Medio P101-Ethernet User's Guide Revision 2.
Medio P101-Ethernet Publishing Information Disclaimer and Limitation of Liability All information herein is either public information or is the property of and owned solely by TAGSYS who shall have and keep the sole right to file patent applications or any other kind of intellectual property protection in connection with such information.
Read This First Read This First Welcome to the TAGSYS range of products operating at the 13.56 MHz frequency. This range of products is used to implement high-quality RFID systems for demanding applications. This document provides information about how to install and use the Medio P101-Ethernet reader. Audience This document requires familiarity with RFID technology. It is intended for people in charge of installing and using the product.
Medio P101-Ethernet Quality Issues TAGSYS implements stringent quality controls at all stages of its manufacturing process. However, should you find a defect with this product, please notify your TAGSYS Quality Service representative using the dedicated Product Return Form. Telephone: Fax: 4/41 +33 (0)4 91 27 57 36 +33 (0)4 91 27 57 02 Revision 2.
Read This First Table of Contents PUBLISHING INFORMATION __________________________________________________________ 2 DISCLAIMER AND LIMITATION OF LIABILITY __________________________________________________ 2 READ THIS FIRST ____________________________________________________________________ 3 AUDIENCE ____________________________________________________________________________ 3 CONVENTIONS _________________________________________________________________________ 3 IF YOU NEED ASSISTANCE _______________
Medio P101-Ethernet 4.3.2 WINDOWS XP USB DRIVERS INSTALLATION __________________________________________ 24 5 PX EXPLORER ___________________________________________________________________ 25 5.1 INSTALLING PX EXPLORER _________________________________________________________ 25 5.2 RUNNING PX EXPLORER ___________________________________________________________ 27 5.2.1 USB COMMUNICATION ___________________________________________________________ 27 5.2.
For Your Safety 1 For Your Safety 1.1 General Use The Medio P101-Ethernet is designed to be reliable and to provide years of trouble-free service. Please observe the following general tips: Take care not to scratch the device. Keep the device clean. When working with the device, use only TAGSYS-approved accessories. This device is not waterproof and should not be exposed to rain or moisture. Under extreme conditions, water may enter the circuitry. Protect the device from extreme temperatures.
Medio P101-Ethernet 1.3 Important Safety Information 1.3.1 Operating Environment When connecting the device or any accessory to another device, read its user’s guide for detailed safety instructions. Do not connect incompatible products. To avoid contact with electrical current: • Never install electrical wiring during an electrical storm. • Never install an ethernet connection in wet locations unless that connector is specifically designed for wet locations.
Certification 2 Certification 2.1 Occupational Health and Safety Notices TAGSYS Medio P101-Ethernet reader has been designed and tested to be in conformity with the European Standard EN 50364 “Limitation of human exposure to electromagnetic fields from devices used in Electronic Article Surveillance (EAS), Radio Frequency Identification (RFID) and similar applications” in conjunction with the European Standard EN 50357 describing how to evaluate the exposure level. 2.
Medio P101-Ethernet 2.2.2 FCC ID Cross Reference Table It is the responsibility of the TAGSYS Partner to install the Medio P101-Ethernet as described in the table below, taking care of only installing the right antenna configuration with the right power settings. Antenna Configuration 10/41 Outside Dimension Channel Setting Max.
Certification 2.2.3 In USA (FCC Directive) The Medio P101-Ethernet has been designed to comply with Part 15 of the FCC Rules. Furthermore typical configurations based on the use of Single Antenna like Aero LB at 1W, LW 1 at 1W, Aero LF SHD at 1W and LSA 4 at 1 W, have been successfully tested with Part 15 of the FCC rules (FCC ID Numbers are listed on all system-mounted TAGSYS Antennas).
Medio P101-Ethernet 2.2.4 In Canada To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p) is no more than that permitted for successful communication. This device has been designed to operate with the antennas listed below, and having a maximum gain of -35 dBi. Antenna not included in this list or having a gain greater than -35 dBi are striclly prohibited for use with this device.
Introduction 3 Introduction 3.1 Product Description The Medio P101-Ethernet is a Medium Range 13.56 MHz RFID reader designed for Library, Textile Rental and I&L applications. The Medio P101-Ethernet has been designed to be used in combination with Aero LB, LW 1, Aero LF SHD and LSA 4 antennas that comply with FCC and CE rules. The Medio P101-Ethernet can decode C210, C220, C240, C320, C370(ISO 15693), C270(ICode1)and I-Code ePC and I-Code UID tags.
Medio P101-Ethernet 3.
Installing the Reader 4 Installing the Reader This section describes how to install the Medio P101-Ethernet reader. 4.1 Reader Connections 4.1.
Medio P101-Ethernet • I/O connector #1 #3 #5 #2 #4 Table 2: J3 Wiring Pin number 1 Signals 2 Output Supply output (12V with 470 Ω serial resistor) 3 Universal input 4 Ground 5 Ground 4.1.2 Rear Panel The rear panel is dedicated to power supply and communication connectors. Connector to Ethernet module Figure 3: Rear panel USB connector 12V DC Power supply connector J2 Reset button for Ethernet module only 16/41 Revision 2.
Installing the Reader • Ethernet module connector A shielded RJ 45 connector (Please refer to the Ethernet network cabling rules) • Power supply connector J2 2.5mm Jack type (positive connection on the center pin) • Reset button Reset button only used for Ethernet module (Please see Chapter 4.2 for more details) • USB connector USB connector type B When USB communication link is active (plugged and powered), the Ethernet module is turned off. 4.
Medio P101-Ethernet 4.2.
Installing the Reader • Reset Procedure To reset the Ethernet module 2 procedures are available: - Reboot the device: it is used to reinitialize the communication with your network. - Reset the device to TAGSYS default factory settings: it is used when you can no more communicate with the reader due to wrong WIFI settings. Both reset procedures are available by software via the WEB or TELNET interface.
Medio P101-Ethernet • Safety Statements To avoid contact with electrical current: - Never install electrical wiring during an electrical storm - Never install an Ethernet connection in wet locations unless that connector is specifically designed for wet locations - Use caution when installing or modifying Ethernet lines - Do not place Ethernet wiring or connections in any conduit, outlet or junction box containing electrical wiring - Installation of inside wire may bring you close to electrical
Installing the Reader You can now configure your Ethernet network to link the reader or follow the ADDP procedure to change the basic network IP settings. If you decide to configure your Ethernet network to meet the default settings of the reader, you can check your system is operational by pinging the reader using then “ping 192.168.0.2” MSDOS command prompt. 4.2.3 ADDP procedure (Advanced DigiConnect Discovery Device) Firewalls may block ADDP broadcast protocol.
Medio P101-Ethernet Select the correct Static IP, Subnet mask and Default Gateway or check the automatic setting in case a DHCP protocol is available on your network. Then, click Save. The reader starts to rebooting and the window closes. Back to the main window, double-click once again on the device. The WEB interface opens in the Internet Explorer browser (caution to the proxy settings of your internet browser connection, it must be set to allow access to this device).
Installing the Reader 4.3 Communicate with the USB Interface At first connection to the PC USB port, Windows® will detect the TAGSYS Medio P101-Ethernet reader and will ask you for drivers installation. USB drivers are located into the USB Drivers folder on the product CD-Rom. Two drivers must be installed: - The first one is the direct driver, which provides direct access to USB device via a dynamic link library (DLL). - The second one is the virtual COM port (VCP) driver.
Medio P101-Ethernet Power up and connect your Medio P101-Ethernet to a spare USB port on your PC. This should bring up a “Building Driver Information Database” followed by the Windows Add New Hardware Wizard. Select “Search for the best driver for your device” and then click “Next” Select “Specify a location” and click the Browse button to select the USB Drivers folder on the Product CR-Rom.
Px Explorer 5 Px Explorer The Medio P101-Ethernet reader is delivered with the Px Explorer software tool intended to easily setup the reader, test it and perform reading and writing operations according to the antenna and type of tag to be used. In addition, Px Explorer can display additional information such as the Product Reference and Firmware version and revision. This section describes how to start with Px Explorer. 5.
Medio P101-Ethernet Once the correct folder is selected, click “Next” Click “Next” to start the installation process. A shortcut will be created on your desktop and a program group will be created in the start menu. 26/41 Revision 2.
Px Explorer 5.2 Running Px Explorer 5.2.1 USB Communication Before launching Px Explorer be sure which COM port number is assigned to the TAGSYS Medio P101-Ethernet reader. Open the Device Manager and select “View > Devices by type”. The COM port number is assigned to the Medio P101. Power up the Medio P101-Ethernet and connect the USB cable to both your PC and the Medio P101-Ethernet. Run Px Explorer. If the following window is displayed click yes.
Medio P101-Ethernet Enter the correct reader IP address. Check the port number value and change it to the correct value in case the default raw TCP port value of the Medio P101-Ethernet reader has been modified. Set the STX setting mode to Fast to increase performances and click OK. 5.3 Reading and Writing a Tag Px Explorer includes a Wizard function used to guide you each step of how to read or program a tag.
Px Explorer For more details concerning Px Explorer select the info menu and click Help (CTRL+H) to display the Px Explorer User’s Guide. 5.4 Downloading a firmware Use Px Explorer to download a new firmware. When a communication is established with the reader, click on the upgrade firmware button By default Library firmware is already loaded. The firmware upgrade can be done either using the USB or Ethernet communication interface. The flasher window pops up.
Medio P101-Ethernet Select the firmware you want to download. Standard firmwares are: Firmware File Name Key Library LF12039xx.bin Medio P101 Industry and Logistics (I&L) LF12040xx.bin Medio P101 Textile Rental LF12041xx.bin Medio P101 Compatible chips C220 C320 C370 (ISO 15693) C270 (I-Code 1) C370 (ISO 15693) ePC UID C210 C240 C270 (I-Code 1) C370 (ISO 15693) Verify the Key of the firmware to be able to download it.
Stand-alone Mode 6 Stand-alone Mode Stand-alone Mode is designed to use the reader without using any command set. While in this mode, the reader is limited to tag reading. The reader sends the tag ID to the Host System using ASCII protocol via the Reader-to-Host interface. ASCII protocol is used in order to provide hexadecimal data that can be read by a variety of terminal programs (e.g. Microsoft® HyperTerminal). 6.1 Stand-alone Mode Features Table 3 lists the available Stand-alone mode features.
Medio P101-Ethernet Optional Optional C240 2 to 16 characters C220 2 to 10 characters C270 2 to 16 characters C320 2 to 16 characters C370 (ISO 2 to 16 characters 15693) ePC 2 to 24 characters UID 2 to 10 characters Optional Required End of Message String End of Text ID Chip Description String 2 to 16 characters (0x03) 1 character TR-P101 C210 (Default) 0 to 16 characters Size 0 to 16 characters “TAGSYS-“ Chip name (Default) 0 to 16 characters (0x02) 1 ch
Stand-alone Mode 6.1.3 Trigger Input When the trigger capability is enabled, a trigger state is used to start and stop the RF scanning. The trigger is connected to the input of the reader. Depending on the reply settings of the trigger, the ASCII message can be sent during the trigger activity (Repeated Read mode and Read Once mode are available) or at the end of the trigger.
Medio P101-Ethernet 6.2.1 Using Px Explorer Run the Px Explorer software. In the Settings menu, select General Reader Settings Enable Standalone mode at next power on 6.3 Disabling Stand-alone Mode The Medio P101-Ethernet can be reset in Standard mode in one of two ways as described below: • Use the Px Explorer software provided with the reader and click Yes when the following window is displayed • Send the 'S' character using a console interface (for example, HyperTerminal). 34/41 Revision 2.
Connecting Peripheral Devices 7 Connecting Peripheral Devices 7.1 Using the Universal Input pin The reader input can be driven by a voltage source from 0V up to 25V referring to the input ground. A relay (open chain transistor, switch…) can also be used to connect the input pin and its ground. - Low level input voltage is defined to be in the range of 0 to 1.5V - High level input voltage is defined to be in the range of 3 to 25V 7.
Medio P101-Ethernet Example: Connecting a load using an external power V The external power must be less than 25V Pin 1 Pin 4 7.3 I/O Electrical Signal Requirements Table 7 provides the electrical DC characteristics. Table 7: I/O Interface Pins - Electrical Characteristics Parameters Conditions Min. Typ. Max. Unit Input Voltage Low 0 2 V Input Voltage High 3 25 V 6 A Output Current 36/41 Revision 2.
Technical Specifications 8 Technical Specifications Table 8: Medio P101-Ethernet Technical Specifications Reference Size (L x W x H) Medio L-P101 154 x 84 x 38 mm (TOPTEC 154F) Weight 200 g DC power 12 VDC +/- 10% Typical C210 C240 C220 (Folio 20) C320 (Folio 320) ISO 15693 (Folio 370) EPc UID Chip compatibility (depending on downloaded firmware type) USB 1.1 Ethernet (Raw TCP) Communication interface RF Output Power 1.2 W Typical Power consumption 4.
Medio P101-Ethernet 9 Electrical Characteristics This chapter provides information about AC and DC characteristics for all pins. It also gives timing characteristics for the different interfaces. 9.1 Absolute Maximum Ratings Parameter Value Ambient Operating Temperature 0°C to +55°C Storage Temperature -20°C to +70°C Supply Voltage with respect to GND 25 V Total Power Dissipation 4.5 W Total Power Dissipation on Antenna 1.2 W 9.2 DC Characteristics Value Description Max. Typ. Min.
Warranty Conditions 10 Warranty Conditions 10.1 Warranty TAGSYS warrants that this Product shall comply with the functional specifications set forth herein for a period of one year from the date of delivery to the Buyer. This warranty is valid for the original Buyer of the Product and is not assignable or transferable to any other party.
Medio P101-Ethernet 10.2.1 General Provisions This warranty sets forth the full extent of TAGSYS responsibility regarding the Product. In any event, TAGSYS warranty is strictly limited to (at TAGSYS’ sole option) the replacement or refund of the Products purchase price to TAGSYS, of Products considered as defective by TAGSYS.
Warranty Conditions Product Return Form Customer Profile: Company: ................................................................ Address: .................................................................. ................................................................................. ................................................................................. City & State:............................................................. Zip Code: ......................................................