connect See features in Ethernet connection section. One Ethernet PoE radio links cable connector is supplied with the MBS Unit. Antenna coaxial cable and antenna.
MBS USER AND INSTALLATION MANUAL Code: D148X01PT_DDS06 Date: 14-Nov-2014 Page: 18 of 41 6.2. BASIC PRE-CONFIGURATION Before connecting the MBS Unit to the infrastructure it should have the IP address correctly configured in order to have remote access once it is connected (to set the IP address, see the configuration chapter (F067220) in technical manual). Steps: · Apply power supply to the MBS through its POWER_IN connector. · Wait 3 minutes until the MBS Unit initializes.
MBS USER AND INSTALLATION MANUAL Code: D148X01PT_DDS06 Date: 14-Nov-2014 Page: 19 of 41 6.3. INSTALLATION The MBS has been designed to be mounted on both mast/pole and wall. This chapter provides the necessary steps to be followed for a right MBS Unit installation. At least two people are required to carry out the installation of a MBS Unit on a mast/pole.
MBS USER AND INSTALLATION MANUAL 6.3.1. Code: D148X01PT_DDS06 Date: 14-Nov-2014 Page: 20 of 41 MAST/POLE INSTALLATION The different section types of mast/pole where the MBS Unit can be mounted are the following ones: q Circular section: Diameter from 30 mm to 130 mm. q Square section: From 30 mm x30 mm to 85 mm x85 mm. q L section: From 30 mm x30 mm to 110 mm x110 mm.
MBS USER AND INSTALLATION MANUAL Code: D148X01PT_DDS06 Date: 14-Nov-2014 Page: 21 of 41 The brackets should be installed tight enough to support the MBS Unit without causing deformation of the mast/pole or areas of corrosion. Once mounted in its definitive location, if the vandal resistant kit is available, it will prevent the access / disassembly not authorized.
MBS USER AND INSTALLATION MANUAL Code: D148X01PT_DDS06 Date: 14-Nov-2014 Page: 22 of 41 Steps to install a MBS on a mast/pole: 1) Place the MBS Unit bracket on the mast/pole as follows. Note: Handle the MBS Unit bracket with care if it rests on the floor. Place some protection underneath to prevent scratches on the surface.
MBS USER AND INSTALLATION MANUAL Code: D148X01PT_DDS06 Date: 14-Nov-2014 Page: 23 of 41 2) Place MBS Unit on the bracket as follows. a) Raise the MBS Unit to the position where the bracket is placed on the mast/pole and hang it on the bracket, tilting slightly to match the bracket guides as indicated in the following figure: 01.01.00/1 Rev.
MBS USER AND INSTALLATION MANUAL Code: D148X01PT_DDS06 Date: 14-Nov-2014 Page: 24 of 41 b) Put the bolts of the MBS Unit and washers to the bracket with a 17 mm wrench and 15 Nm torque. Note: If anti-vandal kit is available (D014000), lateral bolts should be placed after mounting the anti-vandal kit. 3) Make the necessary cable connections as described in the connections section in this guide. 01.01.00/1 Rev.
MBS USER AND INSTALLATION MANUAL 6.3.2. Code: D148X01PT_DDS06 Date: 14-Nov-2014 Page: 25 of 41 WALL INSTALLATION To install the MBS Unit on a wall, make the following steps: 1) Mark the position of the holes using the bracket as a template itself with the help of a level. Note: To ensure proper ventilation there must be at least 700 mm clearance above and below each MBS Unit. There must also be a minimum distance of 300 mm free on both sides of the MBS Unit.
MBS USER AND INSTALLATION MANUAL Code: D148X01PT_DDS06 Date: 14-Nov-2014 Page: 26 of 41 3) Place the bracket over the rawlplug and insert the bolts and washers. Finally screw them with a 17 mm wrench and 15 Nm torque. 4) Place the MBS Unit on the bracket as follows. a) Raise the MBS Unit to the position where the bracket is placed and hang it on the bracket, tilting slightly to match the anchor guides as indicated in the following figure: 01.01.00/1 Rev.
MBS USER AND INSTALLATION MANUAL Code: D148X01PT_DDS06 Date: 14-Nov-2014 Page: 27 of 41 b) Put the bolts of the MBS Unit and washers to the bracket with a 17 mm wrench and 15 Nm torque. The order is bolt + grower washer + plain washer. Note: If anti-vandal kit is available (D014000), lateral bolts should be placed after mounting the anti-vandal kit. 5) Make the necessary cable connections as described in the connections section in this guide. 01.01.00/1 Rev.
MBS USER AND INSTALLATION MANUAL 6.3.3. Code: D148X01PT_DDS06 Date: 14-Nov-2014 Page: 28 of 41 ANTI-VANDAL KIT INSTALLATION The anti-vandal kit for MBS Unit is an optional accessory (D014000). Either the MBS Unit is mounted on a mast/pole or on a wall, the anti-vandal kit, is performed as follows. Take into account that the installation of the ant-vandal kit should be done once you have completed the wiring connections of the MBS Unit.
MBS USER AND INSTALLATION MANUAL - Code: D148X01PT_DDS06 Date: 14-Nov-2014 Page: 29 of 41 Place the padlock and screw the attachment bolt to the bracket with a 17 mm wrench and 15 Nm torque. 01.01.00/1 Rev.
MBS USER AND INSTALLATION MANUAL 6.3.4. Code: D148X01PT_DDS06 Date: 14-Nov-2014 Page: 30 of 41 CONNECTIONS This section shows the connections to be made and the characteristics of the material to be used. The MBS Unit is a weather-protected device once the equipment has been installed in its final location; make sure that there is no MBS Unit connector without plug or cable connected.
MBS USER AND INSTALLATION MANUAL 6.3.4.1. Code: D148X01PT_DDS06 Date: 14-Nov-2014 SUPPORTED CONFIGURATIONS a) ONE MBS UNIT WITHOUT DIVERSITY IN RECEPTION The connections are the following ones: Power supply 220/110 VAC or 24 VDC. q From ANT connector to the antenna. q Connection with radio link through PoE connector. q Maintenance through PoE/ETH N or ETH connector. 01.01.00/1 Rev.
MBS USER AND INSTALLATION MANUAL Code: D148X01PT_DDS06 Date: 14-Nov-2014 b) ONE MBS UNIT WITH DIVERSITY 2 IN RECEPTION The connections are the following ones: Power supply: 220/110 VAC ó 24 VDC. q From ANT connector to the first antenna. q From DIV IN connector to the second antenna. q Connection with the radio link through PoE connector. q Maintenance through PoE/ETH or ETH connector. 01.01.00/1 Rev.
MBS USER AND INSTALLATION MANUAL Code: D148X01PT_DDS06 Date: 14-Nov-2014 Page: 33 of 41 c) TWO MBS UNIT WITH DIVERSITY 2 IN RECEPTION The connections are the following ones: Power supply for the MBS Unit 1: 220/110 VAC or 24 VDC. q From ANT connector of the MBS Unit 1 to the first antenna. q From ANT connector of the MBS Unit 2 to the second antenna. q Connection with the radio links through PoE connector of both MBS Units.
MBS USER AND INSTALLATION MANUAL 6.3.4.2. Code: D148X01PT_DDS06 Date: 14-Nov-2014 Page: 34 of 41 CONNECTION OF THE EXTERNAL POWER SUPPLY Check that the power supply source and/or the battery to be used are adapted to the type of MBS Unit (AC/DC) and meets the voltage and current requirements necessary to supply the equipment. a) MBS Unit with AC power supply source: q Nominal voltage: 110/220 VAC (Range: from 94 to 264 VAC).
MBS USER AND INSTALLATION MANUAL Code: D148X01PT_DDS06 Date: 14-Nov-2014 Page: 35 of 41 § Fix each wire tightening each pin from the front side with a hexagonal screwdriver (Allen number 2). § Push the insert back into the hood/housing. § Fix the assembly tightening the top locking screw and tightening the cable gland nut on the back of the hood/housing. b) MBS Unit with DC power supply source: q Nominal voltage: 24 VDC (Range: from 21.6 to 31.2 VDC).
MBS USER AND INSTALLATION MANUAL q Code: D148X01PT_DDS06 Date: 14-Nov-2014 Page: 36 of 41 Ensure that the connection is made in the correct way (Positive, Negative and Earth) following the next steps: § Strip cable and wires (stripping length 8 mm - 9 mm). 8-9mm NOTE: The Earth cable must be 2 mm longer. § Push the cable through the cable gland and the hood/housing and insert the wires into the insert respecting the correct polarity. Earth (PE) Negative (-) Positive (+) 01.01.00/1 Rev.
MBS USER AND INSTALLATION MANUAL § Code: D148X01PT_DDS06 Date: 14-Nov-2014 Page: 37 of 41 Fix the assembly tightening the top locking screw and tightening the cable gland nut on the back of the hood/housing. c) In both cases: q The power supply cable to the MBS Unit must be provided by the installer with the proper power supply connector adapted for the connection to the electrical network or to a 24 VDC source q Ensure that the earth connection is made.
MBS USER AND INSTALLATION MANUAL Code: D148X01PT_DDS06 Date: 14-Nov-2014 Page: 38 of 41 q In installations with diversity, the greatest gain is achieved by placing the antennas on the same horizontal plane with a minimum distance of 5.5 m between them. q Measure the ROE of the installation. Never accept a ROE greater than 2. 6.3.4.4. q EXTERNAL ETHERNET CONNECTION The Ethernet cable connector, to connect the MBS Unit with the radio link (PoE), is supplied with every MBS Unit.
MBS USER AND INSTALLATION MANUAL 6.3.4.5. Code: D148X01PT_DDS06 Date: 14-Nov-2014 Page: 39 of 41 CONNECTION BETWEEN TWO MBS UNITS To connect two MBS Units you must have the interconnection kit for additional carrier (Cod. D014001). This is obtained as an independent accessory. Apart from the power wiring, antennas and radio links to connect as indicated in the section of supported configurations, it should be considered the use of interconnection kit between the two Units MBS, as indicated bellow.
MBS USER AND INSTALLATION MANUAL Code: D148X01PT_DDS06 Date: 14-Nov-2014 Page: 40 of 41 7. START UP/CONFIGURATION/VERIFICATION IMPORTANT: Ensure that the power supply of the MBS Unit is the proper one before switch it on; an erroneous power supply can cause damages in the equipment. Every MBS Unit has in its labelling the diverse options that it offers.
MBS USER AND INSTALLATION MANUAL Code: D148X01PT_DDS06 Date: 14-Nov-2014 Page: 41 of 41 8. INCIDENTS The MBS Unit must be repaired by authorized technical personnel only. There will not be performed any repair of the MBS Unit and it will have to be sent to factory except for the change of the pressure equalizer or the overvoltage protections. 8.1. INTERFERENCE AT MBS UNIT This alarm is monitored in the NEBULA (NMS) management and configuration module.