Datasheet

01-2016, Rev. 0116
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
1
AXICOM
Signal Relays
IM - E Relay
n
Minimum board-space 60mm
2
n
Slim line 10x6mm (0.39x0.24”) and
n
Low profile 5.65mm (0.222”)
n
Switching power 60W/62.5VA
n
Switching voltage 220VDC/250VAC
n
Switching current 2A
n
Bifurcated contacts
n
High mechanical shock resistance
Typical applications
Telecommunication, access and transmission equipment, optical network
terminals, modems, office and business equipment, consumer electronics,
measurement and test equipment, industrial control, medical equipment
Approvals
UL 508 File No. E 111441
Technical data of approved types on request
Contact Data
Contact arrangement 2 Form A, 2 NO
Max. switching voltage 220VDC, 250VAC
Rated current 2A
Limiting continuous current 2A
Switching power 60W, 62.5VA
Contact material PdRu
Au covered
Contact style twin contacts
Minimum switching voltage 100µV
Initial contact resistance <50mΩ at 10mA/30mV
Thermoelectric potential <10µV
Operate time typ. 1ms, max. 3ms
Release time
without diode in parallel typ. 1ms, max. 3ms
with diode in parallel typ. 3ms, max. 5ms
Set/reset time max. typ. 1ms, max. 3ms
Bounce time max. typ. 1ms, max. 5ms
Electrical endurance
at contact application 0
(≤30mV/≤10mA) min. 2.5x10
6
operations
cable load open end min. 2.0x10
6
operations
resistive, 125VDC / 0.24A - 30W min. 5x10
5
operations
resistive, 220 VDC / 0.27A - 60W min. 1x10
5
operations
resistive, 250VAC / 0.25A - 62.5VA min. 1x10
5
operations
resistive, 30VDC / 1A - 30W min. 5x10
5
operations
resistive, 30VDC / 2A - 60W min. 1x10
5
operations
Contact Data (continued)
UL contact rating 30VDC, 2A, 60W, NO only
110VDC, 0.3A, 33W
220VDC, 0.27A, 60W
125VAC, 0.5A, 62.5W
250VAC, 0.25A, 62.5W
Mechanical endurance 10
8
operations
Coil Data
Coil voltage range 1.5 to 24VDC
Max. coil temperature 125°C
Thermal resistance <150K/W
Coil versions, standard version, monostable, 1 coil
Coil Rated Operate Release Coil Rated coil
code voltage voltage voltage resistance power
VDC VDC VDC Ω±10% mW
01 3.0 2.25 0.30 64 140
02 4.5 3.38 0.45 145 140
03 5.0 3.75 0.50 178 140
06 12.0 9.00 1.20 1029 140
All figures are given for coil without pre-energization, at ambient temperature +23°C
108-98001 Rev. M
All specifications subject to change. Consult Tyco Electronics for latest specifications. 21 of 28
AXICOMÊSignalÊRelays
IM Relay
Contact Data
IM-A IM-B IM-C IM-D IM-E
Number of contacts and type
1ÊPoleÊbreak 1ÊPoleÊmake 1ÊPoleÊÊ
changeover
2ÊPoleÊbreak 2ÊPoleÊmake
Contact assembly
BifurcatedÊcontacts
Contact material
Palladium-ruthenium,Êgold-covered
Limiting continuous current
at max. ambient temperature
A2ÊA A2ÊA A
Maximum switching current
2ÊA 2ÊA 3ÊA 2ÊA A
Maximum swichting voltage
220ÊVdc
250ÊVac
Maximum switching capacity
60ÊW,Ê62.5ÊVA
Thermoelectric potential
<Ê10ʵV
Minimum switching voltage
100ʵV
Initial contact resistance /
measuring condition: 10 mA / 20 mV
< 100 < 100 NO < 100 < 50 < 50
Electrical CC0 Contact category 0
endurance (≤ 30 mV / ≥ 10 mA)
cable load open end
Resistive load at 125 Vdc / 0.24 A - 30 W
at 220 Vdc / 0.27 A - 60 W
at 250 Vac / 0.25 A - 62.5
VA
at 30 Vdc / 1 A - 30 W
at 30 Vdc / 2 A - 60 W
min.Ê2.5ÊxÊ10
6
Êoperations
min.Ê2.0ÊxÊ10
6
Êoperations
min.Ê5ÊxÊ10
5
Êoperations
min.Ê1ÊxÊ10
5
Êoperations
min.Ê1ÊxÊ10
5
Êoperations
min.Ê5ÊxÊ10
5
Êoperations
min.Ê1ÊxÊ10
5
Êoperations
Mechanical endurance
typ.Ê10
8
Êoperations
UL contact ratings 220 Vdc / 0.24 A - 60 W
125 Vdc / 0.24 A - 30 W
250 Vac / 0.25 A - 62.5 VA
125 Vac / 0.5 A - 62.5 VA
30 Vdc / 2 A - 60 W
Max. DC Load Breaking Capacity
DC Voltage [Vdc]
DC current [A]
resistive load
Max. DC load breaking capacity
Coil operating range, standard version