e2-Live Home Automation iPower Smart Power Socket PS-30X Instruction Manual Edit by Shine Lo 1
e2-Live Home Automation iPower Specifications Hardware e2-Live RF Tx/Rx 2 way module Frequency:433.92MHz +/- 150KHz Digital ID coding (0000~9999) Received / Emit distances : open space 60 meters Specifications of loading Power overload protection of recovery fuse x1 3 circuits ON/OFF totally loading 110V 1650W 220V 1800W RS-485 communication,0.
e2-Live Home Automation Hardware All circuits can manual ON/OFF switch, with HA power detection of RP-20, please keep the status power on with blue LED extinguish) Appearances Used for two way control or inquiry communic ation via RS-485 Overload recovery fuse protection, it will shut down automatically to protect iPower itself, and will return to normal situation when overload was removed Edit by Shine Lo 3 circuits total loading are 110V 1650W 220V 1800W While overload happened, iPower will shu
e2-Live Home Automation Accessary Power line Note: Special specifications, please with this power line for ipower using in order to make sure correct operations.
e2-Live Home Automation Setting iPower Set up before using : ID & position of remote button Main function is to be controlled wirelessly by all kind of remote controller of e2-Live. General functions : For connected device, which does not need to know the status of power, or judge the function.
e2-Live Home Automation Using the RC-07 remote control to set the first circuit of iPower Second District, No. 5 position, to accept the "All off" control set 1. Press the button and hold iPower first circuit (1) 2. Setting stick or paper clip poke the tact switch in (2) Setting stick or paper clip poke the tact switch in (2) (2) Red LED light on (1) Press and hold (3) 3. Press RC-07 (3) 4. Press RC-07 (4) (5),to accept “All off” control 5.
e2-Live Home Automation Link connect RP-20, when scenario is been executed, it will detect the power status of your appliances For appliances, used with RP-20 in scenario control, detect the real ON or OFF situation to ensure the accuracy of scenario performance.. Specifies the appliance's remote position setting for number 1 ~ 7 of fifth zone.
e2-Live Home Automation 3. Plug in the device corresponding position, adjust to detect the right current consumption when power on and off. Appliances and iPower control location setting is complete and correct detection from the current adjustment, to make sure correct linking function be executed from RP-20.. Specifies light fifth zone 1-7 for power detection position. For example: 1. Connect to PC with RP-20 via USB, open RP-20 software, checking COM connection. 2.
e2-Live Home Automation Control Validation/ Light & Curtain Plug in the above appliance and power on, blue LED extinguish (圖一) (3) (4) (5) Accept all lights off function Not accept all lights off function (圖一) AMP Power → Zone 5 No.1 light TV Power → Zone 5 No.
e2-Live Home Automation STB Power → Zone 5 No.3 DVD Power → Zone 5 No.4 CD Power → Zone 5 No.5 CATV Power → Zone 5 No.6 AUX Power → Zone 5 No.7 iPower power status detection & RP-20 scenario editing setting In scenario edit setting graphic, for TV/CD/DVD/AMP/STB/CATV/A/C, all of these 7 appliances can select power current detectionfunction. Always ON : in scenario function been executed, RP-20 will checking the power current status. If TV is power ON, RP-20 will not send out action.
e2-Live Home Automation Power current detection setting : Step 1 Plug in appliance in iPower socket, Press button to provide power to this device (blue LED light off) Step 2 Turn on the device power (in operation mode, not in standby mode) Red LED light on : the device is power off Red LED light off : the device is power on Step 3 Use flat head screw driver to adjust red LED light on. Then turn the knob back let LED just light off.
FCC WARNING This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE 1: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.