TR-PS1 Textile Rental Programming Station User's Guide Revision 1.
TR-PS1 Textile Rental Programming Station User's Guide Publishing Information Disclaimer and Limitation of Liability All information herein is either public information or is the property of and owned solely by TAGSYS who shall have and keep the sole right to file patent applications or any other kind of intellectual property protection in connection with such information.
Read This First Read This First Welcome to the TAGSYS Textile Rental (TR) Programming Station system. This user's guide is designed to help you get up and running quickly using this high-quality Radio Frequency Identification (RFID) system. It describes all you need to know about how to install and use the TAGSYS system and its associated applications.
TR-PS1 Textile Rental Programming Station User's Guide EAS Electronic Article Surveillance ETX End of Text HPI Host Port Interface I/O Input/Output IFD Interface Device LED Light Emitting Diode LSb Least Significant Bit LSB Least Significant Byte MSb Most Significant Bit MSB Most Significant Byte OS Operating System PC Personal Computer PCB Printed Circuit Board RAM Random Access Memory RF Radio Frequency RFID Radio Frequency IDentification RFU Reserved for Future Use RPU
Read This First Dynamic-Link Library Executable routines that are stored as separate files with DLL extensions and executed only when needed by the program. Host Port Interface Interface used to access the DSP memory. IEC Connector Three-pin connector used on sockets that carry mains electricity to the computer. All PCs use a male IEC connector and mains lead with a female IEC connector. Interrogation Pulse A signal transmitted by the coupler to activate the smart label’s transponder.
TR-PS1 Textile Rental Programming Station User's Guide If you need assistance Please contact your nearest TAGSYS sales representative or the TAGSYS welcome desk at: Telephone: Fax: E-Mail: +33 (0) 4 91 27 57 00 +33 (0) 4 91 27 57 01 info@tagsys.net Contact for Comments We welcome your feedback to help us provide high quality documentation. For technical comments, please contact our welcome desk: Telephone: Fax: E-Mail: +33 (0) 4 91 27 57 00 +33 (0) 4 91 27 57 01 info@tagsys.
Read This First Table of Contents Publishing Information 2 Disclaimer and Limitation of Liability 2 Read This First 1 Conventions Abbreviations and Acronyms Glossary If you need assistance Contact for Comments Quality Issues 3 3 4 6 6 6 For Your Safety 9 1.1 1.2 1.3 9 9 9 General Use Care and Maintenance Important Safety Information 1.3.1 1.3.2 2 3 4 5 8 9 10 11 2.1 2.2 Occupational Health and Safety Notices Regulatory Notices 11 11 2.2.1 2.2.2 2.2.
TR-PS1 Textile Rental Programming Station User's Guide 9 Warranty Conditions 28 9.1 9.2 Warranty Warranty Exclusions 28 28 9.2.1 9.2.2 29 29 8/30 General Provisions How to Return Defective Products Revision 1.
For Your Safety 1 For Your Safety 1.1 General Use The TR-PS1 Textile Rental Programming Station system is designed to be rugged and reliable and to provide years of trouble-free service. Please observe the following general tips: Take care not to scratch the device. Keep the device clean. When working with the device, use only TAGSYS-approved accessories. This device is not waterproof and should not be exposed to rain or moisture. Under extreme conditions, water may enter the circuitry.
TR-PS1 Textile Rental Programming Station User's Guide When connecting the device or any accessory to another device, read its user’s guide for detailed safety instructions. Do not connect incompatible products. As with all RF equipment, users are advised that the equipment should only be used in its normal operating position. 1.3.2 Electronic Devices Most modern electronic equipment is shielded from radio-frequency (RF) signals.
Certification 2 Certification 2.1 Occupational Health and Safety Notices TAGSYS Products have been designed not to exceed the limits given in the European Standard EN 50364 “Limitation of human exposure to electromagnetic fields from devices used in Electronic Article Surveillance (EAS), Radio Frequency Identification (RFID) and similar applications” in conjunction with the European Standard EN 50357 describing how to evaluate the exposure level.
TR-PS1 Textile Rental Programming Station User's Guide 2.2.2 In USA (FCC Directive) The TR-PS1 Textile Rental Programming Station has been designed to comply with Part 15 of the FCC Rules. Furthermore typical configurations based on a Medio S002 have been successfully tested with Part 15 of the FCC rules (FCC ID Number Pending). TR-PS1 Textile Rental Programming Station WARNING TO USERS IN THE UNITED STATES FEDERAL COMMUNCIATIONS COMMISSION (FCC) RADIO INTERFERENCE STATEMENT 47 CFR Section 15.
Overview 3 Overview 3.1 TR-PS1 Programming Station The Textile Rental Programming Station (TR-PS1) is a low-profile smart tags reader unit that includes the electronics required to read smart tags through its built-in antenna (Figure 1). Specifically designed for use in Textile Rental applications the TR-PS1 can work with most smart tags and will be compliant with the future ISO18000 standard.
TR-PS1 Textile Rental Programming Station User's Guide 3.
Installation 4 Installation 4.1 Standard Installation The Textile Rental Programming Station (TR-PS1) has been designed for indoor use: On wooden or composite desks (not too close to metallic parts) In proximity with other TR-PS1 Programming Stations Note that the sides of the TR-PS1 are slanted. This ergonomic feature was designed in order to be able to slide items on/off the active face; saving time and effort. 1.
TR-PS1 Textile Rental Programming Station User's Guide 3. Connect the male jack of the jumper cable to the female jack of the TR-PS1 Programming Station serial connector as shown in Figure 3. This PS/2 jumper connection is used to supply power to the TR-PS1 Programming Station. 4. Connect the jumper cable to the PS/2 port of the host PC and connect the peripheral connector (mouse or keyboard) to the other end.
Operation 5 Operation 5.1 Smart Labels The TR-PS1 Programming Station is capable of reading most types of smart labels. Smart labels must be encapsulated in a highly resistant plastic casing when used in Textile Rental applications. 5.1.1 Chip Types There are three major types of smart labels used in Textile Rental applications. Each type of label has its own special features as described in Table 2. Table 2: Smart Label Types Features Ario™ 10SL Ario™ 20SL Ario™ 70TL Read Distance 45 mm. (1¾ in.
TR-PS1 Textile Rental Programming Station User's Guide 5.3 Firmware The firmware stored inside the TR-PS1 Programming Station is designed for use as a Standalone system. When the smart label enters the 13.56-RF field, the TR-PS1 reads its serial number and sends it to the host PC via the RS communication link in ASCII format. When set in Continuous mode, the TR-PS1 sends the smart label data each time the smart label is read.
How to Improve Performance 6 How to Improve Performance In certain cases when the Textile Rental Programming Station (TR-PS1) is installed in a highly metallic environment, its reading performance can be significantly reduced. In this event, it is strongly recommended changing the location of the TR-PS1 Textile Rental Programming Station. 6.1 Verification of L-PS1 Performance The S002 Explorer software tool is used to verify the reading performance of the TR-PS1 Programming Station. Procedure: 1.
TR-PS1 Textile Rental Programming Station User's Guide Figure 6: General Reader Settings 6. In the Commands menu, click C220 and select Default Read. 7. In the Default Read dialog box, click Read. Figure 7: Default Read Window 8. Using a ruler, measure the distance in which the antenna is able to read a Folio 20 smart label. If this distance is less than 100 mm., you should verify the tuning of the antenna. 20/30 Revision 1.
How to Improve Performance 6.2 Tuning Procedure The TR-PS1 Programming Station antenna must be re-tuned only by an approved TAGSYS integrator or by a TAGSYS technical consultant. Any attempt by a non-qualified third-party to retune the antenna will void the product’s warranty. 1. Unscrew the four screws on the sides of the TR-PS1 Programming Station and remove the antenna cover. 2. Remove the jumper on Test Points 1 and 2. 3. Connect the 2-pin connector of the TAGSYS Tuning Kit to Test Points 3 and 2.
TR-PS1 Textile Rental Programming Station User's Guide 6.3 Upgrading the Firmware The TR-PS1 Textile Rental Programming Station has the capability to have firmware upgrades. This feature allows you to protect your investment by upgrading your TR-PS1 Programming Station when an enhanced chip-decoding algorithm or new chip drivers become available. Upgrading the Firmware of the TR-PS1 Programming Station is a straightforward operation. 1. Install the S002 Explorer software tool on your PC.
How to Improve Performance Figure 12: Upgrade Firmware Window 7. The Download procedure may take several minutes. A progress bar is displayed. Figure 13: Entering Firmware Key 8. If the new firmware has been successfully downloaded, a message is displayed. If the final dialog box at the end of the procedure contains an error message, reload the original firmware supplied with the TR-PS1 Programming Station and contact your approved TAGSYS representative. May 2003 Revision 1.
TR-PS1 Textile Rental Programming Station User's Guide 9. Click OK to reset the TR-PS1 Programming Station. Always use Firmware upgrades supplied by TAGSYS. If you have any doubt on the origin of the firmware you intend to download; contact your TAGSYS approved reseller. Any attempt to download a Firmware supplied by a third party may lead to permanent damages to the TR-PS1 Programming Station. Never interrupt the Firmware upgrade procedure while the firmware is being downloaded.
T h T -iP S P ro a n g S tfe a n co n tca in o p rn s.te rvivice e a b p a n d m sS t1 o n lyb e srn va in ciR e b u a ig fre d p e se o lS .a N rg e la rm e ve irtce g sa e q u d ,m xicrd p tn o rio in g tsh e ip te le a IP to cu o d td h tyr1 n ve T S tp e icn a lu rn e rcra sto a in sle p e ca trtsh e T R -u P riso rg a m isn g S o n lq e a silrp te o n ce p e rA yG e rkY .e Maintenance 7 Maintenance 7.1 Servicing the TR-PS1 Programming Station May 2003 Revision 1.
TR-PS1 Textile Rental Programming Station User's Guide 8 Technical Data 8.1 Mechanical Characteristics Description Value Housing Plastic ABS UL 94-V0 Weight 1 kg (2.2 lbs.) Dimensions 255 x 216 x 20 mm (10 x 8½ x ¾ in.) Color Pantone P536 blue Protection Class IP 21 Operating Temperature 0°C to 55°C (32 °F to 131 °F) Storage Temperature -25°C to +60°C (-130 °F to 140 °F) Figure 14: Mechanical Dimensions (in millimeters) (Bottom View) 26/30 Revision 1.
Technical Data 8.2 Electrical Characteristics Description Value RF Power 0.25 W Operating Frequency 13.56 MHz Power consumption 165 mA under 5V Communication specification RS-232 Communication speed 9600 bit/s 8.3 Typical Performance Description Value Reading C210 C220 C270 50 mm. Writing C210 C220 C270 ??? mm.
TR-PS1 Textile Rental Programming Station User's Guide 9 Warranty Conditions 9.1 Warranty TAGSYS warrants that this Product shall comply with the functional specifications set forth herein for a period of one year from the date of delivery to the Buyer. This warranty is valid for the original Buyer of the Product and is not assignable or transferable to any other party.
Warranty Conditions 9.2.1 General Provisions This warranty sets forth the full extent of TAGSYS responsibility regarding the Product. In any event, TAGSYS warranty is strictly limited to (at TAGSYS’ sole option) the replacement or refund of the Products purchase price to TAGSYS, of Products considered as defective by TAGSYS.
TR-PS1 Textile Rental Programming Station User's Guide TAGSYS Product Return Form Customer Profile: Company:…………………………………………… Address:…………………………………...…...…… ………………………………………………………. City & State:……………...………………………. Zip Code:…………………………………………… Country:…………………………………………….. Contact Name:……………………………………… Contact e-mail: ……………………………………… Contact Phone:…………………………………… Contact Fax:……………………………………….. Order identification: Product Name:…………………………………….. Order Number (OEF):.…………………………… Invoice Number:……………………………...