User’s Manual TR3-C202-A0-8 Manual No.
Introduction Thank you for purchasing a TR3-C202-A0-8 RFID READER/WRITER. Be sure to read this manual before using the product. After reading it, store the manual in a convenient place for future reference. Manual No.
Regulations and Standards FCC This product is conform to the FCC standards. FCC Rules (Federal Communications Commission) This product complies with Part 15 Subpart C of the FCC Rules. FCC ID : MK4TR3-C202-A0-8 This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Safety Precautions The following symbols are used in this manual to indicate precautions that must be observed to ensure safe use of this product. The precautions provided here contain important safety information. Be sure to observe these precautions. The following signal words are used in this manual. Failure to comply with a WARNING may result in serious injury or death. Failure to comply with a CAUTION may result in injury to the operator, or damage to the items involved.
Contents 1 Product Overview ................................................................ ................................................................................................ ...................................................................... ...................................... 1 1.1 2 Features .............................................................................................................................................. 1 Names of Parts and Functions .................
1 Product Overview 1.1 Features 1 Product Overview 1.1 Features This product uses the 13.56MHz frequency. This product is the electromagnetic induction type non-contact IC can read and write RFID tag data. This Product is designed to be embedded and integrated within OEM devices and finished products such as label printers, cashless payment terminals or any other device that can benefit from integrated RFID capabilities.
2 Names of Parts and Functions 2.1 TR3-C202-A0-8 2 Names of Parts and Functions 2.1 TR3-C202-A0-8 ③ ① ④ ② ⑤ ⑥ ⑦ No ① ② Name Screw holes STUD NUTS ③ ④ ⑤ LED1 CN1 Nameplate Description M3 holes Internally, substrate is fixed at stud nats. M3 Screw hole depth : 3mm Displays the status of this product. This connector is for connection to the host. Production numbers, will be 8-digit serial number. Model Name Serial number:********(F) ⑥ ⑦ FCC ID stickers CH1 to CH8 Connect the antenna cable.
2 Names of Parts and Functions 2.2 Antenna 2.2 Antenna 2.2.1 TR3-A202 ① ② ③ ④ No ① ② Name CN1 Nameplate Description Connect the antenna cable. Production numbers, will be 8-digit serial number. Model Name Serial number:********(F) ③ ④ Inspection mark Screw holes M3 holes Manual No.
2 Names of Parts and Functions 2.2 Antenna 2.2.2 TR3-A302 ① ② ④ ③ No ① ② ③ Name Inspection mark Screw holes Nameplate Description M3 holes Production numbers, will be 8-digit serial number. Model Name Serial number:********(F) ④ 2.2.3 CN1 TR3-A401 ① No ① ② Connect the antenna cable. Name CN1 Nameplate ② ③ Description Connect the antenna cable. Production numbers, will be 8-digit serial number. Model Name Serial number:********(F) ③ Inspection mark Manual No.
3 Installation and connection 3.1 Installation into a host device 3 Installation and connection 3.1 Installation into a host device 3.1.1 Installation from the Front Four, M3 holes M3 Screw Host Device Manual No.
3 Installation and connection 3.2 Antenna installation into a host device 3.2 Antenna installation into a host device 3.2.1 Screw holes M3 Screw 3.2.2 Guide TR3-A401 is recommended that you set up a guide on fixed-like the figure below. Host Device TR3-A401 Manual No.
3 Installation and connection 3.3 Connection 3.3 Connection This product will connect with the antenna and antenna cables. This product connects with Host Device that direct connection or connect using our interface. 3.3.1 Attaching the Cable and Antenna Host Device TR3-C202-A0-8 Antenna Antenna Cable 3.3.2 Direct connection to the Host Device Interface Please prepare to the interface harness. Host Device TR3-C202-A0-8 Host Device Interface Manual No.
3 Installation and connection 3.3 Connection 3.3.3 Using the interface board to connect to the Host Device Interface Interface board, please contact us. Host Device TR3-C202-A0-8 Interface harness Interface Cable Host Device Interface Interface board Manual No.
4 Specifications 4.1 TR3-C202-A0-8 4 Specifications 4.1 TR3-C202-A0-8 ■ Specifications Specifications Item Applicable Japan Radio Law Standards FCC Radio Frequency Parameter ARIB STD-T82 FCC Part 15 Subpart C FCC ID : MK4TR3-C202-A0-8 RoHS EU RoHS(2002/95/EC) Supports Carrier frequency 13.56MHz ±50ppm(Ta=25℃) or less Transmit power or 10 to 100mW ± 20% power range (Transmit power range varies with input voltage.
4 Specifications 4.1 TR3-C202-A0-8 Specifications Item Controll Command Host Interface Connector LED1 CN1 Parameter Please refer to the TR3-C202 Protocol-Manual. UART(CMOS) Item Parameter Speed 9600bps 19200bps(※2) 38400bps Data bits 8 Parity None Stop bit 1 Flow control None 1pc (3 colors, red/green/orange) Connector : JST S10B-PH-SM4-TB(LF)(SN) Housing : JST PHR-10 Contact : JST SPH-002T-P0.5S Pin assignment Pin No.
4 Specifications 4.1 TR3-C202-A0-8 Specifications Item Mechanical Dimensions data (W x D x H) Wight Installation Electrical data Power Ambient Conditions Temperature Operating range Humidity Operating range Temperature Storage range Humidity Storage range Accessories Other Manual No.TDR-MNL-C202-A0-8-EN-101 Parameter 103.6 x 103 x 23.3mm approx. 240g M3 Screw Screw is not included. Supply Voltage Current consumption Carrier off Power down mode Consumption 0 to 55 degree :+3.3± 10%, +5V ± 10% :approx.
4 Specifications 4.1 TR3-C202-A0-8 ■ Dimensions Unit:mm Tolerance:±1mm ( )is Recommended Dimension Manual No.
4 Specifications 4.1 TR3-C202-A0-8 ■ Connections Names Antenna Cable Interface board Model Notes TR3-A202 TR3-A302 TR3-A401 TR3-AC-2A-*** *** puts the cable length. 0.5m ~ 3m cable are available. RS232C interface TCP/IP interface USB interface TR3-IF-1C TR3-IF-N1 TR3-IF-U1 ■ Electrical Characteristics(CN1、CN3) VDD=5.0V Item Condition H input voltage L input voltage H output voltage IOH=-5mA,-20mA L output voltage IOL=5mA,20mA Pull-up resistor MIN 2.5 0 3.0 25.0 TYP 50.0 MAX 5.0 1.0 2.0 100.
4 Specifications 4.2 Antenna 4.2 Antenna 4.2.1 TR3-A202 ■ Specifications Specifications Item Applicable RoHS Standards Antenna Resonant frequency Communication distance Connector CN1 Parameter EU RoHS(2002/95/EC) Support 13.56MHz ±40kHz(Ta=25℃) Max 10cm (Communication distance depends on the environment.) Connector : JST S2B-PH-SM4-TB(LF)(SN) Housing : JST PHR-2 Contact : JST SPH-002T-P0.5S Pin assignment Pin No.
4 Specifications 4.2 Antenna 4.2.2 TR3-A302 ■ Specifications Specifications Item Applicable RoHS Standards Antenna Resonant frequency Communication distance Connector CN1 Parameter EU RoHS(2002/95/EC) Support 13.56MHz ±40kHz(Ta=25℃) Max 7cm (Communication distance depends on the environment.) Connector : JST S2B-PH-SM4-TB(LF)(SN) Housing : JST PHR-2 Contact : JST SPH-002T-P0.5S Pin assignment Pin No.
4 Specifications 4.2 Antenna 4.2.3 TR3-A401 ■ Specifications Specifications Item Applicable RoHS Standards Antenna Resonant frequency Communication distance Connector CN1 Parameter EU RoHS(2002/95/EC) Support 13.56MHz ±40kHz(Ta=25℃) Max 5cm (Communication distance depends on the environment.) Connector : JST S2B-PH-K-S(LF)(SN) Housing : JST PHR-2 Contact : JST SPH-002T-P0.5S Pin assignment Pin No.
4 Specifications 4.3 Cable 4.3 Cable ■ Model Name TR3-AC-2A-*** Enter the cable length(Unit:m) 0.5M~3M ■ Specifications Item RoHS Linetype Connector Cable loss Parameter EU RoHS(2002/95/EC) Support Coaxial cable 1.5D-2V PH-PH 0.5M : approx. 0.043dB 3M : approx. 0.255dB ■ Dimensions (Cable length) ( )is Recommended Dimension Manual No.
5 Maintenance This product is mainly used in electronic components and semiconductors. Therefore, the long-term stable operation, the environment and conditions are expected to defect, as shown below. • Device degradation due to overvoltage and overcurrent. • Device degradation due to high temperature and long-term stress. • Poor contact of the connector and cause deterioration of insulation by moisture or dust. • Connector corrosion by corrosive gases.
Revision History Revision code 1.00 1.01 Date 2010/4/16 2011/03/03 Revised contents Original production 3.1.2 Installation from the Front deleted. 4.1 TR3-C202-A0-8 Add to 3.3V input voltage. Manual No.
[URL] [Mail] http://www.takaya.co.jp/ rfid@takaya.co.