Name & List of Parts
1. TC2520C MAIN UNIT *1 7. 2P WIRE FOR KILLER *1
2. 4 BUTTON TRANSMITTER *1 8. LED INDICATOR *1
3. SHOCK SENSOR *1 (built-in main unit) 9. PIN SWITCH *2
4. 1 TONE SIREN *1 10. MANUAL *1
5. 8P HARNESS *1 11. SCREW PACK *1
6. 6P HARNESS *1 12. OVERRIDE SWITCH *1
Changing TX battery
After changing the battery on the code-learned Transmitter, please press any key twice continuously for main
unit recognizing the TX.
Instruction:
1. Definition of Transmitter’s Buttons:
y Button 1
yy Button 2
Button 1:
a. Arming.
b. Silent Arming (Press the button continuously 1.5sec)
c. Remote door locking.
Buttons 2:
a. Disarming.
b. Silent disarming (Press the button continuously 1.5sec)
c. Remote door unlocking
d. 2 stage disarming while alarm’s triggered
Button 1+2: Car searching
This remote control transmitter provides 2 billions of digital codes with an operative range up to 100 feet,
(The operative range will be shorten when system is interrupted or out of power) and also contains
Anti-Duplicating & Anti Scanning which is the most secure tool.
2. Micro-Code Learning:
Please follow below procedures of code-learning, when renewing or adding more transmitters
a . Turn the car key to the “ON” position, close the car door.
b. Make sure all doors are in close position. Press the override switch one time, siren wails and indicator
(parking) light blink once in 10 seconds then press override switch two times continuously.
c. Siren wails 2 times, LED light flashes rapidly. (Means into code-learning mode)
d. Press any button on transmitter once in 10 seconds, when siren wails once means the 1st code
learning is done. After that, press another transmitter any button once in 10 seconds, when siren wails
twice means the 2nd code learning is done. Following the same procedure, it can learn 6 different
transmitter’s code.
REMARK: If the transmitter doesn‘t receive any input in 10 seconds, LED light will distinguish. System
will leave the code-learning mode and enter to user mode automatically.
3. System will Memorize Status Records Prior to Electricity Cut-Off:
Prior to system’s electricity cut-off, system will memorize the status prior to cut-off. At any time, when the
electricity is resumed, system will immediately enter into the status prior to cut-off. If system’s electricity
is cut-off during override status, then system will immediately enter into “override mode” upon the
electricity is resumed. If system’s electricity is cut-off during arming status, then system will immediately
enter into “alarm triggering mode” upon the electricity is resumed.