1
n
Small power relay
n
Limiting continuous current 30A
n
Low weight
n
Low noise operation
n
Wave (THT) and reflow (THR/pin-in-paste) solderable versions
Typical applications
Car alarm, door control, door lock, heated front/rear screen, immobilizer,
lamps front/rear/fog light, interior lights, seat control, sun roof, window
lifter, wiper control.
Micro Relay K (THT – THR)
Automotive Relays
PCB Single Relays
Contact Data
Typical applications Inductive load Wiper load Resistive/inductive load Lamp load
5)
V23086-*1*01-A403 V23086-*1*02-A803 V23086-*1*01-A402 V23086-*1*51-A502
Contact arrangement 1 form C, 1 CO 1 form C, 1 CO 1 form A, 1 NO 1 form A, 1 NO
Rated voltage 12VDC 10VDC 12VDC 12VDC
NO/NC NO/NC
Rated current 30/25A 30/25A 30A 30A
Limiting continuous current
23°C 30/25A 30/25A 30A 30A
85°C 20/15A 20/15A 20A 20A
Limiting making current 40A
1)
40A
1)
40A
1)
100A
2)
Limiting breaking current 30A 30A 30A 30A
Contact material AgSnO
2
Min. recommended contact load 1A at 5VDC
3)
Initial voltage drop at 10A, typ./max. 30/300mV
Operate/release time typ. 3/1.5ms
4)
Electrical enduranc
cyclic temperature -40°C, +25°C, +85°C
form C contact (CO) at 14VDC motor reverse blocked, wiper,
25A, 0.77mH 25A make/5A break,
>1x10
5
ops. generator peak,
20A on NC,1mH
>1x10
6
ops.
form A contact (NO) at 14VDC resistive 20A lamp 100A inrush,
>3x10
5
ops. 10A steady state
>1x10
5
ops.
5)
Mechanical endurance >5x10
6
ops.
Max. DC load breaking capacity
Load limit curve 1: arc extinguishes, during transit time (changeover contact).
Load limit curve 2: safe shutdown, no stationary arc (make contact).
Load limit curves measured with low inductive resistors verified for 1000 switching events.
1) The values apply to a resistive or inductive load with suitable spark suppression and at
maximum 13.5VDC for 12VDC load voltages. For a load current duration of maximum
3s for a make/break ratio of 1:10.
2) Corresponds to the peak inrush current on initial actuation (cold filament).
3) See chapter Diagnostics of Relays in our Application Notes or consult the internet at
http://relays.te.com/appnotes/
4) Measured at nominal voltage without coil suppression unit. A low resistive suppression
device in parallel to the relay coil increases the release time and reducesthe lifetime
caused by increased erosion and/or higher risk of contact tack welding.
5) Be aware of using right polarity, see Terminal Assignment. Wrong polarity will reduce
endurance.
086C/R1_fcw1b