User's Manual

TB8100 Installation and Operation Manual Installation 69
© Tait Electronics Limited March 2005
5 Installation
This chapter describes how to install the TB8100 BSS in a standard 19 inch
rack or cabinet. It also provides some general information on safety
precautions and site requirements. We recommend that you read the entire
chapter before beginning the installation.
5.1 Personal Safety
5.1.1 Lethal Voltages
Warning!! The PMU contains voltages that may be lethal.
Refer to the ratings label on the rear of the
module.
The TB8100 BSS must be installed so that the rear of the PMU is located
in a service access area. The PMU must be connected to the mains supply
source by trained personnel in accordance with local and national
regulations.
Disconnect the mains IEC connector and wait for five minutes for
the internal voltages to self-discharge before dismantling. The AC
power on/off switch does not isolate the PMU from the mains. It
breaks only the phase circuit, not the neutral.
The PMU should be serviced only by qualified technicians. There are no
user-replaceable parts inside. If the PMU is damaged and does not function
properly, stop the module safely and contact your nearest Tait Dealer or
Customer Service Organisation immediately.
All servicing should be carried out only when the PMU is powered through
a mains isolating transformer of sufficient rating. We strongly
recommend that the mains power to the whole of the repair and test area
is supplied via an earth leakage circuit breaker.
5.1.2 Explosive Environments
Warning!! Do not operate TB8100 BSS equipment near
electrical blasting caps or in an explosive atmos-
phere. Operating the equipment in these envi-
ronments is a definite safety hazard.