COMMERCIAL IN CONFIDENCE Technical Note Subject: User Manual and instructions for Telecell 2 - N.
Telensa Telecell 2 User Manual N.
Contents CONTENTS ................................................................................................................................................................ 3 1 OPERATIONAL SAFETY NOTICES ............................................................................................................ 4 2 PRODUCT FUNCTION ................................................................................................................................... 4 3 TELECELL VARIANTS .............
1 Operational Safety Notices Installer Installers must be suitably trained and qualified for electrical work, according to the laws and local codes for the locality and country where the unit will be installed. This unit must only be installed by personnel that have been trained by Telensa or their representatives to carry out this work.
4.2 Notes on dimming control outputs These notes apply to products with the integrated dimming control function: Suitable for use with dimmable ballasts with an isolated or non-isolated control input DALI or 0-10V control mode is auto-selected by the telecell by communicating with the connected ballast.
5.4 Installation logging The telecell ID number, the OSID, is bar coded and located underside the unit. This OSID must be recorded with the ID or geographic co-ordinates of the lamp under control and recorded in the CMS database. There are a number of different methods to achieve this and installers will be trained with the appropriate method for their system. Fig 1: Example NEMA socket showing alignment 6 Telecell Connection Diagrams Refer to figures 2 and 3 overleaf.
Live in Telecell Live out Lamp Neutral Live in Neutral Lamp Lamp Figure 2: Wiring Diagram for Telecell - No Dimming Function 6LT071 01 QP4016 07- Tech Note Template 20 May 2016 Lamp Ballast
Live in Telecell Neutral Dimmer control Live out Ctrl 1 Lamp Ctrl 2 Live in Dimmable Ballast Neutral Lamp Lamp Figure 3: Wiring Diagram for Integral Dimming Control Telecell 6LT071 01 QP4016 07- Tech Note Template 20 May 2016
7 Notices for products operated in the USA & Canada This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to Part 15 of FCC rules.