Telrad CPE12000 User Manual Telrad CPE-12000U-PRO-1D-5.x-Conn. User Manual CPE User Manual V1.
Telrad CPE12000 User Manual Index INDEX ......................................................................................................................................................................2 NOTE .......................................................................................................................................................................4 1. PRODUCT OVERVIEW .............................................................................................................
Telrad CPE12000 User Manual 5.6.2 Iperf .............................................................................................................................................................22 5.6.3 Traceroute ...................................................................................................................................................23 6. PRODUCT SHIPPING PACKAGE .....................................................................................................................
Telrad CPE12000 User Manual Note The content of this User Manual has been made as accurate as possible. However, due to continual product improvements, specifications and other information are subject to change without notice. This device must be installed by professional installer. Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules.
Telrad CPE12000 User Manual Prerequisite Skills and Knowledge To use this document effectively, you should have a working knowledge of Local Area Networking (LAN) concepts and wireless Internet access infrastructures. In addition, you should be familiar with the following: ● Hardware installers should have a working knowledge of basic electronics and mechanical assembly, and should understand related local building codes.
Telrad CPE12000 User Manual 1. Product Overview This CPE supports LTE air interface with popular operating systems like Windows, Linux and Mac. Once you have identified the place for CPE, insert USIM card supplied by your service provider at the appropriate place, plug in the adapter in the AC socket and DC in the power port of CPE. Power On device, after few minutes the CPE should attach itself to the LTE network. It is as simple as that.
Telrad CPE12000 User Manual Water & Dust Protection Operating Temperature Humidity IP67 -40 to +60 ºC 0 to 95% 1.3. Electrical and Environmental Specification Item Specification Operating Temperature Operating Humidity Lightning protection ability -40ºC to +60ºC 0 to 95% Common mode 6kV /Differential mode1.5kV 2. Product Package Items ODU unit Mounting Kit User Manual Installation Guide Charger CPE User Manual V1.
Telrad CPE12000 User Manual 3. Mechanical Specifications Figure 1: CPE12000 Bottom View Item Size Color LED RJ45 connector USIM Interface CPE User Manual V1.
Telrad CPE12000 User Manual LED Indicators LED name Location Color LED List Blue PWR Blue Blue ETH SIM RF Status 2 RF Status 3 RF Status 4 RF Status 5 CPE User Manual V1.
Telrad CPE12000 User Manual 4. Login Open your Web browser and enter 192.168.254.251, Default is username / passwords are: admin / admin for end-user Figure 4-1 Login 5. Home page 5.1 LTE There are 6 function on this page, they are “Overview”, ”ND & S” , ”PLMN Selection”, “eNB Settings”, “PDNs Settings”, “PIN Management” Figure 5-1 LTE CPE User Manual V1.
Telrad CPE12000 User Manual 5.1.1 Overview There are more LTE information on this page, they are “Serial Number”, “IMEI”, “IMSI”, “Supported Band”, “Firmware version” and so on. Figure 5-1-1 Overview 5.1.2 ND&S On this page include “Uplink QAM64”, “Scan Mode” and “Band” CPE User Manual V1.
Telrad CPE12000 User Manual Figure 5-1-2 ND&S Uplink QAM64: Enable/Disable Scan Mode: Full band/Dedicated Earfcn Band: Supported Band selection (Default band is 46) 5.1.3 PLMN Selection On this page, include “Network Mode “and “Allow Roaming” Figure5-1-3 PLMN Selection Network Mode: there are two modes Nomadic, Mobile Nomadic: modified scanning eNB selection. Mobile: regular scanning PLMN/ eNB selection.
Telrad CPE12000 User Manual Figure5-1-4 eNB Settings Preferred eNB List: Enable/ disable “preferred” selection checkbox.
Telrad CPE12000 User Manual “ ” button. Figure 5-1-5 Bearer Settings 5.1.6 PIN Management From this page, you can see the USIM card status and PIN status. The default PIN status is disabled; you can input the correct PIN to enable the PIN function. The maximum PIN attempts are 3, otherwise you must enter PUK to reset the PIN code. The USIM will be invalid after the unsuccessful attempts for 10 times. Figure 5-1-6 PIN Management 5.2 Network 5.2.
Telrad CPE12000 User Manual Figure 5-2-1-1 Overview 5.2.2 Internet On this page, include “Connection Mode”, “NAT”, “MGMT and Date Interface”, and “MTU”. Figure 5-2-2-1 Internet Connection Mode: Route/NAT, L2 Bridge(GRE), L3 Bridge NAT: Default Enable MGMT and Date Interface: Combine/ Separate 5.2.5 LAN On this page, include “LAN Reset”, “Device IP” and “DHCP” CPE User Manual V1.
Telrad CPE12000 User Manual Figure 5-2-3-1 LAN LAN Reset: Restore of LAN default setting. Duplex: Autot/Full/Half Max Bit Rate: 10Mbps/100Mbps/1000Mbps Local IP Address : Enter the IP address of your router (factory default: 192.168.254.251). Subnet Mask:An address code that determines the size of the network. Normally use 255.255.255.0 as the subnet mask. DHCP:Default Enable DHCP Address Allocation: Specify an IP address for the DHCP server to start and end with when assigning IP address.
Telrad CPE12000 User Manual Figure 5-2-4-1 VPN 5.2.7 QoS On this page, include “DSCP Configuration” and “TOS Configuration”, you can change QoS setting by manual. Figure 5-2-5-1 QoS Data Traffic DSCP: Default value is 0. The range is 0~63. Management Data DSCP: Default value is 6. The range is 0~63. Data Traffic TOS: Default value is 0. The range is 0~255. Management Data TOS: Default value is 0. The range is 0~255. 5.3Applications 5.3.
Telrad CPE12000 User Manual Figure 5-3-1-1 Port Forwarding 5.3.2 DMZ From this page, you can configure a De-militarized Zone (DMZ) to separate internal network and Internet. Figure 5-3-2-1 DMZ DMZ Enable: Default value is Disable DMZ Host IP address: The IP address of your PC.
Telrad CPE12000 User Manual 5.4 Management 5.4.1 Device Management On this page, include “ Allow ping from WAN ”, “Telnet Service”, “ SSH Service”, “ Access Control ”and “ HTTPs From WAN”. Figure 5-4-1-1 Device Management 5.4.2 TR069 On this page, include “TR069 Enable” and “TR069 Configuration” Figure 5-4-2-1 TR069 CPE User Manual V1.
Telrad CPE12000 User Manual TR069: Default value is Enable ACS Interface: Default value is “lte0pdn0” ACS Port: Default value is “7547” ACS URL: Default “ http://cpe.tr69.management.
Telrad CPE12000 User Manual new password. Figure 5-5-1-1 Password 5.5.2 NTP On this page, include “NTP Server”, “ Specify NTP Server”, “ Alternate NTP Server” and “NTP Synchronization”, you can change setting by manual. Figure5-5-2-1 NTP Settings 5.5.3 Configuration Management Clicking the “Export” button, the current settings will be saved as a data file to the local PC. You can restore the device configuration from the files that you saved. Figure 5-5-3-1 Config Management CPE User Manual V1.
Telrad CPE12000 User Manual 5.5.4 Firmware Update On this page, you can upgrade the current Router version from the local PC. 30s is needed to complete the whole upgrade process, and then the device will reboot automatically. Figure 5-5-4-1 Firmware Update 5.6 Maintenance 5.6.1 Ping On this page, you can ping IP address by manual. Figure 5-6-1-1 ping 5.6.2 Iperf On this page, you can use the page of “iperf”, test throughput function. CPE User Manual V1.
Telrad CPE12000 User Manual Figure 5-6-2-1 Iperf Status: Default value is “Enable” Server Address: Default value is “8.8.8.8” Server Port: Default value is “5001”, the range is 1024~65535 Management Port: Default value is “5001”, the range is 1024~65535 Measurement Time: Default value is “60” Protocol Type: TCP/UDP Windows size: Default value is “256” TCP Client Number: Default value is “1”, the range is 1~10 5.6.3 Traceroute On this page, you can Trace IP address by manual.
Telrad CPE12000 User Manual 6. Product Shipping Package 1. Main Lable On Main Label, you can see IMEI/MAC/SN on it. Figure 1: Main Label 2. Gift Label On Main Label, you can see IMEI/MAC/SN on it. Figure 1: Gift Label CPE User Manual V1.
Telrad CPE12000 User Manual 7. Revision History Author Revision Changes Date Fhan 1.0 Create Draft 2018-12-20 Fhan 1.1 Add customer issue 2019-01-08 Fhan 1.2 Add customer issue 2019-01-10 Telrad 1.3 Modifications 2019-01-13 XPpan 1.4 Add customer issue 2019-01-23 JiaWang 1.5 Change menu 2019-06-17 CPE User Manual V1.