User's Manual

T&D Corporation
Shimadachi 817-1, Matsumoto, Nagano 390-0852 JAPAN
Fax: +81-263-40-3152 E-mail: support@tandd.com
Website: http://www.tandd.com/
Wireless Core Temperature Data Logger
User's Manual
© Copyright T&D Corporation All rights reserved.
2010.03 16504390003 (3rd Edition)
This is printed on recycled paper.
RTR-601
If the unit gets dirty, wipe it with a
clean cloth dipped in alcohol; DO
NOT WASH with WATER.
NEVER use an acid, alkaline, or
chlorine based detergent. This will
cause harm to the electric
components in the unit.
Before and after using, please
clean to remove any substances
attached to the surface and
sterilize the units in order to
prevent the growth of bacteria.
Explanation of Symbols
DANGER
These entries are actions that absolutely under no
circumstance should be taken. The taking of such an action
may cause serious personal physical damage or death.
CAUTION
These entries are actions that if taken may lead to physical
injury or damage to persons or things.
Explanation of Picture Symbols
Denotes an important warning or caution. Inside or near the symbol
will appear another symbol giving details.
Denotes a forbidden action. Inside or near the symbol will appear
another symbol giving details.
Denotes an action that you must take. Inside or near the symbol will
appear another symbol giving details.
Safety Precautions and Requests
*Please carefully observe the following safety measures when using our product.
To prevent any loss or damage to our customers, other people and / or property, and to ensure the proper use of our products we ask that before using our
product you carefully read, understand and follow the safety rules and precautions for our products as outlined below.
DANGER
Do not take apart, repair or modify the Unit.
Doing so may cause fire or electrocution.
If any smoke or strange smells are emitted from the Unit,
immediately remove batteries and stop using.
Continued use may cause fire or electrocution.
Do not use any other batteries than those that are specified in
this Manual.
It may cause a fire or other trouble including malfunction.
If water or a foreign body enters the Unit, immediately remove
batteries and stop using.
Continued use may cause fire or electrocution.
The Unit is a device to measure temperature.
Do not use the Unit for any purpose other than temperature measurement.
Store the Unit and batteries out of the reach of children.
It is dangerous to touch or swallow them.
Wireless Regulations
Radio, EMC and Safety Regulations
This device complies with Part 15 of the Federal Communications Commission
(FCC) rules. Operation is subject to the following two conditions: (1) This device
may not cause harmful interference, and (2) This device must accept any
interference received, including interference that may cause undesired
operation.
Caution:
Changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
Note about Antenna Usage:
This device has been designed to operate with the supplied antenna only. Use of any
other antenna is strictly prohibited.
IC Statement
This device complies with RSS-210 of the Industry Canada (IC). Operation is subject to
the following two conditions: (1) This device may not cause harmful interference; and (2)
This device must accept any interference received, including interference that may cause
undesired operation.
Ce dispositif est conforme à la norme RSS 210 d’Industrie Canada.
L’utilisation de ce dispositif est autorisée seulement aux conditions suivantes : (1) il ne
doit pas produire de brouillage et (2) l’utilisateur du dispositif doit être prêt à accepter
tout brouillage radioélectrique reçu, même si ce brouillage est susceptible de
compromettre le fonctionnement du dispositif.
Important Notice
Wireless products cannot be used in countries other than where those products
have been approved for use, according to that country's wireless regulations.
T&D Corporation shall in no manner whatsoever take responsibility for the usage
of these products, nor be liable in any manner for legal consequences stemming
from the usage of these wireless products in unapproved areas.
CAUTION
We are not responsible for any damage, malfunction or trouble,
whether direct or indirect, caused by the use of our product.
Please be fully aware of this before using our product.
This Unit has been designed for private or industrial use only. It is
not for use in situations where strict safety precautions are
necessary such as in connection with medical equipment,
whether directly or indirectly.
To prevent damage to the Unit from static electricity, remove static
electricity from your body by touchinxe Unit.
Static electricity may cause not only damage to the Unit, but may cause breaks
in or a loss of data.
Use the Unit under conditions with an ambient temperature of -10
to 60
o
C.
The Unit only becomes water resistant (IP64 splash resistant) if
the temperature sensor has been connected.
Without the sensor connected, the connector part of neither the main unit nor the
temperature sensor is water resistant; make sure not to get wet.
Do not expose the unit to harmful gases or chemicals.
It may cause corrosion and/or other danger to the unit and to people handling
the unit.
Do not drop the Unit, or expose it to a strong impact. If that
happens, immediately disconnect the cables, remove batteries,
and stop using.
Continued use may cause fire or electrocution.
Battery terminals may provide insufficient contact due to age or
vibration.
This may lead to data loss.
Battery life depends on the measurement environment,
communication frequency, recording interval and battery quality.
Remove batteries from any Unit that is not to be used for a long
period of time.
Batteries left in a Unit not being used for a long time may leak and cause a
malfunction.
Do not use or store the unit in places such as listed below:
-Areas exposed to direct sunlight
-Areas exposed to water or high-pressure water flow.
-Areas exposed to organic solvents and corrosive gas.
-Areas exposed to strong magnetic fields
-Areas exposed to static electricity.
-Areas exposed to fire or overheating.
-Areas exposed to excessive dust or smoke.
Important Notices and Disclaimers
In order to properly use this product, please carefully read this manual
before using.
- T&D Corporation accepts no responsibility for any malfunction of and/or
trouble with this product or with your computer that is caused by the
improper handling of this product and will deem such trouble or malfunction
as falling outside the conditions for free repair outlined in the attached
warranty.
- All rights of this User's Manual belong to T&D Corporation. It is prohibited to
use, duplicate and/or arrange a part or whole of this User’s Manual without
the permission of T&D Corporation.
- All registered trademarks, company names, product names and logos
mentioned herein are the property of T&D Corporation or of their respective
owners.
- Specifications, design and other contents outlined in this manual are subject
to change without notice.
- Please follow the safety precautions outlined in this manual carefully.
- We cannot guarantee nor are we responsible for safety if this product is
used in any manner other than was intended.
- On screen messages in this manual may vary slightly from the actual
messages.
- Please notify the shop where you purchased this product or T&D
Corporation of any mistakes, errors or unclear explanations in this manual.
- T&D Corporation accepts no responsibility for any damage or loss of
income caused by the use of our product.
- This product has been designed for private or industrial use only.It is not for
use in situations where strict safety precautions are necessary such as in
connection with medical equipment, whether directly or indirectly.
- We are not responsible for any malfunction or trouble caused by the use of
our product or by any problem caused by the use of measurement results of
our unit. Please be fully aware of this before using our product.
- This User’s Manual cannot be reissued, so please keep it in a safe place.
- Please read the warranty and provisions for free repair carefully.
Because the sensor has a sharp tip,
there is a risk of accidentally stabbing
people and/or objects. Do not use the
sensor for any purpose other than
measuring the temperature of objects
for which it was designed and store in
a safe place when not in use.
Please be careful when using in
extreme hot or cold environments;
touching the unit may cause burns
or frostbite.
DO NOT TOUCH SENSOR IMMEDIATELY AFTER
MEASUREMENT
DAILY MAINTENANCE
DO NOT POINT THE SENSOR TOWARD HUMANS OR
USE IN WAYS OTHER THAN THOSE FOR WHICH THIS
PRODUCT WAS DESIGNED
CLEAN AND STERILIZE UNITS BEFORE AND AFTER
USE
CAUTION:
EXTREME HOT
& COLD!
DO NOT
TOUCH!
DANGER!
Use Safety
Cover
What is RTR-601?
Thermo Recorder Push Wireless RTR-601 is a handy-type device which acts both as a thermometer
and a temperature recorder, which has been designed to easily measure and record the internal
temperature of food items and liquid temperature using a needle-type sensor.
This product has been designed to meet IP64 standards (splash resistant; rated for use in daily
life). RTR-601 measures and records core temperature, which makes it suitable for use in the food
production industry especially temperature management for HACCP.
The unit incorporates a battery life warning function, which informs the user when it is time to
replace the battery. When the battery power becomes low, all normal operations will stop in order to
protect the data.
The LCD Backlight allows the display to be easily read even in low light. The LCD contrast can also
be easily adjusted for better viewing.
These units are also designed with short range wireless functions that when coupled with our
exclusive software set "Push Wireless Communication Set (RTR-601SK)", makes it possible to carry
out wireless communication, allowing for easy and effective management of multiple RTR-601 units.
Package of Contents
Part Names and Functions
Judgment LED (Red / Green)
The Judgment result of temperature
measurement will be shown. Out of Range:
Red LED will blink. Within Range: Green LED
will blink.
*Judgment LED Settings
By changing settings, it is possible to turn ON
or OFF the Judgment LED function.
RTR-601 Main Unit
(Sensor attached)
User's Manual
Warranty
(this document)
LCD Display
The RTR-601 is designed with a graphic LCD
display with a resolution of 132 x 64 pixels.
* Backlight Function
The LCD Backlight makes the display easier to
read in low light conditions.
* Contrast Adjustment Function
The display contrast can be adjusted here.
By pressing this button, the Menu will be
displayed. Also, press to return to the previous
window.
Press to enter the settings menu or determine
the settings.
Temperature Sensor
As for details about how to remove or change
the sensor, please see the User's Manual that
comes with the sensor you will be using.
Please be careful when handling the
temperature sensor.
PUSH Record LED (Orange)
By pressing the <REC> button, the lamp will
turn on when a temperature measurement is
recorded.
* The recorded object is the temperature at the
instant when the <REC> button is pressed.
<REC> Button (Record)
When this button is pressed, the Temperature,
Date / Time, User Name, Item, and Judgment
Result at the time of pressing are recorded into
the RTR-601.
Cursor Buttons
(Moving Up and Down)
Press to move the Cursors up and down on the
display.
Power Button
Press to turn on / off the power.
*Automatic Power-OFF Function
If the unit is not used for about five minutes, it will
automatically turn off.
*Automatic Power-ON Function
If a unit is OFF, when wireless or optical
communication is carried out by a Management
Operator, that unit will be automatically turned
ON.
<MENU> Button
<ENT> Button
RTR-601 Series
RTR-601-110: All-in-One Short Type Set
Main Unit (RTR-601)+All-in-One Short Type Sensor
RTR-601-130: All-in-One Long Type Set
Main Unit (RTR-601)+All-in-One Long Type Sensor
RTR-601-E10: Separate Short Type Set
Main Unit (RTR-601)+Separate Short Type Sensor
RTR-601-E30: Separate Long Type Set
Main Unit (RTR-601)+Separate Long Type Sensor
*Common Items Included:
User's Manual (this document)
Temperature Sensor (Optional)
All-in-one Type Temperature Sensor
(Sensor directly attached to the RTR-601 Main Unit)
[Unit:mm]
RTR-60110: Short Temperature Sensor
Sensor Length: 125mm
RTR-60130: Long Temperature Sensor
Sensor Length: 300mm
Separate Type Temperature Sensor
(Sensor with Handgrip and Cord. Easy to measure temperature, even in steam.)
[Unit:mm]
126
RTR-60E10: Short Temperature Sensor
Sensor Length: 125mm
Cord Length: 900mm
RTR-60E30: Long Temperature Sensor
Sensor Length: 300mm
Cord Length: 900mm
Sensor Materials: Stainless pipe(SUS316).
Handgrip Materials: Flame Resistant PPE / PA6 (Temperature Durability: About 170
o
C)
Cord Materials: Fluoropolymer-Coated Electrical Wire
Common Items Included:
Sensor Spacer 1 / Rubber Packing 1 / Sensor Replacement Tool 1 / Sensor User's Manual 1